Ei Electronics Ei 105R Optical Product Manual

Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
Model Ei 105R Optical
High sensitivity – responds to all standard fires Senses smoke using the light scatter principle,
giving a quick response to visible smouldering fires
Supply voltage 10.2 to 14 volts Relay Contacts (Normally open and closed) Interconnect up to 12 alarms Test button Kitemarked to BS5446-1:2000 5 year guarantee
Product Description
The Ei105R is an Optical Smoke Alarm that that is designed to operate with suitable 12 volt control panels and to provide a loud local alarm.
Optical smoke alarms use the light scatter principle to detect smoke particles entering the optical chamber within the alarm.
Optical sensing technology gives a rapid response to visible smouldering fires.
The Ei105R is easily installed and comes supplied with all necessary screw fixings.
Relay contacts (normally open and closed supplied) are available for triggering the panel itself and its associated ancillary products, such as extra loud sirens, magnetic door holders, etc.
The alarms can be interconnected so that when one alarm senses fire, all the units located throughout the premises sound.
Operation
The smoke detector will activate the built in sounder
upon sensing smoke particles
The smoke detector will automatically reset itself
and silence the sounder when smoke particles are no longer present in the sensing chamber
The built in sounder will provide a minimum sound
output of 85dB at 3m
In “Test” button will perform a self test and sound
the horn (it may take up to 10 seconds)
Interconnect up to 12 other alarms (9V ionisation,
optical or heat) when one senses smoke, all alarm. Helps ensure warning will be heard throughout the house
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053 Email. eielectronics@eiltd.ie Web: www.eielectronics.com
Model Ei105R Optical
Installation & Placement
Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector Please consult the Instruction Leaflet supplied with the Ei105R for detailed
instructions as to how to correctly install and position the smoke detector
Important Precaution:
Do not install the actual smoke/heat alarm itself in new or renovated buildings until all work is completed (including floor coverings) and the building has been fully cleaned. (Excessive dust and debris from building work can contaminate the smoke chamber and cause problems, and it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a dust cover (eg. a plastic bag), until all cleaning is finished..
Technical Specification
Sensor Optical, uses light scatter from
smoke particles
Sensitivity: Complies with BS 5446 1: 2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and horn.
Ambient Light: Chamber housing design
overcomes problems with stray light.
Supply Voltage: 12V control panel
Alarm: Piezoelectric horn
in unit
Alarm Sound Output: 85dB (minimum) at 3m
Temperature Range: 0 to 40°C
Humidity Range: 0% to 90% Relative Humidity
Fixing: Screw fixings supplied
Plastic material: UL94HB flame retardant Dimensions: 145 x 120 x 45 mm Weight: 181 grams Warranty: 5 year (limited) warranty Approvals: Kitemarked to BS5446-1:2000, CE
Approved
Specifications are subject to change