EIC SFT4, SFT5, SFT6, SFT7, SFT8 Datasheet

...
SFT1 - SFT9
SUPER FAST RECTIFIER DIODES
FEATURES :
MECHANICAL DATA :
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25
°
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
PRV : 50 - 1000 Volts Io : 2.5 Amperes
* High current capability * High surge current capability * High reliability * Low reverse current * Low forward voltage drop * Super fast recovery time
* Case : D2A Molded plastic * Epoxy : UL94V-O rate flame retardant * Lead : Axial lead solderable per MIL-STD-202, Method 208 guaranteed * Polarity : Color band denotes cathode end * Mounting position : Any * Weight : 0.645 gram
D2A
0.161 (4.1)
0.154 (3.9)
0.040 (1.02)
0.0385 (0.98)
Dimensions in inches and ( millimeters )
1.00 (25.4) MIN.
0.284 (7.2)
0.268 (6.8)
1.00 (25.4) MIN.
RATING
Maximum Recurrent Peak Reverse Voltage V Maximum RMS Voltage V Maximum DC Blocking Voltage V Maximum Average Forward Current
0.375"(9.5mm) Lead Length Ta = 55 °C I Peak Forward Surge Current
8.3 ms. Single half sine wave Superimposed on rated load (JEDEC Method) I Maximum Peak Forward Voltage at IF = 2.5 A. V Maximum DC Reverse Current Ta = 25 °C I at Rated DC Blocking Voltage Ta = 100 °C I Maximum Reverse Recovery Time ( Note 1 ) Typical Junction Capacitance ( Note 2 ) C Junction Temperature Range T Storage Temperature Range T
SYMBOL SFT1 SFT2 SFT3 SFT4 SFT5 SFT6 SFT7 SFT8 SFT9 UNITS
RRM
RMS
DC
F(AV)
FSM
F
R
R(H)
Trr
J
J
STG
50 100 150 200 300 400 600 800 1000 Volts 35 70 105 140 210 280 420 560 700 Volts 50 100 150 200 300 400 600 800 1000 Volts
Notes :
( 1 ) Reverse Recovery Test Conditions : IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A. ( 2 ) Measured at 1.0 MHz and applied reverse voltage of 4.0 V
DC
2.5 Amps.
100 Amps.
0.95 1.4 1.7 Volts 5
50 35 ns 50 pf
- 65 to + 150
- 65 to + 150
A
µ
A
µ
C
°
C
°
UPDATE : APRIL 23, 1998
RATING AND CHARACTERISTIC CURVES ( SFT1 - SFT9 )
+
2.0
1.5
1.0
0.5
2.5
10
1.0
100
0
07550250.11080
1.0
0.1
100
140
0204060120
AVERAGE FORWARD OUTPUT
REVERSE CURRENT, MICROAMPERES
+ 0.5 A0- 0.25 A
1 cm
FIG.1 - REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
50
50 Vdc
(approx)
NOTES : 1. Rise Time = 7 ns max., Input Impedance = 1 megaohm, 22 pF.
2. Rise time = 10 ns max., Source Impedance = 50 ohms.
3. All Resistors = Non-inductive Types.
D.U.T.
1
10
PULSE
GENERATOR
( NOTE 2 )
OSCILLOSCOPE
( NOTE 1 )
- 1.0 A
Trr
SET TIME BASE FOR 15 ns/cm
FIG.2 - DERATING CURVE FOR OUTPUT FIG.3 - MAXIMUM NON-REPETITIVE PEAK RECTIFIED CURRENT FORWARD SURGE CURRENT
125
CURRENT, AMPERES
60Hz RESISTIVE OR INDUCTIVE LOAD
0 25 50 75 100 125 150 175 1 2 4 6 10 20 40 60 100
CURRENT, AMPERES
PEAK FORWARD SURGE
AMBIENT TEMPERATURE, ( °C)
8.3 ms SINGLE HALF SINE WAVE Ta = 50 °C
NUMBER OF CYCLES AT 60Hz
FIG.4 - TYPICAL FORWARD CHARACTERISTICS FIG.5 - TYPICAL REVERSE CHARACTERISTICS
100
FORWARD CURRENT, AMPERES
0.01 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Pulse Width = 300 µs
2% Duty Cycle
TJ = 25 °C
SFT1 - SFT4
SFT7 - SFT9
FORWARD VOLTAGE, VOLTS
TJ = 100 °C
SFT5 - SFT6
TJ = 25 °C
0.01
PERCENT OF RATED REVERSE
VOLTAGE, (%)
Loading...