E.F. Johnson Company 4100 SERIES Operating Manual

Rhein Tech Laboratories Report #: 2004209 360 Herndon Parkway FCC ID: ATH2424130 Suite 1400 Model: 242-413x-xxx Herndon, VA 20170 Standards: FCC Part 90 & IC RSS-119 http://www.rheintech.com
Date: December 19, 2004
APPENDIX K: USER’S MANUAL
Please see the following Operator’s Manual.
OPERATING
MANUAL
4100
4100 SERIES PORTABLE RADIO
APCO Project 25
– Conventional – Trunked
®
SMARTNET
SmartZone
Analog (FM)
/
®
DIGITAL/ANALOG PORTABLE RADIO
Conventional
VHF UHF
700/800 MH
Part No. 242-41xx-xxx
Z
Part Number 002-4100-xxxx
December 2004
4100 SERIES PORTABLE
OPERATING MANUAL
APCO PROJECT 25 CONVENTIONAL
APCO PROJECT 25 TRUNKED
SMARTNET
®
/SmartZone
®
ANALOG (FM) CONVENTIONAL
VHF/UHF/800 MHz
Copyright© 2004 by the E.F. Johnson Company
The E.F. Johnson Company, which was founded in 1923, provides wireless communication systems solutions for public safety, government, and commercial customers. The company designs, manufactures, and markets conventional and trunked radio systems, mobile and portable subscriber radios, repeaters, and Project 25 digital radio products. EFJohnson is a wholly owned subsidiary of EFJ, Inc.
Viking Head/EFJohnson logo, PCConfigure Johnson Company. SMARTNET vate Conversation company and/or product names used in this manual are trademarks and/or registered trade­marks of their respective manufacturer. The IMBE™ voice coding technology embodied in this product is protected by intellectual property rights including patent rights of Digital Voice Systems, Inc.
, and Private Conversation II™ are trademarks of Motorola, Inc. All other
®
, SmartZone®, SecureNet™, Call Alert™, Enhanced Pri-
, and Call Guard® are trademarks of the E.F.
LAND MOBILE PRODUCT WARRANTY - The manufacturer’s warranty statement for this product is available from your product supplier or from E.F. Johnson Company, 1440 Corporate Drive, Irving, TX 75038-2401. Phone toll free 1-800-328-3911.
Information in this manual is subject to change without notice.
TABLE OF CONTENTS
TABLE OF CONTENTS
SAFETY INFORMATION
Federal Communications Commission Regulations 6
Compliance with RF Exposure Standards. . . . . . . .6
RF Exposure Compliance and Control Guidelines
and Operating Instructions. . . . . . . . . . . . . . . . . . . .7
Contact Information. . . . . . . . . . . . . . . . . . . . . . . . .7
Electromagnetic Interference. . . . . . . . . . . . . . . . . .7
Usage Compatibility . . . . . . . . . . . . . . . . . . . . . . . .7
Battery Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1 FEATURES
1.1 General Features . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1.2 Conventional Features. . . . . . . . . . . . . . . . . . . . . . .8
1.3 SMARTNET/SmartZone Features . . . . . . . . . . . . .8
1.4 Project 25 Trunked Features . . . . . . . . . . . . . . . . . .9
2 CONTROLS AND DISPLAY
2.1 Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . .10
2.2 Top Panel Controls . . . . . . . . . . . . . . . . . . . . . . . .11
2.3 Side Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.4 Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3 GENERAL OPERATION
3.1 Turning Power On and Setting Volume . . . . . . . .13
Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Standard and Soft Power Down . . . . . . . . . . . . 13
Setting Volume Level. . . . . . . . . . . . . . . . . . . . 13
3.2 Power-Up Password. . . . . . . . . . . . . . . . . . . . . . . .13
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Password Features. . . . . . . . . . . . . . . . . . . . . . . 14
3.3 Zone and Channel Select . . . . . . . . . . . . . . . . . . . .14
3.4 Low Battery Indication . . . . . . . . . . . . . . . . . . . . .15
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Battery Charging. . . . . . . . . . . . . . . . . . . . . . . . 16
3.5 Backlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3.6 Keypad Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3.7 Setting Squelch . . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.8 Transmit Disable . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.9 Radio Operating Modes. . . . . . . . . . . . . . . . . . . . .17
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Conventional Mode. . . . . . . . . . . . . . . . . . . . . . 17
SMARTNET/SmartZone Mode . . . . . . . . . . . . 17
P25 Trunked Mode . . . . . . . . . . . . . . . . . . . . . . 18
Systems, Channels, and Zones . . . . . . . . . . . . . 18
4 RADIO-WIDE FEATURES
4.1 Option Switches . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.2 Menu Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3 Time-Out Timer . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.4 Home Zone/Channel Select . . . . . . . . . . . . . . . . . 22
4.5 Power Output Select. . . . . . . . . . . . . . . . . . . . . . . 22
4.6 Alert Tone Select . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.7 Surveillance Mode . . . . . . . . . . . . . . . . . . . . . . . . 22
4.8 Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Priority Scanning. . . . . . . . . . . . . . . . . . . . . . . . 23
Radio Wide Scanning . . . . . . . . . . . . . . . . . . . . 23
Scan Hold Time. . . . . . . . . . . . . . . . . . . . . . . . . 23
Transmitting in the Scan Mode . . . . . . . . . . . . . 24
Nuisance Channel Add/Delete. . . . . . . . . . . . . . 24
4.9 Scan Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Priority Scan Lists . . . . . . . . . . . . . . . . . . . . . . . 24
Radio Wide Scan Lists. . . . . . . . . . . . . . . . . . . . 26
5 CONVENTIONAL MODE FEATURES
5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.2 Monitoring Before Transmitting . . . . . . . . . . . . . 27
5.3 Monitor Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.4 Busy Channel Lockout . . . . . . . . . . . . . . . . . . . . . 27
5.5 Call Guard Squelch. . . . . . . . . . . . . . . . . . . . . . . . 28
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Call Guard Squelch Enable/Disable . . . . . . . . . 28
Tone Call Guard Squelch. . . . . . . . . . . . . . . . . . 28
Digital Call Guard Squelch . . . . . . . . . . . . . . . . 28
Selective Squelch Code Select. . . . . . . . . . . . . . 29
5.6 Penalty Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.7 Conversation Timer . . . . . . . . . . . . . . . . . . . . . . . 29
5.8 Repeater Talk-Around . . . . . . . . . . . . . . . . . . . . . 30
5.9 Displaying Transmit/Receive Frequency . . . . . . . 30
5.10 Emergency Alarm and Call . . . . . . . . . . . . . . . . . 30
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Emergency Alarms . . . . . . . . . . . . . . . . . . . . . . 30
Emergency Calls . . . . . . . . . . . . . . . . . . . . . . . . 31
Emergency Man-Down Feature. . . . . . . . . . . . . 31
5.11 Conventional Mode Scanning
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Transmitting in Scan Mode . . . . . . . . . . . . . . . . 32
Priority Channel Sampling . . . . . . . . . . . . . . . . 32
5.12
Standard Conventional Calls. . . . . . . . . . . . . 33
5.13 DTMF/ANI Signaling. . . . . . . . . . . . . . . . . . . . . . 33
5.14 Single Tone Encoder . . . . . . . . . . . . . . . . . . . . . . 33
5.15 MDC1200 Compatibility . . . . . . . . . . . . . . . . . . . 34
. . . . . . . . . . . . . . 31
3
TABLE OF CONTENTS
5.16 Clone Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Wireless Cloning. . . . . . . . . . . . . . . . . . . . . . . . 34
Cloning Procedure . . . . . . . . . . . . . . . . . . . . . . 34
5.17 Project 25 Mode Features . . . . . . . . . . . . . . . . . . .35
Unit ID Code. . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Group ID Code . . . . . . . . . . . . . . . . . . . . . . . . . 35
Network Access Code. . . . . . . . . . . . . . . . . . . . 35
P25 Group Calls . . . . . . . . . . . . . . . . . . . . . . . . 35
P25 Unit Calls. . . . . . . . . . . . . . . . . . . . . . . . . . 35
P25 Conventional Telephone Calls. . . . . . . . . . 36
Call Alert. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Messaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Status Messaging . . . . . . . . . . . . . . . . . . . . . . . 38
P25 Packet Data . . . . . . . . . . . . . . . . . . . . . . . . 38
5.18 Keypad Programming . . . . . . . . . . . . . . . . . . . . . .38
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Menu Description . . . . . . . . . . . . . . . . . . . . . . . 39
Zone Password . . . . . . . . . . . . . . . . . . . . . . . . . 39
Zone Change Parameter . . . . . . . . . . . . . . . . . . 39
Channel Change Parameter. . . . . . . . . . . . . . . . 40
System Parameters . . . . . . . . . . . . . . . . . . . . . . 40
Channel Parameters . . . . . . . . . . . . . . . . . . . . . 40
6 SMARTNET/SMARTZONE/P25
TRUNKED FEATURES
6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
6.2 Analog and Digital Operation . . . . . . . . . . . . . . . .42
6.3 Viewing Unit ID . . . . . . . . . . . . . . . . . . . . . . . . . .4 2
6.4 Standard Group Calls. . . . . . . . . . . . . . . . . . . . . . .42
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Placing a Standard Group Call . . . . . . . . . . . . . 42
Receiving a Standard Group Call . . . . . . . . . . . 42
6.5 Private (Unit-To-Unit) Calls . . . . . . . . . . . . . . . . .43
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Placing an Enhanced Private Conversation Call 43 Placing a Standard Private Conversation Call . 44
Receiving a Private Call (All Types) . . . . . . . . 45
6.6 Telephone Calls . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Placing a Telephone Call . . . . . . . . . . . . . . . . . 45
Answering a Telephone Call. . . . . . . . . . . . . . . 46
6.7 Call Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Answering a Page . . . . . . . . . . . . . . . . . . . . . . . 46
Initiating a Page . . . . . . . . . . . . . . . . . . . . . . . . 47
6.8 Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 7
6.9 Sending Status Conditions. . . . . . . . . . . . . . . . . . .47
6.10 Emergency Alarm and Call . . . . . . . . . . . . . . . . . .47
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Emergency Alarms . . . . . . . . . . . . . . . . . . . . . . 48
Emergency Calls . . . . . . . . . . . . . . . . . . . . . . . . 48
Emergency Man-Down Feature. . . . . . . . . . . . . 49
6.11 Failsoft Operation. . . . . . . . . . . . . . . . . . . . . . . . . 49
6.12 SMARTNET/Smartzone/P25 Trunked Scanning Fea­tures49
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Priority Talk Group Sampling . . . . . . . . . . 49
6.13 Dynamic Regrouping . . . . . . . . . . . . . . . . . . . . . . 50
6.14 SmartZone and P25 Trunked Unique Features. . . 50
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Busy Override . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Site Trunking. . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Determining Current Site and Searching For New
Site 51
Locking/Unlocking a Site . . . . . . . . . . . . . . . . . 51
ZoneFail Site Lock . . . . . . . . . . . . . . . . . . . . . . 51
P25 Wide Area Scan . . . . . . . . . . . . . . . . . . . . . 51
7 MISCELLANEOUS
7.1 Supervisory Tones . . . . . . . . . . . . . . . . . . . . . . . . 53
7.2 Error Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.3 System Operator Programming . . . . . . . . . . . . . . 55
7.4 Speaking Into Microphone . . . . . . . . . . . . . . . . . . 56
7.5 Operation At Extended Range . . . . . . . . . . . . . . . 56
7.6 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
7.7 Radio Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
8 DETERMINING AVAILABLE OPTIONS
8.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
8.2 Upgrading A Radio With New Options . . . . . . . . 57
8.3 Using PCConfigure To Determine Options . . . . . 57
9 PASSWORD DESCRIPTION
9.1 New Password Enhancements . . . . . . . . . . . . . . . 59
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
9.2 Programming Passwords . . . . . . . . . . . . . . . . . . . 59
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Lost Passwords . . . . . . . . . . . . . . . . . . . . . . . . . 59
Changing Password . . . . . . . . . . . . . . . . . . . . . . 59
Password Entry Procedure. . . . . . . . . . . . . . . . . 59
9.3 Password Description. . . . . . . . . . . . . . . . . . . . . . 60
User (Power-On) Passwords . . . . . . . . . . . . . . . 60
Download/Upload Passwords . . . . . . . . . . . . . . 60
Master Password . . . . . . . . . . . . . . . . . . . . . . . . 60
9.4 Zone Password . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
4
TABLE OF CONTENTS
10 SECURE COMMUNICATION
(ENCRYPTION)
10.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Encryption Algorithms . . . . . . . . . . . . . . . . . . . 61
Encryption Available With Various Channel Types
61
FIPS and Non-FIPS Modes. . . . . . . . . . . . . . . . 61
10.2 Encryption Keys . . . . . . . . . . . . . . . . . . . . . . . . . .62
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Key and Algorithm IDs. . . . . . . . . . . . . . . . . . . 62
PID/SLN Key Management Modes . . . . . . . . . 62
Maintaining Keys in Memory. . . . . . . . . . . . . . 63
Encryption Key Select . . . . . . . . . . . . . . . . . . . 63
Encryption Key Erase. . . . . . . . . . . . . . . . . . . . 63
Encryption Icon Operation . . . . . . . . . . . . . . . . 63
10.3 Clear/Secure Strapping . . . . . . . . . . . . . . . . . . . . .6 3
Transmit Mode Options . . . . . . . . . . . . . . . . . . 63
Receive Mode Options. . . . . . . . . . . . . . . . 64
Talk Group Encryption Override . . . . . . . . . . . 64
10.4 OTAR (Over-The-Air Rekeying) . . . . . . . . . . . . .64
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Encryption Key Types . . . . . . . . . . . . . . . . . . . 65
Keysets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Crypto Groups . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Key Management Facility . . . . . . . . . . . . . . . . . 65
Message Number Period (MNP) . . . . . . . . . . . . 66
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
10.5 Radio Setup For Encryption. . . . . . . . . . . . . . . . . 68
General Encryption Setup . . . . . . . . . . . . . . . . . 68
Additional Setup For OTAR . . . . . . . . . . . . . . . 69
10.6 Radio OTAR Capabilities. . . . . . . . . . . . . . . . . . . 69
SEM 4100/53xx, Standard 41xx . . . . . . . . . . . . 69
UCM Equipped 4100. . . . . . . . . . . . . . . . . . . . . 70
OTAR Option Switches. . . . . . . . . . . . . . . . . . . 70
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
5
SAFETY INFORMATION
RF ENERGY EXPOSURE AWARENESS AND CONTROL INFORMATION, AND
OPERATIONAL INSTRUCTIONS FOR FCC OCCUPATIONAL USE REQUIREMENTS
Before Using Your Portable Two-Way Radio, Read This Important RF Energy Awar eness And Control Information And Operational Instructions To Ensure Compliance With The FCC’s RF Exposure Guidelines.
NOTICE: This radio is intended for use in occupa­tional/controlled conditions where users have full knowledge of their exposure and can exercise control over their exposure to meet FCC limits. This radio device is NOT authorized for general population, consumer, or any other use.
This two-way radio uses electromagnetic energy in the radio frequency (RF) spectrum to provide communications between two or more users over a distance. It uses radio frequency (RF) energy or radio waves to send and receive calls. RF ener gy is one form of electromagnetic energy. Other forms include, but are not limited to, electric power, sunlight and x-rays. RF energy, however, should not be confused with these other forms of electromagnetic energy, which when used improperly can cause biological damage. Very high levels of x-ra ys, for example, can damage tissues and genetic material.
Experts in science, engineering, medicine, health and industry work with organizations to develop stan­dards for exposure to RF energy. These standards provide recommended levels of RF exposure for both workers and the general public. These recommended RF exposure levels include substantial margins of protection. All two-way radios marketed in North America are designed, manufactured and tested to ensure they meet government established RF expo­sure levels. In addition, manufacturers also recom­mend specific operating instructions to users of two­way radios. These instructions are important because they inform users about RF energy exposure and provide simple procedures on how to control it. Please refer to the following web sites for more information on what RF energy exposure is and how to control your exposure to assure compliance with established RF exposure limits.
http://www.fcc.gov/oet/rfsafety/rf-faqs.html
http://www.osha.gov/SLTC/radiofrequencyradia-
tion/index.html
FEDERAL COMMUNICATIONS COMMISSION REGULATIONS
The FCC rules require manufacturers to comply with the FCC RF energy exposure limits for portable two-way radios before they can be marketed in the U.S. When two-way radios are used as a consequence of employment, the FCC requires users to be fully aware of and able to control their exposure to meet occupational requirements. Exposure awareness can be facilitated by the use of a product label directing users to specific user awareness information. Your EFJohnson two-way radio has a RF exposure product label. Also, your EFJohnson user manual, or product manual, or separate safety booklet includes information and operating instructions required to control your RF exposure and to satisfy compliance requirements.
COMPLIANCE WITH RF EXPOSURE STANDARDS
Your EFJohnson two-way radio is designed and tested to comply with a number of national and interna­tional standards and guidelines (listed below) for human exposure to radio frequency electromagnetic ene rgy. This radio complies with the IEEE and ICNIRP exposure limits for occupational/controlled RF exposure environ­ment at operating duty factors of up to 50% transmitting and is authorized by the FCC for occupational use only. In terms of measuring RF energy for compliance with the FCC exposure guidelines, your radio radiates measurable RF energy only while it is transmitting (during talking), not when it is receiving (listening) or in standby mode.
NOTE: The approved batteries supplied with this radio are rated for a 5-5-90 duty factor (5% talk-5% listen ­90% standby), even though this radio complies with the FCC occupational RF exposure limits and may operate at duty factors of up to 50% talk.
Your EFJohnson two-way radio complies with the following RF energy exposure standards and guidelines:
United States Federal Communications Commission,
Code of Federal Regulations; 47 CFR §§ 1.1307,
1.1310, 2.1091 and 2.1093
American National Standards Institute (ANSI) / Insti-
tute of Electrical and Electronic Engineers (IEEE) C95. 1-1992
6
SAFETY INFORMATION
Institute of Electrical and Electronic Engineers (IEEE)
C95.1-1999 Edition
RF EXPOSURE COMPLIANCE AND CONTROL GUIDELINES AND OPERATING INSTRUCTIONS
To control your exposure and ensure compliance with the occupational/controlled environment exposure limits, always adhere to the following procedures.
Guidelines
:
Do not remove the RF Exposure Label from the
device.
User awareness instructions should accompany the
device when it is transferred to other users.
Do not use this device if the operational requirements
described herein are not met.
Operating Instructions
:
Transmit no more than the rated duty factor of 50% of
the time. To transmit (talk), push the Push-To-Talk (PTT) but ton. T o rec eive calls, release the PTT button. Transmitting 50% of the time, or less, is important because this radio generates measurable RF energy exposure only when transmitting (in terms of measuring for standards compliance).
Hold the radio in a vertical position in front of face
with the microphone (and the other parts of the radio , including the antenna) at least one inch (2.5 cm) away from the nose. Keeping the radio at the proper distance is important because RF exposures decrease with distance from the antenna. The antenna should be kept away from eyes.
When worn on the body, always place the radio in an
EFJohnson approved clip, holder, holster, case, or body harness for this product. Using approved body­worn accessories is important because the use of EFJohnson or other manufacturer’s non-approved accessories may result in exposure levels which exceed the FCC’s occupational/controlled environ­ment RF exposure limits.
If you are not using a body-worn accessory and are not
using the radio in the intended use position in front of the face, then ensure the antenna and the radio are kept at least one inch (2.5 cm) from the body when trans­mitting. Keeping the radio at the proper distance is important because RF exposures decrease with increasing distance from the antenna.
Use only EFJohnson approved supplied or replace-
ment antennas, batteries, and accessories. Use of non-
EFJohnson approved antennas, batteries, and accesso­ries may exceed the FCC RF exposure guidelines.
For a list of EFJohnson approved accessories, see the
service manual or marketing accessory lists or contact the E.F. Johnson Company
CONTACT INFORMATION
Toll-Free: 1-800-328-3911 FAX: 972-818-0639 E-Mail: customerservice@efjohnson.com. You can also
e-mail a person directly if you know their first initia l/l ast name (example: jsmith@efjohnson.com).
You may also contact the Customer Service Depart­ment by mail. Please include all information that may be helpful in solving your problem. The mailing address is as follows:
E.F. Johnson Company Customer Service Department 1440 Corporate Drive Irving, TX 75038-2401
ELECTROMAGNETIC INTERFERENCE
This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this devi ce does not cause harmful interference. In addition, changes or modification to this equipment not expressly approved by the E.F. Johnson Company could void the user’s authority to operate this equipment (FCC Rules, 47CFR Part 15.19).
USAGE COMPATIBILITY
DO NOT operate it in areas that are sensitive to RF energy such as aircraft, hospitals, blasting sites, and fuel storage sites. Areas with potentially flammable atmo­spheres are usually , but not always, clearly posted. These may include gas stations, fuel and chemical storage and transfer stations, below deck on boats, and areas where the air contains flammable chemicals or particles such as grain dust or metal powders.
BATTERY DISPOSAL
Dispose of the nickel metal-hydride (NiMH) battery used by this radio in accordance with local regulations. DO NOT dispose of it in fire because it can explode. Also, do not short the terminals because it may become very hot.
7
SECTION 1 FEATURES
FEATURES
NOTE: The availability of many of the following features is controlled by factory coding of your radio, installed options, firmware version, and field programming. Refer to Section 8 for mor e information.
1.1 GENERAL FEATURES
The following operating modes are programmable:
– Conventional analog – Conventional Project 25 (digital) – Trunked Project 25 (digital) – SMARTNET
or digital)
/SmartZone® trunked (analog
Up to 32 zones with 16 channels each (512 channels
total) are standard.
Large graphic display with backlight
16-position channel select switch
3-position rotary option switch
Up to 9 (limited keypad) or 21 (DTMF keypad)
programmable option switches
Each option button programmable with a different
function for each operating mode (Conventional, SMARTNET/SmartZone, Trunked P25)
Menu mode
AES 256-bit FIPS 140-2 approved encryption
available on P25/digital channels
DES/DES-XL 64-bit encryption available on analog
channels, DES-OFB on digital channels (see Section 10).
Emergency calls for high priority system access
Priority (standard) and Radio W ide scan modes with
user programmable scan lists
User selectable high and low power output
Surveillance mode
Time-out timer
Keypad lock to prevent accidental key presses
Power up password to prevent unauthorized use.
Programmable and user adjustable tone volume
Programmable minimum volume level
Soft power down to prevent accidental power off
Operates on both wide and narrow band channels
1.2 CONVENTIONAL FEATURES
Up to 512 channels or talk groups programmable
Repeater talk-around
Carrier or Call Guard
squelch on analog channels, NAC and talk group IDs on P25 channels.
®
(CTCSS/DCS) controlled
Normal/selective squelch selectable by option
switch or menu
Monitor mode selectable by option switch or menu
Penalty and conversation timers
Dual priority channel sampling when scanning
(analog and digital channels)
Busy channel lockout (transmit disable on busy)
Unit calls on P25 channels
Telephone calls on P25 channels with overdial.
Cloning capability (wireless or using cable)
Emergency alarms and calls to alert a dispatcher of
an emergency condition.
Single tone encoder controllable by user on analog
channels
ANI (Automatic Number Identification) on analog
channels
MDC1200 ANI and Emergency Alert support.
Call Alert™ on P25 channels (send and receive
pages).
Predefined messages (up to 16) can be sent to a
dispatcher (P25 mode only)
Predefined status conditions (up to 8) can be sent to
a dispatcher (P25 mode only)
OTAR (Over-The-Air-Rekeying) compatible (P25
channels only).
Keypad programming with password access
(Federal Government users only)
1.3 SMARTNET/SMARTZONE FEATURES
Up to 512 talk groups programmable (channels
select talk groups)
Group, Enhanced Private Conversation™, standard
Private Conversation, and Telephone calls
Emergency alarms to alert a dispatcher of
emergency conditions
Emergency calls for high priority system access
Failsoft operation on a predefined conv en tional
channel if trunked system fails
Priority group calls detected while listening to other
group calls when scanning
Call Alert™ (send and receive pages)
Predefined messages (up to 16) can be sent to a
dispatcher
8
FEATURES
Predefined status conditions (up to 8) can be sent to
a dispatcher
Dynamic regrouping (dispatcher can automatically
gather users on a channel to receive a message)
Roaming (SmartZone only)
1.4 PROJECT 25 TRUNKED FEATURES
Up to 512 talk groups programmable (channels
select talk groups)
Group and Unit Calls
Telephone calls with overdial
Emergency alarms to alert a dispatcher of
emergency conditions
Emergency calls for high priority system access
Failsoft operation on a predefined conventional
channel if trunked system fails
Priority group calls detected while listening to other
group calls when scanning
Call Alert™ (send and receive pages)
Predefined status conditions (up to 8) can be sent to
a dispatcher
Dynamic regrouping (dispatcher can automatically
gather users on a channel to receive a message)
Roaming
9
SECTION 2 CONTROLS AND DISPLAY
CONTROLS AND DISPLAY
Figure 2-1 Front Panel Controls
2.1 FRONT PANEL CONTROLS
NOTE: The location of these controls is shown in Figure 2-1.
Microphone - The microphone is located behind the small opening shown in Figure 2-1. For best results, hold the radio 2-3 inches from you mouth and speak at a normal conversational level. Do not shout since it distorts your voice and does not increase range.
Display - This is a graphical LCD (Liquid Crystal Display). The display backlight can be programmed to turn on when any key is pressed or when the Backlight option switch is pressed or menu parameter selected (see Section 3.5).
Up/Down Switch - Selects zones when multiple zones are programmed (see Section 3.3). Pressing the upper part of the switch selects the next higher number and pressing the lower part selects the next lower number. This control also provides up/down select in the menu mode and in other modes when up/down select is required.
F1 - In menu mode (see Section 4.2), functions as a step back and exit switch. If menu mode is not used, it is a programmable option switch.
F2 - Selects the menu mode when that mode is enabled by programming. Also functions as an Enter or Select switch in the menu and other modes. If menu mode is not used, it is a programmable option switch.
F3, F4 - Programmable option switches.
10
CONTROLS AND DISPLAY
DTMF Keypad - The full keypad DTMF models include the 12 keys required to dial telephone and un it ID numbers.
Speaker - The radio speaker is located near the bottom of the front panel. When a speaker/microphone is used, it is automatically detected when the Opt Sel 1 line of the accessory connector is pulled low. The logic then automatically disables the internal speaker.
Channel Switch - This 16-position switch selects up to 16 channels in the current zone. Additional zones can be programmed to allow up to 512 channels to be selected by this switch. This control can be disabled as described in Section 3.3.
Rotary Option Switch - This is a three-position switch that can be programmed to control various options. The “A” position is “on” and the “B” and “C” positions are “off” (see Section 4.1). When this switch is programmed to select zones, “A” selects Zone 1, “B” Zone 2, and “C” Zone 3 if applicable.
Antenna Connector - Connection point for the antenna. Make sure the antenna is tight before using the radio.
Emergency Switch - This switch or some other option switch can be programmed as an Emergency switch to alert a dispatcher of an emergency condition. Refer to Sections 5.10 and 6.10 for more information. This switch can also be programmed for other functions.
Figure 2-2 Top Panel Controls
2.2 TOP PANEL CONTROLS
Multi-Function Indicator - Indicates the following conditions:
Steady R ed Flashing Red Steady G reen
- Transmitter keyed.
- Low battery in receive mode.
- Carrier detected in receive mode.
NOTE: This indicator is disabled if the Surveillance mode is programmed (see Section 4.7).
On-Off/Volume - Turning the knob clockwise turns power on and sets the volume level. Turning it coun­terclockwise to the detent turns power off. The minimum volume level can be set by programming. Soft power down can be programmed as described in Section 3.1.2, and the volume control can be disabled as described in Section 3.1.3.
2.3 SIDE CONTROLS
Figure 2-3 Side Controls and Jacks
PTT (Push-To-Talk) Switch - This switch is pressed to turn the transmitter on to transmit a message. It is then released to listen. Transmitting is indicated when the top panel indicator is constant red or is displayed (surveillance mode only, see Section 4.7).
Option Switches 1, 2, and 3 - Each of these switches can be programmed to control a specific function (see Section 4.1). In addition, they can be programmed for
11
CONTROLS AND DISPLAY
soft power down (see Section 3.1.2). These switches can also be temporarily disabled by the keypad lock feature (see Section 3.6) or permanently disabled.
Battery - To remove the battery, press the release button on the bottom and pivot the bottom of the battery outward.
Accessory Connector - Connection point for optional accessories such as a speaker/microphone or earphone. It is also the connection point for the computer when programming the radio or for data equipment when the P25 Packet Data feature is used (see Section 5.17.10).
2.4 DISPLAY
- When the scan or the scan list edit mode is
enabled, indicates that the displayed channel is a priority channel. If dual priority is used, indicates that it is a second priority channel.
2
- Low battery indication (see Section 3.4).
- Voice encryption is enabled or an encrypted
call is being received. This indication flashes when an encrypted call is received on a digital channel (see Section 10.2.7).
- Priority or radio wide scanning is enabled (see
Section 4.8).
- In the surveillance mode only, indicates that
the transmitter is keyed (see Section 4.7). This icon is displayed in place of the preceding scan mode icon when applicable. They do not conflict because the scan icon is not displayed in the transmit mode.
- Repeater talk-around is enabled (see
Section 5.8).
Figure 2-4 Graphical Display
The front panel display is shown above. Icons are typically shown in the upper part of the display and text messages in the lower part. The icons are as follows:
- When the scan or the scan list edit mode is
enabled, indicates that the displayed channel is in the scan list and scanned (see Section 4.8).
- The Monitor mode is enabled by the Monitor
option switch or menu parameter (see Section 5.3). The radio can also be programmed so this icon is displayed when the Normal mode is selected by the Normal/Selective function (see Section 5.5.2).*
- Keypad programming or another mode is
enabled which allows the user to edit radio parameters.
- An interconnect (telephone) call is in progress
(see Section 6.6).
- A Project 25 or SMARTNET/SmartZone
private (unit-to-unit) call is in progress.
12
SECTION 3 GENERAL OPERATION
GENERAL OPERATION
3.1 TURNING POWER ON AND SETTING
VOL UM E
3.1.1 POWER UP
Power is turned on and off by the top panel On­Off/Volume switch. When power is initially turned on, the following events occur:
The software version number is displayed.
A self test is performed.
The currently selected zone is displayed.
If a conventional P25 channel is selected, the
Individual ID of the radio is displayed.
If a SMARTNET/SmartZone or P25 Trunked
channel is selected, the Unit ID of the radio is displayed.
A tone sounds (if tones are enabled)
The selected channel alias is displayed continuously
when power-up is complete.
Programming determines if the radio powers up on the last selected zone or the pre-programmed home zone. Refer to Section 3.3 for information on the channel that is selected. The minimum volume level may be set by programming. This can prevent missed messages resulting from inadvertently turning the volume to an inaudible level.
3.1.2 STANDARD AND SOFT POWER DOWN
To turn power off, rotate the On-Off/Volume control counterclockwise until a click occurs. Power may remain on for an instant after turn-off occurs.
for the Up/Down volume function. When the buttons are used, the volume control function of the knob is disabled (it is still used to switch power). Volume buttons may be used instead of the knob, for example, if accidental turning of the volume knob is a problem.
When the volume control buttons are used, the number of steps (ticks) required to change the volume from the minimum level to maximum level is programmable for 1-50. For example, if “20” is programmed, there are 20 adjustment steps from minimum to maximum volume. Only one volume control button can be programmed if desired and wrap-around then occurs after the maximum or minimum level is selected.
The radio can also be programmed so that volume control is also be disabled by the Keypad Lock feature. Refer to Section 3.6 for more information.
The relative volume level can be determined by the position of the index on the volume knob or by a reference signal as follows:
If a key press tone is enabled, a short tone sounds
when a key is pressed.
If a conventional channel is selected and the
Monitor option switch or menu parameter is programmed, pressing that switch unsquelches the receiver and either voice or background noise is heard (see Section 5.3). If a SMARTNET/Smart­Zone or P25 Trunked channel is selected, the receiver cannot be manually unsquelched.
A soft power down feature can be programmed to prevent radio power from being turned off by acciden­tally turning the on-off/volume control. Any side button can be programmed for this function in addition to its normal function. Then for power to turn off, this button must be pressed during or after power is turned off in the normal manner using the knob (there is no time out).
3.1.3 SETTING VOLUME LEVEL
The volume level is adjusted by the top panel volume control knob or by option buttons programmed
3.2 POWER-UP PASSWORD
3.2.1 GENERAL
The power-up password feature prevents unau­thorized use of the radio by locking the keypad on power up until the proper password is entered. This feature is enabled or disabled by programming.
When it is enabled, “ENTER PSWD” is briefly displayed when power is turned on. The eight-digit
13
GENERAL OPERATION
numeric password must be then be entered as follows. If an incorrect password is entered, “INCORRECT” is displayed and it must be re-entered.
DTMF Keypad Models - Enter the password using the 1-8 keys and then press the Enter (F2) key when finished. If a mistake is made, the last digit can be erased by pressing the F1 (Clear) key.
Limited Keypad Models - Select the proper number for each position by pressing the Up/Down switch. When the proper number for a position is displayed, select it and move on to the next position by pressing the F2 (Enter) key. If the password is less than eight digits, press F2 twice after the last digit.
3.2.2 PASSWORD FEATURES
An enhanced password scheme allows up to four power-on (user) passwords, download and upload passwords, and a master password to be programmed.
The current User password can be changed if the “Set User Password” option switch or menu param­eter is programmed. Selecting this function displays prompts for entering and confirming a new password. It is recommended that a number key not be used for this function because the password mode is exited if that key is pressed to enter a number. Refer to Section 9 for more information on passwords.
3.3 ZONE AND CHANNEL SELECT
After the highest programmed zone is displayed, wrap-around to the lowest programmed zone occurs and vice versa. The selected zone is also displayed briefly on power up. If the selected zone alias needs to be displayed continuously, it must be programmed as part of the channel alias.
Channel Select
Channels are selected by the rotary 16-position switch on the top panel. The alias (identification) for the selected channel/group is displayed continuously during normal operation.
When an unprogrammed channel is selected, “UNPROGRAMD” is displayed and a tone sounds (if tones are enabled). When conventional
channels are selected and the Display Information option key or menu parameter is programmed, either the channel frequency or alias can be displayed (see Section 5.9).
The channel selector knob can also be disabled by programming. Channels must then be directly selected as described next (if applicable). It may be desirable to disable the channel select knob when direct selection is used in order to prevent confusion since the channel knob then may not indicate the selected channel.
The radio can also be programmed so that the channel select control is also be disabled by the Keypad Lock feature (Section 3.6) similar to the volume control described in Section 3.1.3.
The selected zone and channel are selected and displayed as follows. For more information on zones and channels, refer to Section 3.9.5.
Zone Select
The front panel Up/Down switch briefly displays and changes the alias of the current zone. When not in special modes such as the menu mode, pressing either the top or bottom part of this switch once displays the alias of the current zone. Then quickly pressing it again changes the selected zone up or down. The rotary A/B/C switch on the top panel can also be programmed for zone select. The “A” position then selects Zone 1, “B” Zone 2, and “C” Zone 3 (if appli­cable).
D
irect Zone/Channel Selection
The direct Channel Select feature is available if the Channel Select option switch or menu parameter is programmed. This feature allows channels to be directly selected using the DTMF keypad numeric keys (DTMF models only) or Up/Down switch (all models).
For direct selection purposes, channels are numbered sequentially starting with the lowest zone. Each zone can be programmed with up to 16 channels, so Zone 1 channels are numbered 1-16, Zone 2 chan­nels 17-32, and so on as shown below. For example, Zone 1/Channel 16 is selected by Channel 16, and Zone 2/Channel 16 is selected by Channel 32.
14
GENERAL OPERATION
Seq. Ch. No. Zone Channel
111
16 16 17 2 1
32 16 33 3 1
Proceed as follows to select channels using this
mode:
1. Enable the direct Channel Select mode by pressing the Channel Select option switch or selecting the “Chan Selct” menu parameter. The alias and sequential number of the current channel are alternately displayed.
When an unprogrammed channel is displayed, the
sequential channel number and “Unprogramd” are alternately displayed.
If an invalid channel number is entered using the
0-9 keys, or the F2 or Channel Select option switch is pressed with “Unprogrammed” displayed, an error tones sounds, “Invalid” is briefly displayed, and the displayed channel does not change.
The rotary Channel Select switch may not correctly
indicate the selected channel after direct channel selection is used. However, if this switch is enabled and rotated, it selects the channel it is indicating. For example, if the switch index is pointing to channel 3 and channel 15 of the current zone is being displayed, rotating it to channel 4 selects channel 4 of the current zone.
If the rotary Channel Select switch is enabled, the
radio always powers up on the channel it is selecting.
2. Select the desired channel using the Up/Down keys or directly enter it using the 0-9 keys (if available). If using the 0-9 keys, the radio attempts to display the entered number after the 3rd digit is entered or approximately 2 seconds after the last key is pressed.
3. T o exit the this mode and select the entered channel, press the Channel Select switch again or the F2 key . To exit without changing the channel, press the F1 key. This mode is also exited automatically without changing the channel after approximately 1 minute of no activity.
NOTE: The Channel Select function should probably not be assigned to a number key because pressing that key to select a channel then exits the select mode.
Other features of this mode are as follows:
When using the Up/Down keys, wrap-aroun d to the
lowest zone/channel occurs after the last channel in the highest programmed zone is displayed and vice versa. For example, if Zone 1/Channel 5 is the highest programmed channel, wrap-around occurs after Zone 1/Channel 16 is displayed.
If it is disabled, the radio can be programmed to power-up on the last selected or home channel number of the last selected or home zone. With the “Last Zone”/“Home Channel” configuration, the programmed home channel number of the last active zone is selected. If it is not programmed, “Unpro­grammd” is displayed. With earlier models, the last selected channel is displayed when powering up on the last selected zone, and channel 1 is displayed when powering up on the home zone.
3.4 LOW BATTERY INDICATION
3.4.1 GENERAL
NOTE: If the radio contains encryption keys and is not programmed for infinite key retention, be sure to reat­tach a battery within approximately 30 seconds to prevent the loss of these keys (see following).
A low-battery condition is indicated by the icon in the display . The battery should be recharged or replaced as soon after this indication appears. Once this indication appears, it stays on until power is cycled.
15
GENERAL OPERATION
The following additional low battery indications
and conditions may be enabled by programming:
A chirp sounds once a minute in the receive standby
and transmit modes.
A chirp sounds each time the P TT switch is pressed.
The top panel LED indicator flashes red every 30
seconds in the receive mode.
Low power is selected when transmitting.
As indicated in the preceding note, the radio may need to be connected to a constant power source to preserve the encryption keys in memory. This is required if “infinite key retention” is not To allow the battery to be changed without losing the keys with this feature disabled, storage capacitors maintain the supply voltage to memory for approxi­mately 30 seconds without a battery attached. There­fore, be sure to reattach a battery within that time. Refer to Section 8.1.6 for more information on encryption keys.
There is a battery saver feature that can be enabled by programming. This feature functions on trunked channels only, and it automatically selects low transmit power when the receive signal strength (RSSI) indicates that the site is nearby.
3.4.2 BATTERY CHARGING
NOTE: When a battery is charged while attached to the radio, make sure radio power is off (see following).
The battery can be charged separately or while attached to the radio. When it is charged while attached to the radio, radio power should be turned off. If it is not, the battery begins slowly discharging when the charger enters the trickle charge mode. This mode is indicated by a green Ready indication, and it is entered automatically when the battery is nearly fully charged. Gradual discharging occurs in the trickle mode because the charge current of approximately 50 mA is less than the radio standby current of approxi­mately 200 mA.
programmed.
UHF range). Radios programmed for SMARTNET/ SmartZone operation, for example, may affiliate while in the charger which causes them to automatically key . Therefore, do not leave radio power on while charging as described above.
3.5 BACKLIGHT
The backlight for the display and option keys can be programmed to automatically turn on when any key is pressed. It then automatically turns off after a programmed delay of 0-7.5 seconds so that battery drain is minimized. If the Backlight option switch or menu parameter is programmed, the user can manually turn the backlight on and off (it then stays on). If the Surveillance mode is programmed, the backlight is disabled (see Section 4.7). The radio can be programmed so that the backlight turns on in the keypad lock mode when a key is pressed (see next section).
3.6 KEYPAD LOCK
The Keypad Lock feature temporarily disables the front panel keys to prevent keys from being acci­dentally pressed. This feature is available if the Keypad Lock option switch is programmed. To lock the keypad, simply press the Keypad Lock option switch. Then to unlock the keypad again, press and hold this switch until a tone sounds (approximately 1 second).
Permanent Keypad Lockout can also be programmed. The keypad is then permanently disabled and cannot be enabled by the user. Additional informa­tion on this feature is as follows:
A global “Front Keypad Lockout Only” function
can be selected by programming. The front panel keys but not the side panel option keys disabled by the preceding Keypad Lock and Perma­nent Lock functions. If this function is not selected, both the front and side panel keys are disabled. The PTT switch is never disabled.
are then
CAUTION: Do not transmit in close proximity to the charger base (see following).
Do not expose the charger base to high level RF signals while a battery is being charged because this may cause a charger fuse to blow (especially in the
The Channel Selector and Volume controls can be
programmed so that they are locked by the Keypad Lock function.
The “Channel Selector Enabled” function can be
programmed globally. If this is not selected, the
16
GENERAL OPERATION
channel selector is always disabled regardless of the Permanent Lockout or Keypad Lock status. Chan­nels can then be selected only by direct channel select (see Section 3.3).
The volume control is permanently disabled if a
Volume Up/Down option switch is programmed regardless of the Permanent Lockout or Keypad Lock status. Refer to Section 3.1.3 for more information.
There is the option to enable the backlight when a
key is pressed in the Keypad Lock mode. There is also the option when programming conventional channels to disable DTMF dialing.
3.7 SETTING SQUELCH
This radio does not have a squelch control. The squelch level is preset during alignment. If the keypad programming feature is available (see Section 5.18), the squelch level can be changed by the user on each conventional analog channel.
3.8 TRANSMIT DISABLE
Transmitting can be disabled on each conven­tional, SMARTNET, SmartZone, and P25 Trunked channel so that the channel is monitor-only. When transmitting is attempted on a receive-only channel, “Rx Only” is displayed and an error tone sounds.
tional channel selects a transmit and receive frequency and other channel parameters such as squelch control coding.
Conventional channels can be either standard (analog) or Project 25 (digital). With digital operation, the DSP (Digital Signal Processor) converts the audio signal to digital data which is sent over the air as complex tones. Another difference is that analog chan­nels use Call Guard (CTCSS/DCS) squelch control and Project 25 channels use a NAC (Network Access Code) and talk group ID codes.
With Project 25 operation, a NAC is transmitted and it must match the NAC programmed in the base equipment and the radio(s) being called for communi­cation to occur. In addition, to receive standard group calls, the receiving radio must be programmed to detect the transmitted talk group ID code.
With conventional operation, a busy channel condition is detected automatically if the busy channel lockout (transmit disable on busy) feature is programmed. Otherwise, it must be detected manually . An out-of-range condition is not indicated by special tones or messages as with SMARTNET operation because there is no initial data exchange with the repeater that allows this condition to be detected. Operating features unique to conventional channels are described in Section 5.
3.9 RADIO OPERATING MODES
3.9.1 GENERAL
Each selectable channel can be programmed for the conventional (analog or APCO Project 25 digital), SMARTNET/SmartZone, or APCO Project 25 digital trunked operating mode. For example, Zone 1/Channel 1 could be a conventional channel, Zone 1/Channel 2 a SMARTNET channel, and so on. More information on these modes follows.
3.9.2 CONVENTIONAL MODE
This is a non-trunked operating mode which accesses independent radio channels. There is no auto­matic access to several channels. Selecting a conven-
3.9.3 SMARTNET/SMARTZONE MODE
This is a trunked operating mode in which auto­matic access is provided to several RF channels. ID codes are used to select what radios are being called and what calls are received. Monitoring is performed automatically and special messages and tones indicate busy and out-of-range conditions.
SMARTNET and SmartZone operation and programming is very similar. Basically, SMARTNET operation is limited to a single repeater site and Smart­Zone operation allows automatic roaming between sites. Enhanced SMARTNET/SmartZone features include roaming (SmartZone only), telephone, private, and emergency calls, Call Alert
, and messaging. Either analog or digital signaling may be used (digital is optional).
17
GENERAL OPERATION
When a SMARTNET or SmartZone channel is selected or the radio is powered up on one of those channels, it searches for a control channel. Once a control channel is found, the alias (name) of the selected channel is displayed and the radio attempts to register on the radio system. If a control channel could not be found (because of an out of range condition or the system ID is not correct, for example), “NO SYS” (early units) or “Out Rnge” (later units) is displayed and the radio continues to search for a control channel.
The control channel transmits and receives system information to and from all radios registered on the system. Therefore, once a control channel is found, it is continuously monitored for incoming call infor­mation and is used to make call requests. The radio automatically changes to a traffic channel to place and receive calls and then returns to the control channel when the call is complete. Operating features unique to SMARTNET/SmartZone channels are described in Section 6.
3.9.4 P25 TRUNKED MODE
The P25 Trunked operating features are very similar to the SmartZone type just described. Since SmartZone features are also similar to SMARTNET features, all three modes are described in the Section 6. Some differences between the P25 Trunking and SmartZone modes are as follows:
Digital signaling is always used with P25 calls.
Either analog or digital signaling may be used for SmartZone calls.
Calls made to a specific radio in the P25 mode are
called Unit Calls. In the SMARTNET/SmartZone mode they are called Private Calls.
Messaging is not available with P25 calls.
Subsystem ID (RFSS). The SmartZone mode does not use the WACN and RFSS IDs.
P25 Unit IDs can be 1-16,777,215 (000001-FFFFFF
hex) and SmartZone Unit IDs can be 1-65,535 (0001-FFFF hex).
3.9.5 SYSTEMS, CHANNELS, AND ZONES
A zone and channel are selected to place and receive calls. The following describes the relationship between systems, channels, and zones.
Systems
A system is a collection of channels or talk groups belonging to the same repeater site. It defines all the parameters and protocol information required to access a site. Up to 16 systems of any type can be programmed.
The maximum number of channels assignable to a system is limited to 512. Channels may also be limited by available memory space as described in the following information.
Channels
A channel selects a radio (RF) channel or talk group as follows:
Conventional Analog Mode - A channel selects a specific radio channel, Call Guard (CTCSS/DCS) squelch coding, and other parameters unique to that channel.
Conventional Project 25 Mode - A channel selects a specific radio channel, NAC squelch coding, talk group ID, and other parameters unique to that channel.
The P25 control channel data rate is 9600 baud and
the digital voice data rate is also 9600 baud. With SmartZone operation, the control channel data rate is 3600 baud (both digital and analog calls) and the narrowband digital voice data rate is 9600 baud.
The P25 mode uses a system ID, Wide Area
Communications Network (WACN) ID, and RF
SMARTNET/SmartZone and Trunked Project 25 Modes - A channel selects a specific talk group,
announcement group, emergency group, and other parameters unique to that talk group.
A maximum of up to 512 channels can be programmed with the preceding modes. These chan­nels can belong to a single system or multiple systems.
18
GENERAL OPERATION
The maximum number is also limited by the available memory. For example, since more memory is required to program a SMARTNET system than a conventional system, the total number of channels decreases as the number of SMARTNET channels increases. The programming software displays a bar graph which shows the amount of available memory space that is used by the current data.
Zones
A zone is a collection of up to 16 channels of any type. For example, a zone could include 12 conven­tional channels and 4 SMARTNET channels. One use of zones may be to program the channels used for operation in a different geographical areas. The maximum number of zones is 32.
19
SECTION 4 RADIO-WIDE FEATURES
4.1 OPTION SWITCHES
NOTE: For descriptions of the functions controlled by these switches, refer to the section of this manual referenced in the last column of Table 4-1.
Almost all the buttons on this radio are
programmable as follows:
On the side panel, the three buttons above the PTT
switch (see Figure 2-3 on page 11).
RADIO-WIDE FEATURES
On the top panel, the rotary three-position switch
and the orange button (see Figure 2-2 on page 11).
On the front panel, F1 and F2 unless the menu mode
is used (see next section), and F3 and F4.
With DTMF keypad models, all 12 DTMF keys.
The functions that can be controlled by option switches are shown in Table 4-1. Each option switch can be programmed to control a different function in each of the three operating modes. For example, F3 can control one function when a conventional channel is selected, another when a SMARTNET/SmartZone channel is selected, and still another when a Project 25 trunked channel is selected.
4.2 MENU MODE
NOTE: For descriptions of the functions controlled by the menu mode parameters, refer to the section of this manual referenced in the last column of Table 4-1.
Most functions that can be controlled by an option switch can also be controlled by the menu mode. The functions that can be controlled by the menu mode are shown in Table 4-1. Functions can be controlled by both an option switch and a menu parameter if desired.
When the menu mode is used, the F1 and F2 switches become dedicated menu mode control switches (see following illustration). The F1 switch is Back/Clear, and the F2 switch is Menu Select/Enter. If the menu mode is disabled, these switches can be programmed for other functions.
Menu Mode Buttons
Only the enabled menu items which apply to the selected channel type are displayed. For example, if a conventional channel is selected, only the enabled functions for conventional channels are displayed.
When in the menu mode, messages continue to be received on the selected channel. However, the display does not indicate who is calling. Pressing the PTT switch exits the menu mode and keys the transmitter.
The menu mode operates as follows:
1. To select the menu mode, press the F2 key. Up to
three menu parameters are then displayed as shown in the preceding illustration.
2. To scroll up or down through the menu parameter
list, press the Up/Down switch. The selected parameter is indicated by a dark bar.
3. To display the available modes for a highlighted
parameter, press the F2 switch. The currently selected mode is indicated by an asterisk.
4. Press the Up/Down switch to highlight the desired
mode. Then press the F2 key to select that mode.
5. To step back to the previous level or exit the menu
mode, press the F1 (Back) key.
4.3 TIME-OUT TIMER
The time-out timer disables the transmitter if it is keyed continuously for longer than the programmed
20
RADIO-WIDE FEATURES
Table 4-1 Programmable Option Switch and Menu Mode Functions
Function
Alert tones On-Off TonesXXXX4.6 Backlight On-Off BacklightXXXX3.5 Call Alert Select Call AlertXXXX5.17.7, 6.7 Call Response Select Call Rsp X X X 6.5 Cancel Dynamic Regroup Cancel DR X X X 6.13 Change Keyset (OTAR)Chg KeysetXXXX10.6.3 Channel Select Chan SelctXXXX3.3 Clear/Secure Select SecurityXXXX10.3 Clone Select (menu only) Clone X 5.16 Configure (menu only)ConfigXXXXNot curr. used Digital Talk Group Select Select TG X 5.17 Display Information Select Display X 5.9 Emergency Select EmergencyXXXX Erase Keys (menu only)Erase KeysXXXX10.2.6 High/Low Power SelectTx PowerXXXX4.5 Home Zone SelectHome ZoneXXXX4.4 Key Select Key Select X 10.2.5 Keypad Lock Select (Opt sw only) X X X X 3.6 Keypad Programming Select Keypad Prg X 5.18 Messaging Message X X X 5.17.8, 6.8 Monitor Mode Select Monitor X 5.3 Normal/Selective Select Squelch X 5.5 OTAR Rekey Request OTAR Rekey X 10.6.3 P25 Packet Data Data Modes X X 5.17.10 Phone Call Select PhoneXXXX5.17.6, 6.6 Priority Channel Select Priority X 5.11.3 Private Call Select Priv Call X X 6.5 Radio Wide Scan SelectRW ScanXXXX4.8 Repeater Talk-Around Select Talk Arnd X 5.8 RWS List Edit RWS EditXXXX4.9.2 Scan Mode Select ScanXXXX4.8 Scan List Edit SelectScan EditXXXX4.8 Scan List Select Scan SelctXXXX4.8 Set User Password Set PaswdXXXX9 Squelch Select List Sqlch Code X 5.5 Single Tone Encoder Tone Encdr X 5.14 Site Lock Select Site Lock X X 6.14 Site Search Select Site Srch X X 6.14 Status Select StatusXXXX5.17.9, 6.9 Surveillance Mode SelectSurv ModeXXXX4.7 Tone Volume Edit Tone VolXXXX4.6 Unit Call Select Unit Call X X 5.17 Unprogrammed (not used)-XXXX ­Volume Down (Opt sw only)XXXX3.1.3 Volume Up (Opt sw only)XXXX3.1.3
Menu
Display
Conv. P25 Trk SMARTNET SmartZone
Available in Mode:
See Descript.
in Section:
5.10, 6.10
21
RADIO-WIDE FEATURES
time. It can be programmed for 15 seconds to 3 minutes, 45 seconds or it can be disabled.
If the transmitter is keyed for longer than the programmed time, the transmitter is disabled, a contin­uous tone sounds, and “TX TIMEOUT” is displayed. Five seconds before time-out occurs, a warning beep sounds to indicate that time-out is approaching. The timer and tone are reset by releasing the PTT switch.
A different time can be programmed for each system, and the timer can be enabled or disabled on each conventional channel. With conventional chan­nels, a penalty time may also be programmed that prevents transmissions for a certain time after the transmitter is disabled (see Section 5.6).
One use of this feature is to prevent a channel from being kept busy for an extended period by an accidentally keyed transmitter. It can also prevent possible transmitter damage caused by transmitting for an excessively long period.
4.4 HOME ZONE/CHANNEL SELECT
The new level is flashed in the display as either “HI POWER” or “LOW POWER”. If selectable power is not permitted on the current channel, “FIXED LOW” or “FIXED HIGH” is flashed and no change occurs. The selected power level for a channel or system is permanent until it is manually changed again. The low power mode may be automatically selected during a low battery condition (see Section 3.4).
4.6 ALERT TONE SELECT
The various alert tones that sound are described in Section 7.1. These tones can be turned on and off if the Alert T one option switch or Tones menu parameter is programmed. When all tones are off, “TONE OFF” is momentarily displayed, and when all tones are on, “TONE ON” is momentarily displayed. If this switch or menu parameter is not programmed, tones are fixed in the on or off mode by programming. If the Surveil­lance mode is programmed (see following), tones are totally disabled.
If the Home Zone option switch or menu param­eter is programmed, it selects the preprogrammed home zone. The selected channel is displayed if the channel switch is enabled, and the preprogrammed home channel is selected if it is disabled.
Pressing and holding the Home Zone option switch until a tone sounds makes the currently selected zone the new Home zone. The radio is also programmed so that either the home or last selected zone is selected when power is turned on. Refer to Section 3.3 for more information.
4.5 POWER OUTPUT SELECT
Each conventional channel and SMARTNET/ SmartZone and P25 Trunked system can be programmed for high, low, or switchable power. If the High/Low Power option switch or menu parameter is programmed and selectable power is programmed on the current channel or system, high and low trans­mitter power can be selected. All models support high and low power. The low power level is typically 1 watt and the high power level the rated power output of the radio (2.5 - 5 watts, depending on frequency band).
The Alert Tone volume can be adjusted relative to the volume control setting. This is done by program­ming and also by the user if the Tone Volume Adjust option button or menu parameter is programmed. Relative levels of –170 to +170 can be set with “0” the default setting. A minus value decreases the tone volume and a plus value increases it. The user adjusted level permanently overrides the programmed level if applicable.
4.7 SURVEILLANCE MODE
The Surveillance mode totally disables the back­light, all alert tones, and front panel LED indicator in all operating modes. The radio can be fixed in this mode by programming or it can be turned on and off by the user if the Surveillance Mode option button or menu parameter is programmed. The user selected mode permanently overrides the programmed mode if applicable. To provide a transmit indication when the front panel LED is disabled, the icon is displayed (see Section 2.4). This icon is displayed only in the surveillance mode.
22
RADIO-WIDE FEATURES
4.8 SCANNING
4.8.1 INTRODUCTION
Scanning monitors the channels in the scan list for messages that the radio is programmed to receive. When a message is detected, scanning stops and the message is received. Shortly after the message is complete, scanning resumes (unless it has been disabled). When a call is received in the scan mode, the alias of the channel on which a call is received (and any other display parameters that may be programmed) are displayed until scanning resumes. The selected channel alias is then displayed if applicable.
There are two basic scan modes available: Priority (Standard) and Radio Wide. The operation of the priority type is unique to the type of channel selected, and the operation of Radio Wide type is the same regardless of the type of channel selected. Only one type can be enabled at a time. For example, if priority scanning is enabled and radio wide scanning is selected, priority scanning is automatically disabled and vice versa. More information on these types of scanning follows.
4.8.2 PRIORITY SCANNING
Priority scanning (also referred to as standard scan) monitors only channels that are the same type as that currently selected. For example, if a conventional channel is selected, only conventional channels are scanned and likewise for SMAR TNET/SmartZone and Project 25 Trunked channels.
More information on how priority scanning oper­ates in the Conventional Mode is located in Section
5.11, and for the other modes in Section 6.12. Priority scanning is turned on and off by the Scan option switch or menu parameter as follows. If this switch or menu parameter is not programmed, Priority scanning is not available.
disabled when “Scan Off” is briefly displayed and the icon is no longer indicated.
If the zone or channel is changed while scanning is
selected, scanning continues on the same or a different scan list (see Section 4.9.1).
NOTE: Each SMARTNET/SmartZone and P25 trunked channel can be programmed so that scanning is auto­matically enabled when the channel is selected.
4.8.3 RADIO WIDE SCANNING
NOTE: Use radio wide scanning only if two different channel types need to be scanned at the same time such as conventional and SMARTNET/SmartZone. Otherwise, use the more efficient priority scanning because there is less chance of missed calls.
Radio wide scanning monitors the channels in the preprogrammed radio-wide scan list. This scan list can include up to 16 channels of any type and assigned to any zone (see Section 4.9.2). Radio wide scanning is turned on and off by the Radio Wide Scan option switch or menu parameter as follows. If this switch or menu parameter is not programmed, ra dio wide scan­ning is not available.
Enable Radio W ide Scanning using the Radio W ide
Scan option switch or menu parameter. Radio wide scanning is enabled when “RW Scn On” is briefly displayed and the icon is indicated.
To turn radio wide scanning off, press the Radio
Wide Scan option switch again or select “Off” in the menu. Scanning is disabled when “RW Scn Off” is briefly displayed and the icon is no longer indicated.
If the zone or channel is changed while radio wide
scanning, scanning continues normally.
4.8.4 SCAN HOLD TIME
Enable scanning using the Scan option switch or
menu parameter . Scanni ng is en abled when “Scan On” is briefly displayed and the icon is indicated.
To turn scanning off, press the Scan option switch
again or select “Off” in the scan menu. Scanning is
When a message is received or transmitted while scanning, there is a delay before scanning resumes. The delay after receiving a call prevents another message from being received before a response can be made. The delay after transmitting a call ensures that a response is heard instead of another message occurring on some other channel.
23
RADIO-WIDE FEATURES
Separate delay times are programmable for Radio Wide and Priority scanning. With radio wide and conventional priority scanning, delays of 0-7.5 seconds are programmable in 0.5-second steps. With SMARTNET/SmartZone and P25 Trunked priority scanning, a scan delay of 2-10 seconds can be programmed in 0.5-second steps.
4.8.5 TRANSMITTING IN THE SCAN MODE
Priority S
enabled, the transmission may occur on various channels as follows.
Radio Wide Scan Mode
selected or active channel similar to SMARTNET/ SmartZone and P25 trunked operation just described.
can Mode
When the transmitter is keyed while scanning is
Conventional Operation - Transmissions can be programmed to always occur on the priority, selected, or receive channel (if applicable). Refer to Section 5.11 for more information.
SMARTNET/SmartZone/P25 Trunked Operation - If scanning is halted to receive a
message, programming determines if transmis­sions occur on the selected or active channel. Transmissions at other times occur on the selected channel.
The radio can be programmed to transmit on the
2. The channel is then deleted and scanning of the remaining channels in the scan list resumes.
3. Deleted channels are added back into the scan list if any of the following occur:
Scanning is turned off and then on again using the
Scan option switch or menu parameter.
Radio power is turned off and then on again.
The selected channel is changed.
4.9 SCAN LISTS
4.9.1 PRIORITY SCAN LISTS
General
NOTE: The selected channel is always scanned.
A scan list is simply the channels that are scanned when scanning is enabled. With all operating modes, as many priority scan lists as are required can usually be programmed (up to 256). The only limitation is the available memory . Each scan list can include up to 512 channels/talk groups. More information on selecting and editing priority scan lists follows.
D
etermining Channels in Priority Scan List
4.8.6 NUISANCE CHANNEL ADD/DELETE
With priority scanning, channels can be tempo­rarily deleted from the scan list, for example, if messages become annoying. This feature is not avail­able with radio wide scanning. Channels can also be permanently added or deleted from a scan list as described in the next sections. Proceed as follows to temporarily delete a nuisance channel:
NOTE: The selected channel and also priority chan­nels cannot be deleted from the scan list.
1. While receiving a message on the channel to be
deleted, press and hold the Scan option switch until a tone sounds (about 1 second).
The channels in conventional priority scan lists are indicated by selecting the scan mode as follows. Channels in SMARTNET/SmartZone/P25 Trunked priority scan lists are indicated only when editing a scan list (see “Editing a Priority Scan List” which follows).
1. Enable priority scanning using the Scan switch or
menu parameter. Also select the scan list if appli­cable as described in the following “Selecting a Priority Scan List” description.
2. Select the desired zone and then scroll through the
channels by rotating the channel switch. When the displayed channel is in the scan list (scanned normally), the icon is displayed.
24
RADIO-WIDE FEATURES
Selecting a Priority Scan List
NOTE: Only priority scan lists are selectable.
Conventional Channels - Conventional systems are programmed with a default scan list that is normally selected by all channels in th at system . However, there is a programmable option to slave a particular conven­tional scan list to a zone. This then becomes the default list for all conventional channels in that zone (it overrides the system programming). This slave feature is programmed on the Edit Zone screen.
If the Scan (List) Select option switch or menu param­eter is programmed, the default list selected by all conventional channels (even those belonging to slaved zones) is temporarily changed. The preceding default scan lists are automatically reselected whenever radio power is cycled.
SMARTNET/SmartZone and Project 25 Trunked Channels - Each channel (talk group) can be
programmed so that one of the programmed lists is selected or scanning is disabled (No List). In addition, channels can be programmed so that scanning is auto­matically enabled (Auto Scan) when they are selected.
If the Scan (List) Select option switch or menu param­eter is programmed, the list that is selected by all talk and announcement groups in the current system can be temporarily changed by the user as follows. “No List” (scanning disabled) or “Programmed” (default list) can also be selected if desired. The programmed default scan list is automatically reselected on power up.
To change the currently selected scan list (all
channel types), proceed as follows:
1. With scanning disabled ( icon not displayed), press the Scan List option switch or select the Scan Selct menu parameter.
2. The currently selected list is displayed as “List x”, where “x” is the currently selected list. To exit without changing the selected list, simply press the Scan List option switch again or the F1 key.
3. To select another list, press the Up/Down switch. When the desired list is displayed, select it and exit
this mode by pressing the Scan List option switch again or the F1 or F2 key.
Editing a Priority Scan List
If the Scan Edit option switch or menu parameter is programmed, conventional, SMARTNET/ SmartZone, and P25 Trunked priority (standard) scan lists can be user programmed. Changes are permanent (cycling power does not reselect a default condition). Proceed as follows:
1. Make sure that both priority and radio wide scan-
ning are off ( icon not displayed). Select a conventional or SMARTNET/SmartZone/P25 Trunked channel corresponding to the scan list being programmed.
2. Select the scan edit mode using the Scan Edit option
switch or menu parameter. This mode is indicated by in the d isplay.
3. If applicable, select the list to be edited by pressing
the Up/Down switch. Select the desired list by pressing the F2 key . The selected list is indicated as “LIST x”. If user programming is disabled on a list, (conventional only) “NO EDIT” is momentarily displayed and it cannot be edited.
4. Select the channel you want to add or delete by
pressing the Up/Down switch. After the last channel in the current zone is displayed, the first valid channel in the next zone is displayed and vice versa. Lists are limited to 512. If an attempt is made to add more than 512, “LIST FULL” is displayed and a channel must be deleted before another can be added.
NOTE: Priority channels can be deleted.
5. If the selected channel is in the scan list (scanned),
the icon is displayed. To change the status of the displayed channel, press the F2 (Enter) switch.
With conventional channels only, if the selected scan list is programmed with fixed
priority channel(s), the next press of F2 makes the current channel the priority channel indicated by . If dual priority channels are used, pressing F2 again makes it the second priority channel indicated by
25
RADIO-WIDE FEATURES
. Then pressing F2 again takes the channel out
2
of the scan list. Refer to Sections 5.11.3 and 6.12.2 for more information on priority channel sampling.
6. T o exit this mode and save the changes, press the F1 (Exit) key or the Scan Edit option switch again.
7.
4.9.2 RADIO WIDE SCAN LISTS
General
With radio wide scanning, there is only one scan list available regardless of the type of channel selected. This list is user programmable in later units, and can contain up to 16 channels of any type. For example, it could include six conventional channels and ten SMARTNET/SmartZone channels. More information on selecting and editing radio wide scan lists follows.
Determining
Channels in Radio Wide Scan List
E
diting a Radio Wide Scan List
If the RWS Edit option switch or menu param­eter is programmed, the radio wide scan list can be edited. Changes are permanent (cycling power does not reselect a default condition). Proceed as follows:
1. Make sure that both priority and radio wide scan-
ning are off ( icon not displayed). Select the scan edit mode using the RW S Edit option switch or menu parameter. This mode is indicated by in the display.
2. Select the channel you want to add or delete by
pressing the Up/Down switch. After the last channel in the current zone is displayed, the first valid channel in the next zone is displayed and vice versa. Lists are limited to 16 channels. If an attempt is made to add more than 16, “LIST FULL” is displayed and a channel must be deleted before another can be added.
The channels in radio wide scan lists are deter­mined by selecting the scan list edit mode (see “Editing Radio Wide Scan List” which follows).
When the displayed channel is in the radio wide scan list (scanned normally), the icon is displayed.
3. If the selected channel is in the scan list (scanned),
the icon is displayed. To change the status of the displayed channel, press the F2 (Enter) switch.
4. T o exit this mode and save the changes, press the F1 (Exit) key or the RWS Edit option switch again.
26
CONVENTIONAL MODE FEATURES
SECTION 5 CONVENTIONAL MODE FEATURES
5.1 INTRODUCTION
An overview of the conventional operating mode is located in Section 3.9.2. The following information describes the features unique to analog and digital (Project 25) conventional operation. Refer to the preceding “Radio Wide Features” section (4) for infor­mation on features common to all operating modes.
5.2 MONITORING BEFORE TRANSMITTING
With conventional operation, you may need to manually monitor the channel before transmitting to make sure that it is not be used by someone else. If you were to transmit while someone else was using the channel, you would probably disrupt their conversa­tion. With SMARTNET/SmartZone and P25 Trunked operation, monitoring is performed automatically. Monitor conventional channels automatically or manually as follows:
Automatic Channel Monitoring
If the selected channel is programmed for Busy Channel Lockout (also called Transmit Disable On Busy), monitoring is performed automatically. Refer to Section 5.4 for more information on this feature.
Manual Channel Monitoring
The automatic monitoring just described may occasionally disable the transmitter when the channel is not in use, such as if the repeater has extended hang time. In this case, you may not want to use it and the channel must then be monitored manually as follows:
Busy Indicator - With scanning disabled, note if the multi-function indicator on the front panel is steady green. If it is not, the channel is not being used and a call can be transmitted. It it is green, a carrier is being detected, so the channel may be busy (see following).
Monitor Mode - There may be times when a busy condition is indicated even though no one is using the channel. Monitoring should then be performed by disabling Call Guard squelch (or group ID detect on Project 25 channels). This is usually done by selecting
the Monitor Mode (see following) or by the Normal/ Selective option switch or menu parameter (see Section
5.5.5).
5.3 MONITOR MODE
The monitor mode unsquelches the receiver and monitors the channel even if a carrier is not detected. Other features of this mode are as follows:
Call Guard (CTCSS/DCS) squelch is disabled on
analog channels and NAC and group ID detect are disabled on P25 (conventional) channels.
Busy Channel Lockout is overridden (see next
section)
Scanning temporarily halts
The Monitor Mode operates as follows:
1. To monitor the transmit
before transmitting, briefly press the Monitor option switch or select the Monitor menu “Tx Channel” parameter. The icon is then displayed to indicate the monitor mode and the receiver unsquelches.
2. T o monitor the receive
hold the Monitor option switch until a tone sounds or approximately 2 seconds, or select the Monitor menu “Sqlch Ovrd” parameter. This can be used, for example, to improve reception if intermittent squelching is making a weak message difficult to understand.
3. To disable the monitor mode and return to normal
operation, press the Monitor option switch again of select the Monitor menu “Off” parameter.
The Normal/Selective function disables Call Guard squelch and P25 group ID detect but not scanning and P25 NAC detect (see Section 5.5.5).
5.4 BUSY CHANNEL LOCKOUT
The Busy Channel Lockout feature (also called Transmit Disable on Busy) automatically disables the transmitter if the channel is busy when the PTT switch is pressed. When the transmitter is disabled by this
frequency for activity
frequency instead, press and
27
CONVENTIONAL MODE FEATURES
feature, “BUSY” is displayed, a busy tone sounds, and the transmitter is disabled.
The Busy Channel Lockout feature can be programmed to operate as follows. Each conventional channel can be programmed differently.
Off - Busy channel lockout is disabled and the trans­mitter keys even if the channel is busy.
Noise - If a carrier is detected on the channel, the transmitter is disabled when the PTT switch is pressed.
To ne (NAC) - If an incorrect Call Guard (CTCSS/ DCS) or NAC code (see Section 5.17) is detected, the transmitter is disabled when the PTT switch is pressed. An incorrect code is any code other than the one programmed for the current channel.
If Busy Channel Override is permitted by programming, it is possible to transmit even when the transmitter is disabled by this feature. Simply release the PTT switch and then quickly press it again.
5.5 CALL GUARD SQUELCH
5.5.1 INTRODUCTION
Tone or digital Call Guard squelch (also called CTCSS/DCS signaling) can be programmed on each conventional analog transmit and receive channel in any order desired. The reverse burst and turn-off code are always transmitted and also detected on channels programmed with Call Guard squelch.
receive Call Guard squelch on analog channels or group ID code detection on P25 channels. When selec­tive squelch is disabled, “Sq Normal” is flashed in the display, and when it is enabled, “Sq Select” is flashed.
When “Normal” is selected, the receiver unsquelches only if a carrier is detected. Scanning and Project 25 NAC detection are not disabled with this mode selected. The selected mode is in effect until it is manually changed again. Selecting another channel or cycling power does not reselect a default condition. There is a programmable option to display the monitor
icon when the “Normal” mode is selected.
5.5.3 TONE CALL GUARD SQUELCH
Tone-type Call Guard squelch utilizes subaudible CTCSS tones from 67-254.1 Hz. Although there are 42 tones assigned, those above 33 (210.7 Hz) are normally not used because of their close proximity to the voice band which starts at 300 Hz. In addition, tones 11 (97.4 Hz), 39 (69.3 Hz), 40 (206.5 Hz), 41 229.1 Hz), and 42 (254.1 Hz) are normally not used because they may cause interference with adjacent tones.
A reverse burst is transmitted when the push-to­talk switch is released and also detected when calls are received. It is a 180-degree phase reversal for a period of time determined by the tone frequency, and it elimi­nates the squelch tail (noise burst) in the receiving radio. Both the transmitting and receiving radio must be equipped with this feature for it to be utilized.
5.5.4 DIGITAL CALL GUARD SQUELCH
The Call Guard squelch feature eliminates distracting messages intended for others using the channel. This is done by using a subaudible tone or digital code to control the squelch. This tone or code is unique to a user or a group on that channel. This tone or code is transmitted with the voice signal but is not heard because it is in the subaudible range and is atten­uated by a filter. Call Guard squelch must be used in both the transmitting and receiving radio to be func­tional.
5.5.2 CALL GUARD SQUELCH ENABLE/
DISABLE
The Normal/Selective option switch or menu parameter (if programmed) can be used to disable
Digital Call Guard squelch (DCS) uses digital data instead of subaudible tones to control the squelch. This data consists of continuous repetitions of 23-bit words. No bit or word synchronization information is used. When the push-to-talk switch is released, a turn­off code is transmitted which eliminates the squelch tail similar to the reverse burst.
Although there are thousands of possible code combinations with 23 bits, only 83 are unique with the data scheme used. The number specified when the code is programmed is actually a seed for a special algorithm used to generate the 23-bit data word. The data is transmitted at a rate of 134.4 bits per second. Therefore, approximately six words are transmitted each second. When the data is decoded, 23-bit samples
28
CONVENTIONAL MODE FEATURES
are taken and then the bits are rotated to determine if a valid code was received.
5.5.5 SELECTIVE SQUELCH CODE SELECT (CTCSS/DCS/NAC)
NOTE: Call Guard codes can be permanently repro­grammed by keypad programming described in Section 5.18.
This feature allows the normal transmit and receive Call Guard (CTCSS/DCS/NAC) program­ming to be temporarily overridden with a code selected from a preprogrammed list. It is available if the Squelch Select List option switch or menu param­eter and a CTCSS/NAC code list have been programmed.
In addition, conventional systems can be programmed for the Keypad CTCSS/DSC feature. Codes can then be selected directly from the table by pressing the key for the code. For example, to select code 3 from the table, simply press the “3” key. No other conventional mode functions can then be assigned to these keys.
The CTCSS/DCS/NAC list is programmed with up to 64 tone (CTCSS) or digital (DCS) Call Guard codes. Different codes can be programmed for the transmit and receive modes, and carrier squelch (selec­tive squelch disabled) can be programmed if desired. In addition, each position can be programmed with an NAC code for use with P25 operation.
When the Call Guard code is changed using this feature, it remains selected even if other channels are selected. However, if radio power is cycled or a talk­around channel is selected, the normal codes are rese­lected. When scanning, the selected code also applies to all scanned channels. Each channel can also be programmed to always ignore the code selected from this list and use the default code instead.
programmed for the transmit mode determines the selective squelch type used.
Proceed as follows to select a code using the
Squelch Select List option button or menu parameter:
1. Press the Squelch Select List option switch or select the Sqlch Code menu mode parameter. Then press the Up/Down switch to select the desired code. The display indicates “SEL SQ xx” where, “xx” is the selected code from 1-64. The code number and actual code are alternately displayed (NACs are displayed in hexadecimal).
2. T o select the displayed code and return to the normal display, press the F2 (Select) key or the Squelch Select List switch again.
3. To check which code is selected, press the Squelch Select List switch once to display the current selec­tion and then again to return to normal operation.
4. To return to the normal selective squelch codes, select “DEFAULT” in this mode. As previously described, the normal codes are also automatically reselected whenever radio power is cycled or a talk­around channel is selected.
5.6 PENALTY TIMER
A penalty timer may be programmed on conven­tional systems to prevent transmissions for the programmed time after the time-out timer disables the transmitter (see Section 4.3). The penalty timer can be programmed for the same times as the time-out timer, and timing starts when the PTT switch is released. If the PTT switch is pressed during the penalty time, the time-out indication occurs again and the transmitter remains disabled. When the penalty timer expires, a beep sounds and the transmitter can be keyed.
5.7 CONVERSATION TIMER
If both analog and digital (Project 25) channels can be selected or scanned, the CTCSS/DCS code for the selected position is used for analog channels and the NAC code for the selected position is used for P25 channels. If a channel is programmed for mixed mode operation, the selective squelch type (analog or digital)
A conversation timer can be programmed on conventional systems in addition to the time-out timer (see Section 4.3). This timer limits the total length of a conversation rather than just the length of each trans­mission as with the time-out timer. The following is more information on this timer.
29
CONVENTIONAL MODE FEATURES
It can be programmed for times up to 7.5 minutes.
It is reset when the time between transmissions
exceeds the time programmed for the penalty timer.
A warning beep sounds 5 seconds before this timer
disables the transmitter.
When this timer disables the transmitter, a contin-
uous tone sounds and the red transmit indicator turns off. The PTT switch must then be released until the penalty timer expires (indicated by a beep).
5.8 REPEATER TALK-AROUND
Normally, all transmissions go through a repeater which usually increases range. However, there may be times when a user is out of range of the repeater and therefore unable to talk to anyone even though the user being called is only a short distance away. To allow communication in this situation, repeater talk-around can be selected. Transmissions then occur on the receive frequency which permits direct radio-to-radio communication.
Repeater talk-around can be selected if the RTA option switch or menu parameter is programmed. When talk-around is enabled by this switch, is displayed. This feature remains enabled during scan­ning, and changing channels or turning power of f does not change the selected condition. Talk-around is available on conventional channels only, and power output is reduced in this mode.
5.9 DISPLAYING TRANSMIT/RECEIVE
FREQUENCY
If the Displayed Information option switch or menu parameter is programmed (see Section 4.1), it can be used to display the channel frequency in megahertz. Pressing this switch toggles between displaying the standard channel alias and the channel frequency. The receive frequency is displayed when receiving and the transmit frequency is displayed when transmitting. This feature is available on conventional channels only.
5.10 EMERGENCY ALARM AND CALL
5.10.1 INTRODUCTION
gency option switch or menu parameter is required for these functions. Emergency Alarms and Calls are transmitted on the global (radio wide) emergency zone/channel if one is programmed. If it is not programmed, the emergency is transmitted on the selected channel. The emergency programming of the system to which that channel is linked controls the emergency operation.
5.10.2 EMERGENCY ALARMS
An emergency alarm is a special transmission that alerts a dispatcher of an emergency situation. It is sent automatically by simply pressing the Emergency option switch or selecting the Emergency menu parameter. The system to which the emergency channel is linked must have Emergency Alarms enabled. If it does not, Emergency Alarms are disabled.
In the P25 conventional mode, a special P25 emergency data transmission is sent, and in the conventional analog mode, an DTMF emergency ID is sent. This ID is programmed on the Conventional Radio Wide screen. Refer to Section 5.15 for informa­tion on MDC1200 Emergency Alert.
Proceed as follows to send an emergency alarm:
1. If required, select a channel of a system on which
Emergency Alarms are enabled and then press the Emergency option switch or select that menu parameter. The radio then automatically transmits the emergency alarm.
2. Either Normal or Silent operation can be
programmed. With Normal operation, the red LED lights, the emergency tone sounds, and “EMERGNCY” flashes in the display. This indica­tion continues to flash until the alarm mode is ended (see step 4). If silent operation is programmed or the Surveillance mode is selected (see Section 4.7), none of these indications occur. If “No Receive Activity During Emergency” is programmed, receive audio, the front panel LED, and receive icons are disabled in the receive mode.
Emergency Alarms and Calls are separate func­tions that can be individually enabled or disabled on each analog and P25 conventional system. The Emer-
3. When the emergency alarm is acknowledged by the dispatcher, “ACK RCVD” is briefly displayed and the emergency acknowledge tone (two beeps)
30
CONVENTIONAL MODE FEATURES
sounds. This alert tone can be disabled if desired, and neither occur if Silent operation is programmed.
4. The emergency alarm mode is exited when radio power is cycled or by pressing and holding the Emergency option switch.
5.10.3 EMERGENCY CALLS
General
The Emergency Call feature allows a user to place an emergency voice call by pressing the PTT switch after pressing the Emergency option button or selecting the Emergency menu parameter. If the Emer­gency Hot Mic feature is enabled, the emergency call is automatically transmitted without having to press the PTT switch (see following description). The system to which the emergency channel is linked must have Emergency Calls enabled. Analog and Digital (P25) calls can be individually enabled.
If the emergency call is sent on a P25 channel, an emergency indication is sent according to the P25 standard (the emergency bit is set in the Common Air Interface). If it is sent on an analog channel, the DTMF Emergency ID is sent in place of the ANI DTMF PTT ID if applicable. NOTE: The DTMF
Emergency ID is sent only if pre- or post- DTMF ANI is enabled on the channel by programming.
Emergency Hot Mic
If Emergency Hot Mic has been enabled for emergency calls, automatic transmitting occurs with microphone audio unmuted without having to manu­ally press the PTT switch. The automatic tran s mit period is programmed for 10-120 seconds in 10­second steps. If this feature or emergency calls are not enabled by programming, automatic transmitting does not occur. This feature is initiated only on the first press of the Emergency switch. Subsequent presses do not trigger automatic transmissions. To reset this func­tion, the channel must be changed or power cycled.
Placing an Emergency Call
1. If required, select a channel of a system on which
Emergency Calls are enabled and press the Emer­gency option switch or select that menu parameter.
The Emergency Alarm is then sent as described in Section 5.10.2 if applicable.
2. If the preceding Emergency Hot Mic feature is enabled, the call is automatically transmitted without pressing the PTT switch. If it is disabled, press the PTT switch and begin speaking as with a standard call. If the channel is changed, operation continues on the new channel in the emergency mode.
3. With analog calls, subsequent presses of the PTT switch cause the DTMF emergency ID to be sent according to the ANI programming (if DTMF ANI is enabled on the channel). With digital calls, the calls continue to have the emergency bit set.
4. If the Surveillance Mode is enabled (see Section
4.7), all indicators, lights, and tones are disabled. If “No Receive Activity During Emergency” is programmed, receive audio, the front panel LED, and receive icons are disabled in the receive mode.
5. To exit this mode, cycle radio power or press and hold the Emergency switch.
5.10.4 EMERGENCY MAN-DOWN FEATURE
To have this feature, a special man-down switch (currently available only from third-party vendors) is attached to the accessory connector of the radio. Then if this feature is enabled by programming and the radio is in a horizontal position for longer than the programmed time (0-63 seconds), an emergency condition is triggered the same as if the Emergency switch was pressed. The emergency can be canceled by a press and release of the Emergency switch. Note that accessories such as speaker-microphones cannot be used with this feature.
5.11 CONVENTIONAL MODE SCANNING
5.11.1 GENERAL
Channel scanning features common to all oper­ating modes are described in Sections 4.8 and 4.9. The following information describes features unique to conventional operation.
31
CONVENTIONAL MODE FEATURES
5.11.2 TRANSMITTING IN SCAN MODE
Each conventional scan list can be programmed for one of the following modes. These modes deter­mine if priority sampling occurs and also the channel on which transmissions occur while scanning. Refer to the next section for more information on priority sampling.
No Priority - No priority channel sampling occurs when the list is selected. The radio transmits on the selected channel.
Priority/Tx Selected - Priority sampling occurs and the priority channel or channels are those programmed in the selected scan list. The radio transmits on the selected channel.
Priority/Tx Priority (1) - Priority sampling occurs and the priority channel or channels are those programmed in the selected scan list. The radio transmits on the priority (1) channel.
Priority (1) on Selected - The priority (1) channel is always the selected channel. The radio transmits on the selected channel.
Talkback - No priority sampling occurs. The radio transmits on the channel of a call while scanning is halted. Then once scanning resumes, it transmits on the selected channel.
5.11.3 PRIORITY CHANNEL SAMPLING
NOTE: The following describes priority sampling when scanning conventional channels. Priority sampling when scanning SMARTNET/SmartZone/P25 Trunked channels is described in Section 6.12.
General
The priority channel sampling feature ensures that when priority scanning, messages on the priority channel are not missed while listening to a message on some other channel. The radio can be programmed as just described so that the priority channel is a fixed channel programmed in the current scan list, the currently selected channel, or not used.
NOTE: The priority channel is not scanned if the active channel is an analog channel on the same
frequency as the priority channel and is programmed with CTCSS/DCS squelch control.
Either a single or dual priority channels can be programmed if desired. With dual priority, a call on the second priority channel is interrupted by a call on the first priority channel but not vice versa. When scanning and the selected channel is a single or first priority channel, is indicated in the display. This indication is displayed regardless of whether the priority channel is fixed or always the selected channel. When it is a second priority channel, is displayed.
2
The priority channel sampling frequency is deter­mined by the programmed Priority Lookback Time A (see description which follows). For example, if 2.0 seconds is programmed, the priority channel is sampled every 2.0 seconds when listening to a message on a non-priority channel. When not listening to a message, the priority channels are scanned in the normal scan sequence. With dual priority, the first and second priority channels are alternately sampled at the Lookback Time.
Priority channel sampling occurs only with conventional priority scanning. It does not occur with radio wide scanning, when listening to any type of SMARTNET/SmartZone/P25 trunked call, encrypted call, or when transmitting (see preceding note). A series of “ticks” may be heard when the priority channel is sampled while listening to a message on some other conventional channel.
The priority sampling times are programmed by the following parameters:
Lookback Time A - This time determines how often the priority channel is checked for activity. Times of
0.25-4.00 seconds in 0.25-second steps can be programmed.
Lookback Time B - This time determines how often the priority channel is checked once an incorrect Call Guard (CTCSS/DCS) or NAC code is detected. Since it takes much longer to detect an incorrect Call Guard signal than a carrier, this time should be relatively long to prevent the interruptions from making a message difficult to understand. Times of 0.5-8.0 seconds can be programmed in 0.5-second steps.
32
CONVENTIONAL MODE FEATURES
Changing the Priority Channel
If a fixed priority channel is associated with the current scan list, it can be changed if the Priority option switch or menu parameter is programmed. W ith dual priority, this function changes only the first priority channel. T o change both priority channels, use the Scan List Edit function described in Section 4.9.1.
Proceed as follows to change the priority channel using the Priority option switch/menu parameter:
1. Make sure scanning is disabled ( icon not
displayed) and the desired scan list is selected (see Section 4.9).
2. Select the channel you want to be the priority
channel and then press the Priority option switch or select that menu parameter. “Priority” is then flashed to indicate that the current channel is now the priority channel when scanning that list. Other indications that may occur are as follows:
If “No Priority” is displayed, priority sampling
may not be enabled on the scan list.
If “Sel Chan” is displayed, the priority channel is
always the selected channel and cannot be changed.
If no indication displayed, the scan list may not be
user editable or the channel may not be in the scan list.
5.12 STANDARD CONVENTIONAL CALLS
3. Press the PTT switch and if the Busy Channel Lockout feature is programmed on the channel (see Section 5.4), the transmitter is automatically disabled if the channel is busy . Oth erwise, busy and out-of-range conditions are not indicated.
4. Press (and hold) the PTT switch to talk and release it to listen.
Receiving a Standard Conventional Call
1. Select or scan the channel programmed for the call you want to receive (refer to Sections 4.8 and 4.9 for more scanning information).
2. When the call is received, press the PTT switch to talk and release it to listen. If scanning, responses may occur on the priority, selected, or receive channel as described in Section 5.11.2.
5.13 DTMF/ANI SIGNALING
DTMF (Dual Tone Multi-Frequency) tones can be generated for ANI (Automatic Number Identifica­tion) and other purposes on conventional analog channels. One of the following options may be enabled on each channel:
Pre-Tx ANI - A preprogrammed ANI sequence is automatically sent each time the PTT switch is pressed.
Post-Tx ANI - A preprogrammed ANI sequence is automatically sent each time the PTT switch is released.
Standard conventional calls are placed to other radio units monitoring the selected channel. The proper coded Call Guard squelch tone or code or P25 NAC may need to be transmitted by your radio for them to receive a call (see Sections 5.5 and 5.17.3).
Placing a Standard Conventional Call
1. Turn power on and set the volume as described in
Section 3.1. Select the channel programmed for the radio you want to call as described in Section 3.3.
2. Monitor the channel automatically or manually as
described in Section 5.2.
When an emergency alarm or call is placed, this ANI signaling is replaced by the Emergency DTMF ID (see Section 5.10). Refer to Section 5.15 for information on MDC1200 ANI.
5.14 SINGLE TONE ENCODER
This feature allows the user to transmit a single tone by pressing the Single Tone Encoder option switch or selecting that menu parameter. Each conven­tional system can be programmed for a tone of 500­2500 Hz in 1 Hz steps with a duration of 0.5-2.5 seconds in 0.1 second steps.
33
CONVENTIONAL MODE FEATURES
5.15 MDC1200 COMPATIBILITY
MDC1200 is a signaling protocol designed and implemented by Motorola for analog channels only. The following features of this protocol are supported. Either MDC1200 or standard DTMF ANI/Emergency signaling can be programmed on each conventional system.
MDC1200 ANI supported.
MDC1200 Emergency Alert implemented. Currently, ACKs are not decoded so the radio retrys the programmed number of times with each emergency.
5.16 CLONE MODE
5.16.1 GENERAL
The Clone feature enables one radio to program another with identical information. The PCConfigure programming software is not required. This feature is is not available with 53xx mobiles. Other requirements are as follows:
- Both pre and post ANI are
- A retry counter is
The Clone menu parameter must be enabled in the
master (sending) radio. This parameter is not required with the slave (receiving) radio.
The master and slave radios must be identical
models (same frequency range and options).
The wireless cloning feature utilizes the P25 data functionality of the radio. Therefore, a conventional P25 channel must be programmed in both radios and the slave radio must have been programmed with a P25 Unit ID. In addition, Data Registration must be enabled in both radios. If it is not programmed, “Disabled” is displayed. Radios with wireless cloning capability have a new selection in the cloning menu to select either Clone N (Normal) or Clone W (Wireless). If Wireless is selected, an additional menu is displayed for entering the P25 Unit ID of the destination radio (slave). The Zone/Complete mode is then selected.
5.16.3 CLONING PROCEDURE
1. With normal (non-wireless) cloning, connect the
master (sending) radio to the slave (receiving) radio using Cloning Cable, Part No. 023-5100-930.
2. On the master radio, select the Clone menu param-
eter and press the F2 key . If applicable, select either “Clone W” (Wireless) or “Clone N” (Normal). If normal cloning was selected or if this is not select­able, proceed to step 4.
3. With wireless cloning, a screen is then displayed for
entering the P25 Unit ID of the destination (slave) radio. Enter this ID using the keypad (or the Up/ Down keys) and F2.
4. The clone mode “Zone” or “Complete” is then
selected. Select the desired mode. Operation is as follows:
Only zones with conventional analog and P25 channels can be transferred using this function. Any SMARTNET/SmartZone and P25 trunked informa­tion is not transferred. In addition, the P25 Unit ID, encryption keys, and the RSI ID and other OTAR information are not transferred. Cloned zones are indi­cated in the slave radio by an asterisk in the first char­acter position of the zone alias (the first character is replaced by this asterisk).
5.16.2 WIRELESS CLONING
A new wireless cloning feature is available that allows one radio to program another using an RF link instead of having to be physically connected by a cloning cable. This feature is available on P25 conven­tional channels only.
Zone - This mode allows channel information for only the selected zone to be transferred. Informa­tion programmed on the Global, Radio Wide, and By System screens is not changed. A list of the current conventional zones is displayed. Select the desired zone by highlighting it and pressing the F2 key . A selected zone is indicated by an asterisk (*). Scroll to “OK” and press F2 to begin the data transfer. The selected zone in the slave radio is overwritten. Previously, multiple zones could be selected and they were appended to those in the slave radio.
Complete - This mode transfers all conventional programming information. This includes informa­tion on the Global, Radio Wide, and By System screens. Simply highlight “Complete” and press the
34
CONVENTIONAL MODE FEATURES
F2 key to begin the data transfer. This mode over­writes all this information currently in the slave radio. None of the previous information is retained except for the IDs as described in Section 5.16.1.
5.17 PROJECT 25 MODE FEATURES
NOTE: The following features are unique to conventional P25 channels.
5.17.1 UNIT ID CODE
Each radio that operates on Project 25 (digital) channels is programmed with an eight-digit unit ID. This ID is unique for each radio and can be any number from 1-16,777,216. When power is turned on with a Project 25 channel selected, this ID is briefly displayed.
5.17.2 GROUP ID CODE
Each Project 25 channel is programmed with a group ID that determines which group of radios will receive the call. A call is received on a channel if a selected or scanned channel is programmed with that ID and the correct NAC is detected (see following). Group IDs can be any number from 0-65,535. Group ID detect can be disabled by the Normal/Selective squelch function described in Section 5.5.2 or the monitor mode described in Section 5.3
5.17.3 NETWORK ACCESS CODE
Project 25 conventional channels also use a NAC (Network Access Code) to control which calls are received on a channel. The NAC can be 0-4095, and each transmit and receive channel can be programmed for a different code. Other operation, such as moni­toring before transmitting, is similar to that of analog channels. NAC (and group ID) detect can be disabled by the monitor mode described in Section 5.3.
5.17.4 P25 GROUP CALLS
P25 group calls are placed by simply selecting the channel programmed for the desired group, monitoring the channel if required, and transmitting.
also displayed for 0.5-7.0 seconds or continuously during the call.
P25 PTT ID- The unit ID of the radio placing the call is displayed.
P25 Talk Group - The alias of the talk group on which the call is being received is displayed.
User Group ID - If the group ID of the call being received is included in a preprogrammed User Group ID list, the alias programmed in that list for that group is displayed.
Changing a Channel Talk Group
If the Digital Talk Group Select option switch or Select TG menu parameter is programmed, the talk group assigned to a channel can be changed by the user. The new talk group continues to be assigned to the channel until it is manually changed again (cycling radio power or selecting another channel does not reselect a default talk group). Change the talk group assigned to a channel as follows:
1. Select the channel to be changed.
2. T o select the talk group from the list of programmed
talk groups, briefly press the Talk Group Select option switch or select the Select TG > ID List menu parameter. Then press the Up/Down switch until the alias of the desired talk group is displayed. If talk group selection has been disabled on the channel by programming, “NO LIST” is displayed, a tone sounds, and no change occurs. Press the F2 switch to select the talk group and return to normal operation.
3. To enter a new talk group number from 1-65,535,
press and hold the T alk Group Select option switch or select the Select TG > Enter ID menu parameter. Enter the desired talk group directly using the keypad. If less than five digits are entered, press the F2 switch to select the talk group and return to normal operation.
5.17.5 P25 UNIT CALLS
When a P25 group call is received, the alias (or frequency) of the selected channel is displayed. The radio can be programmed so that the following are
Unit Calls (also called Individual Calls) can be placed to a specific radio on a Project 25 channel if the Unit Call option switch or menu parameter is
35
CONVENTIONAL MODE FEATURES
programmed. Only the individual ID of the tar get radio is sent (a talk group ID is not sent). The radios that can be called are preprogrammed in the Unit Call list.
To receive a Unit Call, the RF channel of the call must be selected or scanned and the correct NAC and unit ID must be detected. The ID of the calling radio is then transmitted back. T o respond to the call, the radio must be programmed with the Unit ID option switch or menu parameter, and have a Unit Call programmed for the ID of the calling radio.
Place and receive a Unit Call as follows:
1. To transmit a Unit Call, press the Unit Call option
switch or select the Unit Call menu parameter. The alias (tag) of the last Unit Call is displayed.
2. If required, press the Up/Down switch to display the
desired call. The alias and ID of the calls that have been programmed are alternately displayed.
3. Press and then release the PTT switch. Ringing is
then heard and “WAIT” displayed to indicate that the radio is being rung. To disable this ringing but not the call, briefly press the PTT switch again. Ringing occurs for 20 seconds or until the call is answered, whichever occurs first.
4. When a Unit Call is received, two beeps sound (if
tones are enabled), and “Call Rcvd” and the alias of the unit ID are alternately flashed.
5. To respond, select the Unit Call mode by pressing
the Unit Call option switch or selecting the menu parameter. The following operation then occurs:
If a unit call has been programmed with the ID of
the calling radio, it is automatically selected. A response can then be made without changing the selected channel.
5.17.6 P25 CONVENTIONAL TELEPHONE CALLS
General
Telephone calls can be placed and received on P25 conventional channels. This feature allows tele­phone calls to be placed and received over the public telephone system using your radio. Telephone calls are programmed to operate in one of the following modes:
Disabled
Answer-only capability
List only - Telephone numbers can be selected
from a preprogrammed list only (direct entry using the keypad is not allowed)
Unlimited - Telephone numbers can be selected
from a list and also dialed directly entered using the keypad.
Both limited and DTMF keypad models can place telephone calls by recalling the telephone number from a preprogrammed list as just described. However, only DTMF keypad models can directly dial telephone numbers using the keypad.
Access/De-Access Codes
P25 conventional telephone calls utilize an access to access the system when placing a telephone call, and a de-access code to terminate the call when it is finished. These codes are preprogrammed in pairs by the Access/De-Access Code list selected on the conventional Per System screen, and up to 16 pair can be programmed. Each conventional P25 channel can be programmed to automatically select one of these code pairs. They must match the system codes, and the default code is *1P(pause)#.
Placing a Telephone Call
Recalling From List
If no Unit Call has been programmed with the ID
of the calling radio, a response cannot be made in this mode.
If the call timer times out (set by programming) or
the channel is changed before a response is made, the unit call mode is exited.
1. Select the conventional channel that is programmed
to select the desired access and de-access codes.
2. Momentarily press the Phone option key or select
the Phone > Num List menu parameter. The display indicates the last number dialed by alternately displaying “Last Num” and the telephone number.
36
CONVENTIONAL MODE FEATURES
In addition, the phone mode is indicated by the
icon.
3. If required, press the Up/Down switch to display the desired number. The alias and telephone number are alternately displayed.
4. Briefly press the PTT switch to send the access code. A dial tone sound should then be heard. Briefly press the P TT switch again to send the digits. Proceed to step 5.
Direct Entry Using DTMF Keypad
1. Select the conventional channel that is programmed to select the desired access and de-access codes.
2. Press and hold the Phone option key until a tone sounds (approximately 1 second) or select the Phone > Enter Num menu parameter. The alias of the last called telephone number is displayed if it is in the phone number list. Otherwise, only the last eight digits are displayed. In addition, the phone mode is indicated by the icon.
3. Enter the telephone number using the 0-9, keys. T o enter a pause (indicated by “P”), press The number scrolls to the left in the display so that the eight right-most digits are always displayed. Numbers up to sixteen digits (including pauses) can be entered.
4. Briefly press the PTT switch to send the access code. A dial tone sound then be heard. Briefly press the PTT switch again to send the digits.
5. Press the PTT switch to talk and release it to listen. Since the radio operates half duplex, it is not possible to talk and listen at the same time.
6. When the telephone call is finished or if it could not be completed for some reason, end it by pressing the Phone option key or F1 key. This sends the de­access code which tells the system that the call is finished and that the repeater can be released.
Answering a Telephone Call
1. When a telephone call is received, “ringing” similar to a standard telephone is heard and “PHONE” is displayed.
*, and #
* #.
2. T o answer the call, press the Phone option switch or select that menu parameter and press the PTT switch to talk and release it to listen.
3. When the call is finished, end it as in the preceding step 6.
5.17.7 CALL ALERT
General
The Call Alert™ feature allows pages to be sent and received on P25 conventional channels. Opera­tion is similar to SMARTNET/SmartZone and P25 Trunked channels.
Answering a Page
1. When a page is received, five beeps sound and
“PAGE” is displayed. The ID of the radio paging you is stored as the last ID received.
2. T o clear or ignore the page, press any option switch.
If the PTT switch is pressed, a group call is placed on the selected channel.
3. To answer the page as a unit call (see Section
5.17.5), press the Unit Call option switch or select that menu parameter and the alias of the radio paging you is displayed. Press the PTT switch and respond. One of the following conditions then occur:
If the radio being called is on the air, ringing is
heard until the called party answers or for 20
seconds, whichever occurs first. If no answer
occurs within 20 seconds, a continuous tone
sounds and “NO ANS” is displayed.
If the radio being called is not on the air, a contin-
uous tone is heard instead of ringing and “NO
ACK” is displayed.
4. When the call is finished or if it could not be
completed for some reason, end it by pressing the Unit Call option switch or the F1 (Exit) key.
Initiating a Page
1. With a P25 conventional channel selected, momen-
tarily press the Call Alert option switch or select that
37
CONVENTIONAL MODE FEATURES
menu parameter. The alias of the last ID called is displayed.
2. If required, press the Up/Down switch to display the desired radio. The alias of each number is displayed.
3. Press the PTT switch or the F2 key and one of the following occur:
If five beeps sound, the system received the page
and the paged radio is on the air and received it. The page mode is automatically exited.
If the system received the page but the called radio
is not on the air, a single beep sounds and “NO ACK” is displayed 6 seconds after the P TT switch is pressed. Auto exit then occurs.
5.17.8 MESSAGING
The messaging feature allows preprogrammed messages to be sent to a dispatcher on P25 channels. Up to 16 messages can be preprogrammed, and they are identified by an alias. If a Message option switch or menu parameter is programmed, messages are sent as follows:
tions can be preprogrammed, and they are identified by an alias. If the Status option switch or menu param­eter is programmed, status conditions are sent as follows:
1. Momentarily press the Status option switch or select that menu parameter. The alias of the current status condition is displayed.
2. To change the current status, press the Up/Down switch until the desired status is displayed. Then to send the status, press the F2 (Select) switch or momentarily press the PTT switch. One of the following events then occurs:
If five beeps sound and “ACK RCVD” is
displayed, the status was received and acknowl­edged by the system.
If after five tries the message is not acknowledged,
a tone sounds and “NO ACK” is displayed.
5.17.10 P25 PACKET DATA
P25 packet data transmission capability is avail­able with 4100 portables. A P25 Packet Data option button or menu parameter must be programmed to toggle the data mode on and off.
1. Momentarily press the Message option switch or select that menu parameter. The alias of the last message sent is displayed.
2. If required, press the Up/Down switch to display the desired message. Then send the message by pressing the F2 key or momentarily pressing the PTT switch. One of the following events then occurs:
If five beeps sound and “ACK RECVD” is
displayed, the message was received and automat­ically acknowledged by the system.
If after five tries the message is not acknowledged,
a tone sounds and “NO ACK” is displayed.
5.17.9 STATUS MESSAGING
The status messaging feature allows you to manu­ally or automatically send your current status to your dispatcher on P25 channels. Up to eight status condi-
The P25 Packet Data mode allows a subscriber unit to act as a packet data modem for a remote appli­cation connected to the subscriber unit via an RS-232 or SLIP (Serial Line Internet Protocol) connection. The SLIP connection requires an Ethernet port which is currently not available. The standard PCConfigure programming cable provides the RS-232 port (female DB9 connector) for connecting the external data equipment to a 4100 portable.
5.18 KEYPAD PROGRAMMING
NOTE: The Keypad programming feature is available to Federal Government users only. Users regulated by the Federal Communications Commission are not allowed to have this feature.
5.18.1 INTRODUCTION
Keypad programming can be enabled only if it has been enabled at the factory and a conventional mode option switch or menu parameter is programmed
38
CONVENTIONAL MODE FEATURES
for the “Keypad Programming” function. The keypad programming mode is indicated by “CHNG ZONE” and in the display.
Keypad programming allows conventional channel parameters such as the transmit and receive frequency, Call Guard squelch code, and encryption key to be changed. In addition, several conventional mode timers can be changed. It cannot be used to reprogram disabled channels or any SMARTNET/ SmartZone/P25 Trunked information.
Zone
Change
Select
Zone
F1 = Exit/Back F2 = Select
Up/Down = Scroll
* Analog Only
** Digital Only
*** Mixed Mode Ch Only
Channel Change
Select
Channel
Scan Hold Timer
Tx Timer
Penalty Timer
Conver. Timer
System
Parameters
Tx Freq
Squelch Adj*
Chan Spacing*
Key Select
Strapping
Talk Grp ID**
Chan Alias
Tx Tmr On-Off
Tx Power
Tx Code/NAC
Rx Code/NAC
Tx Type Sel***
Channel
Parameters
Rx Freq
Figure 5-1 Keypad Programming Menu
Flowchart
5.18.2 MENU DESCRIPTION
A menu system is used to select parameters in the keypad programming mode. A flowchart showing the keypad programming mode menu structure is located in Figure 5-1. When the keypad programming mode is selected by the Keypad Programming option switch or menu parameter, the first menu parameter “CHNG ZONE” is displayed as just described. Press the Up/
Down switch to scroll through the available parameters which are as follows.
CHNG ZONE
CHNG CHAN
SYS PARMS
CHAN PARMS
Press the F2 (Select) key to select a highlighted parameter, and press the F1 key from one of the main menus to exit keypad programming. Pressing it in the other menus returns to the previous menu. The Up/ Down switch is also used in several menus to scroll through available selections. Additional information on this parameters is located in the following sections.
5.18.3 ZONE PASSWORD
NOTE: Make sure that the zone password(s) are not lost because they cannot be overridden in the field. The PCConfigure software must be used to display the lost password or program a new password.
Each zone can be programmed with a password by the PCConfigure software to prevent unauthorized reprogramming of zone by keypad programming. When this password is programmed, it must be entered before system or channel parameters in that zone can be changed by keypad programming. The zone pass­word is programmed in the Zones > Edit Zone screen of the PCConfigure programmer. This screen is displayed by clicking the Edit Zone button. A dif ferent password can be programmed for each zone.
When an attempt is made to select a system or channel parameter in a password protected zone, “PASSWORD” is flashed. The password is always eight digits long and is entered using the same proce­dure as used for the power-up password described in Section 3.2. After the password is entered, system and channel parameters for that zone can be reprogrammed normally.
5.18.4 ZONE CHANGE PARAMETER
The “CHNG ZONE” menu parameter selects the zone containing the conventional channel to be repro­grammed. It does not change the zone selected for normal operation.
39
CONVENTIONAL MODE FEATURES
Press the F2 switch to select the “ZONE CHG” parameter and then scroll through the programmed zones by pressing the Up/Down switch. When the desired zone is displayed, select it by pressing the F2 switch.
5.18.5 CHANNEL CHANGE PARAMETER
The “CHNG CHAN” menu parameter selects the conventional channel to be reprogrammed. Disabled or SMARTNET/SmartZone/P25 Trunked channels cannot be selected. This does not change the channel selected for normal operation.
Press the Select switch to select the “CHNG CHAN” parameter and then scroll through the programmed channels by pressing the Up/Down switch. When the desired channel is displayed, select it by pressing F2 switch.
5.18.6 SYSTEM PARAMETERS
NOTE: If “PASSWORD” is briefly displayed when attempting to select a parameter, see Section 5.18.3.
The “SYS PARMS” menu parameter selects the conventional mode timers to be reprogrammed (see following). Press the F2 switch to select the “SYS PARMS” parameter and then press the Up/Down switch to display the desired parameter. Then press the F2 switch again to select it.
SCAN TIMER - Selects the Scan Hold timer. Press the Up/Down switch to increment/decrement the timer in 0.5-second steps from 0-7.5 or set it to 0 seconds to disable it. When the desired value is displayed, store it by pressing the F2 switch.
CONV TIMER - Selects the conversation timer. Press the Up/Down switch to increment/decrement the timer in 30-second steps from 0-450 or disable it by selecting 0 seconds. When the desired value is displayed, store it by pressing the F2 switch.
5.18.7 CHANNEL PARAMETERS
NOTE: If “PASSWORD” is briefly displayed when attempting to select a parameter, see Section 5.18.3.
The “CHAN PARMS” menu parameter selects the following conventional channel parameters that can be reprogrammed. Press F2 switch to select the “CHAN PARMS” parameter and then press the Up/Down switch to display the desired parameter. Then press the F2 switch to select it. The squelch control parameters are unique to the type of conven­tional channel selected (analog or Project 25).
NOTE: If a mixed mode channel is selected, both the Rx Code (analog) and Rx NAC (P25) can be programmed. In addition, if the Tx Type is Analog, a Tx Code is programmed, and if it is Digital (P25), a Tx NAC is programmed.
TX FREQ - Programs the transmit channel frequency. The digit being changed flashes, and press the Up/ Down switch to select the desired number for that digit or enter it using the keypad. Then press the F2 switch to move to the next digit if applicable. If an invalid frequency is entered, a beep sounds, “INVALID” is briefly displayed, and the number must be re-entered.
RX FREQ - Programs the receive frequency the same as the preceding TX FREQ.
TX TIMER - Selects the transmit time-out timer. Press the Up/Down switch to increment/decrement the timer in 15-second steps from 0-225 or disable it by selecting 0 seconds. When the desired value is displayed, store it by pressing the F2 switch.
PEN TIMER - Selects the penalty timer. Press the Up/Down switch to increment/decrement the timer in 15-second steps from 0-225 or disable it by selecting 0 seconds. When the desired value is displayed, store it by pressing the F2 switch.
SQ ADJ (Analog Only) - Changes the preset squelch setting on that channel. The default setting is “0” and values of –7 to +7 can be selected. Increasing this setting toward +7 causes the squelch to open sooner so that weaker signals can be received, and decreasing it toward –7 causes the opposite to occur.
NOTE: The channel spacing is not set with P25 chan­nels because it is always narrow, and the squelch cannot be changed because the setting is critical for proper receiver operation.
40
CONVENTIONAL MODE FEATURES
CHAN SPC (Analog Only) - Selects either wide or narrow band channel spacing on analog channels only. Press the Up/Down switch to select “WIDE” or “NARROW”, and when the desired setting is displayed, store it by pressing the F2 switch.
NOTE: The next two parameters are programmed only if the radio is programmed for encryption.
Key Select - Selects the encryption key for the channel if applicable. The key storage location of 0-15 or 1-16 is displayed. If no keys are programmed, “No Keys” is displayed. Refer to Section 10.2 for more information.
Strapping - Selects the encryption strapping mode for the channel as Clear, Secure, or Switched. Refer to Section 10.3 for more information.
TG ID (P25 Only) - Selects the talk group for the selected channel. Press F2 to display the current talk group ID and then press F2 again to enter a different ID from 1-65,535. This number must be entered directly using the DTMF keypad.
Channel Alias - Programs the alias for the channel (DTMF keypad models only). Up to ten characters can be entered. Press F2 once to display the current alias and then press it again to program a new alias. Alpha­numeric characters are programmed using the 0-9 keys. Pressing a key once enters the first letter on the key and then pressing it successive times enters the letters and the number on the key. For example, press the “2” key twice to enter “B”. Press the F2 key to move to the next position or press it twice to enter a space.
following choices. When the desired setting is displayed, store it by pressing the F2 switch.
Power High - High transmit power
Power Low - Low transmit power
Power SW - Switchable power selectable by the
High/Low power switch. This choice is not avail­able if that switch is not programmed.
CTCSS/DCS Squelch Control (Analog Channel)
TX CODE - Programs the transmit Call Guard
(CTCSS/DCS) code. The currently selected code and is initially displayed. Press the Up/Down switch to select the desired code type (CTCSS analog or DCS digital). Then press F2 to select it and enter the code number similar to programming a channel frequency as just described.
RX CODE - Selects the receive codes the same as TX CODE above.
NAC Squelch Control (Project 25 Channel)
TX NAC - Programs the transmit Network Access
Code (NAC) which can be any number from 0-4095. With later models, this number is displayed in hexadecimal from 000-FFF. The procedure is similar to programming a TX FREQ just described. If an invalid code is entered, a beep sounds, “INVALID” is briefly displayed, and the code must be re-entered.
RX NAC - Selects the receive NAC the same as RX NAC above.
TX TIMER - Enables or disables the time-out timer on the current channel. Press the Up/Down switch to select the on and off mode, and when the desired setting is displayed, store it by pressing the F2 switch.
TX POWER - Selects the desired power output level. Press the Up/Down switch to scroll through the
Transmit Type (P25 Mixed Mode Only) - If the selected channel is a mixed mode, analog and P25 channel, this selects the transmit type. Either Analog or Digital (P25) can be selected. This then determines if a Tx Code or Tx NAC is programmed above.
41
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
SECTION 6 SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
6.1 INTRODUCTION
An overview of the SMARTNET/SmartZone and
P25 Trunked operating modes is located in Section
3.9. The following information describes the features unique to these modes of operation. Refer to the “Radio Wide Features” section starting on page 20 for information on features common to all operating modes.
6.2 ANALOG AND DIGITAL OPERATION
Either analog or digital operation can be selected for communication on SMARTNET traffic channels. Each talk group can be programmed for either type of operation. Digital operation may be an optional feature.
6.3 VIEWING UNIT ID
When power is turned on with a SMARTNET/ SmartZone channel selected, the five-digit Unit ID from 1-65,535 is briefly displayed as IDxxxxx. When a P25 channel is selected, the eight-digit unit ID from 1-16,777,216 is briefly displayed (see Section 5.17.1).
6.4 STANDARD GROUP CALLS
6.4.1 INTRODUCTION
Standard group calls may be placed to another radio, group of radios, or a dispatcher, depending on programming. Most calls are probably this type. Proceed as follows to place and receive group calls:
3. Press the P TT switch and begin talking. An optional talk permit tone may sound to indicate when talking can begin. Events that may occur are as follows:
If in the secure mode and your radio is not
programmed with the proper encryption key, “KEYFAIL” is displayed and the call must be made in the clear mode or the proper key must be programmed.
If the busy tone sounds and “BUSY” is displayed,
the system is busy. Release the PTT switch and wait for the call back tone to sound. Then press the PTT switch within 3 seconds.
If a continuous tone sounds and “NO SYS” is
displayed, you may be out-of-range. Drive closer or away from shielding objects and try again.
If your unit ID is invalid, the call is being made to
an invalid group ID, or group calls are not enabled, “DISABLED ID” is displayed and an alert tone sounds.
If an attempt is made to change an analog call
from the clear to secure mode and there is no available secure channel, “NO SEC” is flashed, an error tone sounds, and the call is terminated.
If an attempt is made to change an analog channel
from the secure to clear mode, “SEC ONLY” is displayed, an error tone sounds, and the call is terminated. (Calls on digital channels can be changed if not strapped to clear or secure.)
6.4.2 PLACING A STANDARD GROUP CALL
1. Turn power on and set the volume as described in Section 3.1. Select the channel programmed for the talk group you want to call (see Section 3.3).
2. If the talk group is programmed for encryption and is not strapped to Clear or Coded, select the desired mode by pressing the Clear/Secure option switch or selecting that menu parameter . The status cannot be changed if the talk group is strapped to Clear or Coded. Refer to Section 10.3 for more information.
If the secure mode is selected by the Secure/Clear
option switch or menu parameter and an attempt is made to transmit on a channel strapped as clear , “Clear Only” is displayed and the transmitter is disabled. Likewise, if the clear mode is selected and the channel is strapped as secure, “Secure Only” is displayed and the transmitter is disabled.
6.4.3 RECEIVING A STANDARD GROUP CALL
Calls are received on only the talk group and/or
announcement group programmed for the selected
42
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
channel (with scanning disabled). When the selected channel is programmed with both Talk and Announce­ment groups, only the Talk and Announcement group IDs are detected. Other IDs in the Announcement group are detected only if no talk group is programmed.
When a group call is received, the alias of the selected channel is displayed. The radio can be programmed so that the following are also displayed for 0.5-7.0 seconds or continuously during the call.
PTT ID- The unit ID of the radio placing the call is displayed.
TG on Rx - The alias of the talk group on which the call is being received is displayed.
User Group ID - If the group ID of the call being received is included in a preprogrammed User Group ID list, the alias programmed in that list for that group is displayed.
6.5 PRIVATE (UNIT-TO-UNIT) CALLS
NOTE: With P25 Trunked operation, these calls are called Unit Calls, and they function the same as Enhanced Private Conversation calls described in the following information.
List only - Unit IDs can be selected from a prepro-
grammed list only (direct entry using the keypad is not allowed)
Unlimited - Unit IDs can be selected from a list
and also dialed directly entered using the keypad.
Both limited and DTMF keypad models can be programmed to recall the unit IDs from a prepro­grammed list. However, only DTMF keypad models can be programmed to directly dial unit IDs.
6.5.2 PLACING AN ENHANCED PRIVATE
CONVERSATION CALL
Recalling From List
1. Momentarily press the Private Call option key or
select that menu parameter and the alias of the last called radio is displayed. The private call mode is indicated by in the display.
2. If required, select another radio by pressing the Up/
Down switch until the alias of the desired radio is displayed.
3. Press the PTT switch of the F2 key to initiate the
call.
(Proceed to the bulleted list which follows Item 3 in the next section for events that may occur next.)
6.5.1 GENERAL
Private calls allow calls to be placed to a specific radio unit. Either the Enhanced Private Conversa­tion™ or standard Private Conversation modes may be programmed depending on the capabilities of the radio system. One difference between these call types is that the Enhanced type provides an indication that the called radio is not on the air and the standard version does not. Operation in each of these modes is described in the following information.
The Private Call option key is required to place these calls, and either that key or the Call Response option key is required to receive them. Private calls are programmed to operate in one of the following modes:
Disabled
Answer-only capability
Direct Entry Using DTMF Keypad
1. Press and hold the Private Call option key until a tone sounds (approximately 1 second). The last ID called is displayed, and the private call mode is indi­cated by in the display.
2. Using the 0-9 keys, dial the ID of the radio you are calling (five digits must be entered). T o erase the last digit, press the Down key , and to cancel the call, press the Private Call Option key again.
3. Press the PTT switch to initiate the call. If the entered number is valid, the display indicates the alias of the ID if it matches an ID in the call list. Otherwise, the ID you entered continues to be displayed.
Events that may then occur are as follows:
43
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
If the radio being called is on the air, “WAIT” is
displayed and ringing is heard until the called party answers or for 20 seconds, whichever occurs first. Pressing the P TT switch or an option key stops the ringing but not the call. When the call is answered, the voice of the called party is heard.
If the called radio does not answer within 20
seconds, a continuous tone sounds and “NO ANS” is displayed.
If the called radio is not on the air, a continuous
tone sounds instead of the ringing tone and “NO ACK” is displayed.
If the busy tone sounds and “BUSY” is displayed,
the called radio has answered the call but the system is busy. When the system is no longer busy, the call back tone sounds.
If your radio or the called radio is inhibited or not
programmed to make this type of call or for the requested secure mode, “Rspns Only” is displayed and an alert tone sounds.
3. Press the PTT sw or the F2 key to initiate the call.
(Proceed to the bulleted list which follows Item 3 in the next section for events that may occur next.)
Direct Entry Using DTMF Keypad
1. Press and hold the Private Call option key until a tone sounds (approximately 1 second). The last ID called is displayed, and the private call mode is indi­cated by in the display.
2. Using the 0-9 keys, dial the ID of the radio you are calling (all six digits). To erase the last digit, press the Down key, and to cancel the call, press the Private Call Option key again.
3. Press the PTT switch to initiate the call. If the entered number is valid, the display indicates the alias of the ID if it matches an ID in the call list. Otherwise, the ID you entered continues to be displayed.
Events that may then occur are as follows:
If your radio does not have the proper encryption
key, “KEYFAIL” is displayed and the call must be made in the clear mode by pressing the Clear/ Secure option key (if strapped to switchable). Otherwise, load the correct key.
4. When the call is finished or is not answered, end it by pressing the Private Call option key or the F1 (Exit) key.
6.5.3 PLACING A STANDARD PRIVATE
CONVERSATION CALL
Recalling From List
1. Momentarily press the Private Call option key or select that menu parameter. The alias of the last called radio is displayed, and the private call mode is indicated by in the display.
2. If required, select another radio by pressing the Up/ Down switch until the alias of the desired radio is displayed.
The called party answers the call.
The called party does not answer. Press the
Private Call option key or F1 (Exit) to end the call.
If the selected radio ID is not valid, “INVALID
ID” is displayed and an alert tone sounds.
If the radio system is busy, four low tones sound
and “BUSY” is displayed. When the system is no longer busy, the call back tone (four beeps) is heard and the channel is automatically acquired. Press the PTT switch to continue the call.
If the call is in the secure mode and the radio does
not have the proper encryption key, “KEYFAIL” is displayed and the call must be made in the clear mode by pressing the Clear/Secure option key or selecting that menu parameter (if strapped to switchable). Otherwise, load the correct key.
4. When the call is finished or if it is not answered, end it by pressing the Private Call option key or the F1 (Exit) key.
44
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
6.5.4 RECEIVING A PRIVATE CALL (ALL TYPES)
1. When a private call is received, “CALL RCVD” is
displayed and the call tone sounds once.
2. T o answer the call, press the Private Call option key
or select that menu parameter and then press the PTT switch and begin speaking. The unit ID of the calling radio is displayed. More information follows:
If the PTT switch is pressed before the Private
Call option key , the call is transmitted as a group call.
If private calls are not permitted (the Private Call
option key/menu parameter is not programmed), press the Call Response option key or select that menu parameter to answer the call.
The call must be answered within 20 seconds or it
is automatically terminated.
only DTMF keypad models can directly dial telephone numbers using the keypad. The keypad remains active during a call for overdialing DTMF digits.
6.6.2 PLACING A TELEPHONE CALL
Recalling From List
1. Momentarily press the Phone option key or select that menu parameter. The a lias of the last called tele­phone number is displayed. The interconnect call mode is indicated by in the display.
2. If required, press the Up/Down switch to display the desired number. The alias of each number is displayed.
3. Press and release the PTT switch and “DIALING” is displayed. Refer to the bulleted list following step 3 in the next section for events that may then occur.
Direct Entry Using DTMF Keypad
If the system is busy when a response is made,
“BUSY” is displayed and the busy tone sounds.
6.6 TELEPHONE CALLS
NOTE: Telephone calls are available in the P25 trunked mode only.
6.6.1 GENERAL
The telephone call feature allows telephone calls to be placed and received over the public telephone system using your radio. Telephone calls are programmed to operate in one of the following modes:
Disabled
Answer-only capability
List only - Telephone numbers can be selected
from a preprogrammed list only (direct entry using the keypad is not allowed)
Unlimited - Telephone numbers can be selected
from a list and also dialed directly entered using the keypad.
Both limited and DTMF keypad models can place telephone calls by recalling the telephone number from a preprogrammed list as just described. However,
1. Press and hold the Phone option key until a tone sounds (approximately 1 second). The alias of the last called telephone number is displayed if it is in the phone number list. Otherwise, the last eight digits of the last called telephone number are displayed. The interconnect call mode is indicated by in the display.
2. Enter the telephone number using the 0-9, keys. To enter a pause (indicated by “P”), press and then #. To erase the last digit, press the F1 key. The number scrolls to the left in the display so that the eight right-most digits are always displayed. Numbers up to sixteen digits (including pauses) can be entered. Press the Phone option key to cancel the call.
3. Press and release the PTT switch and “DIALING” is displayed. Events that may occur are as follows:
*, and #
*
If the access is successful, a dial tone sounds and
the dialed number is displayed and sent. Either ringing or a busy signal is then heard as with a standard telephone call. When the called party answers, press the PTT switch to talk and release it to listen (since the radio is half-duplex, it is not possible to talk and listen at the same time).
45
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
Each time the PTT switch is released, a go-ahead tone is sent to the landside party to indicate when they can respond. To dial a number after the connection is made, press the P TT switch and dial the number using the microphone keypad.
If the selected telephone number is not valid,
“INV ALID” is displayed and an alert tone sounds. Select a valid number.
If the system is busy, “BUSY” is displayed and
the busy tone sounds. The call will automatically proceed when the system becomes available.
If you are out-of-range or the radio cannot be
accessed for some reason, “NO PHONE” is displayed and an alert tone sounds.
If the interconnect call you are making or the
selected secure mode is not authorized, “REJECT” is displayed and an alert tone sounds.
If your radio does not have the proper encryption
key, “KEYFAIL” is displayed and the call must be made in the clear mode using the Clear/Secure option key or menu parameter (if encryption is selectable on the channel). Otherwise, load the proper encryption key.
6.7 CALL ALERT
6.7.1 GENERAL
The Call Alert™ feature allows pages to be sent and received. With SMARTNET/SmartZone opera­tion, either the Enhanced Private Conversation™ or Standard Private Conversation mode may be programmed depending on the capabilities of the radio system. With P25 Trunked operation, operation is similar to the enhanced mode.
6.7.2 ANSWERING A PAGE
1. When a page is received, five beeps sound and
“PAGE” is displayed. The ID of the radio paging you is stored as the last ID received.
2. T o clear or ignore the page, press any option switch.
If the PTT switch is pressed, a group call is placed on the selected channel.
3. To answer the page as a private call (see Section
6.5), press the Private Call option switch or select that menu parameter and the alias of the radio paging you is displayed. Press the PTT switch and respond. One of the conditions that follow may also occur:
4. When the telephone call is finished or if it could not be completed for some reason, end it by pressing the Phone option key or F1 (Exit) key.
6.6.3 ANSWERING A TELEPHONE CALL
1. When a telephone call is received, “ringing” similar to a standard telephone is heard and “PHONE” is displayed.
2. T o answer the call, press the Phone option switch or select that menu parameter and press the PTT switch to talk and release it to listen. Since the radio oper­ates half duplex, it is not possible to talk and listen at the same time.
3. When the call is finished, end it by pressing the PHONE option switch or F1 (Exit) key.
Enhanced Private Conversation Mode
If the radio being called is on the air, ringing is
heard until the called party answers or for 20 seconds, whichever occurs first. If no answer occurs within 20 seconds, a continuous tone sounds and “NO ANS” is displayed.
If the radio being called is not on the air, a contin-
uous tone is heard instead of ringing and “NO ACK” is displayed.
Standard Private Conversation Mode
If the radio being called is not on the air or does
not answer, you will simply not hear a response.
4. When the call is finished or it could not be completed for some reason, end it by pressing the Private Call option switch or the F1 (Exit) key.
46
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
6.7.3 INITIATING A PAGE
1. With a SMARTNET/SmartZone or P25 Trunked channel selected, momentarily press the Call Alert option switch or select that menu parameter. The alias of the last ID called is displayed.
2. If required, press the Up/Down switch to display the desired radio. The alias of each number is displayed.
3. Press the PTT switch or the F2 key and one of the following occur:
If five beeps sound, the system received the page
and the paged radio is on the air and received it. The page mode is automatically exited.
If the system received the page but the calle d
radio is not on the air, a single beep sounds and “NO ACK” is displayed 6 seconds after the PTT switch is pressed. Auto exit then occurs.
6.9 SENDING STATUS CONDITIONS
The status feature allows you to manually or automatically send your current status to your dispatcher. Up to eight status conditions can be prepro­grammed, and they are identified by an alias. If the Status option switch or menu parameter is programmed, status conditions are sent as follows:
1. Momentarily press the Status option switch or select
that menu parameter. The alias of the current status condition is displayed.
2. To change the current status, press the Up/Down
switch until the desired status is displayed. Then to send the status, press the F2 (Select) switch or momentarily press the PTT switch. One of the following events then occurs:
If five beeps sound and “ACK RCVD” is
displayed, the status was received and acknowl­edged by the system.
6.8 MESSAGING
NOTE: This feature is not available with P25 trunked operation.
The messaging feature allows preprogrammed messages to be sent to a dispatcher. Up to 16 messages can be preprogrammed, and they are identified by an alias. If a Message option switch or menu parameter is programmed, messages are sent as follows:
1. Momentarily press the Message option switch or
select that menu parameter. The alias of the last message sent is displayed.
2. If required, press the Up/Down switch to display the
desired message. Then send the message by pressing the F2 key or momentarily pressing the PTT switch. One of the following events then occurs:
If five beeps sound and “ACK RECVD” is
displayed, the message was received and auto­matically acknowledged by the system.
If after five tries the message is not acknowl-
edged, a tone sounds and “NO ACK” is displayed.
If after five tries the message is not acknowl-
edged, a tone sounds and “NO ACK” is displayed.
6.10 EMERGENCY ALARM AND CALL
6.10.1 INTRODUCTION
Emergency Alarms and Calls are separate func­tions that can be individually enabled or disabled on each SMARTNET/SmartZone and P25 Trunked system. The Emergency option switch (or menu parameter) is required for these functions. Other emer­gency features are as follows:
Emergency Alarms are transmitted on the selected
talk group if emergency calls are disabled, and on the emergency talk group if emergency calls are enabled.
Emergency Call talk group selection priority is as
follows. For example, if a global emergency channel is not programmed, the emergency talk group of the selected channel is used and so on.
1. Global (radio wide) emergency channel
2. Emergency group of the selected channel
47
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
3. Talk group of the selected channel
4. Announcement group of the selected channel
The emergency programming of the system to
which that emergency talk group is linked controls the emergency operation.
6.10.2 EMERGENCY ALARMS
An emergency alarm is a special transmission that alerts a dispatcher of an emergency situation. It is sent automatically by simply pressing Emergency option switch or selecting the Emergency menu parameter. The system to which the emergency channel is linked must have Emergency Alarms enabled. If not, Emer­gency Alarms are disabled. The alarm is sent on the control channel using Motorola proprietary signaling.
Proceed as follows to send an emergency alarm:
1. If required, select a channel of a system on which
Emergency Alarms are enabled and then press the Emergency option switch or select that menu parameter. The radio then automatically transmits the emergency alarm.
2. Either Normal or Silent operation can be
programmed. With the Normal mode, the red LED lights, the emergency tone sounds, and “EMERGNCY” flashes in the display. This indica­tion continues to flash until the alarm mode is ended (see step 4). If silent programmed or the Surveil­lance mode is selected (see Section 4.7), none of these indications occur. If “No Receive Activity During Emergency” is programmed, receive audio, the front panel LED, and receive icons are disabled in the receive mode.
3. When the emerge ncy alarm is acknowledged, “ACK
RCVD” is briefly displayed and the emergency acknowledge tone (two beeps) sounds. Silent opera­tion may also be programmed in which case no tone sounds and there is no indication that an acknowl­edgment occurred.
4. The radio continues to transmit this message until an
acknowledgment is received or the programmed number of attempts have been made. The emer­gency alarm mode is exited when radio power is
cycled or by pressing and holding the Emergency option switch.
6.10.3 EMERGENCY CALLS
General
An emergency call urgently requests access to a voice channel (an emergency tone usually does not sound at the console). An emergency call is placed by pressing the PTT switch after pressing the Emergency option button or selecting the Emergency menu parameter. If the Emergency Hot Mic feature is enabled, the emergency call is automatically trans­mitted without having to press the PTT switch (see following description). The system to which the emer­gency channel is linked must have Emergency Calls enabled.
Emergency Hot Mic
If Emergency Hot Mic has been enabled for emergency calls, automatic transmitting occurs with microphone audio unmuted without having to manu­ally press the PTT switch. The automatic transmit period is programmed for 10-120 seconds in 10­second intervals. If this feature or emergency calls are not enabled by programming, automatic transmitting does not occur. This feature is initiated only on the first press of the Emergency switch. Subsequent presses do not trigger automatic transmissions. To reset this function, the channel must be changed or power cycled.
Placing an Emergency Call
1. If required, select a channel of a system on which
Emergency Calls are enabled and press the Emer­gency option switch or select that menu parameter. The Emergency Alarm is then sent as described in Section 5.10.2 if applicable.
1. The emergency mode is indicated when “ACK
RCVD” is briefly displayed and then “EMERGNCY” and the emergency talk group are alternately displayed.
2. If the preceding Emergency Hot Mic feature is
enabled, the call is automatically transmitted without pressing the PTT switch. If it is disabled,
48
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
press the PTT switch and begin speaking as with a standard call.
3. All group calls which follow are then emergency calls (private, telephone, and call alert calls are not allowed). If the channel is changed, the call is made on the emergency talk group programmed for the new channel. If the Surveillance Mode is enabled (see Section 4.7), all indicators, lights, and tones are disabled. If “No Receive Activity During Emer­gency” is programmed, receive audio, the front panel LED, and receive icons are disabled in the receive mode.
4. To exit this mode, cycle radio power or press and hold the Emergency switch.
6.10.4 EMERGENCY MAN-DOWN FEATURE
This feature requires a special man-down switch (currently available only from third-party vendors) that is attached to the accessory connector of the radio. Then if this feature is enabled by programming and the radio is in a horizontal position for longer than the programmed time (0-63 seconds), an emergency condition is triggered the same as if the Emergency switch was pressed. The emergency can be canceled by a press and release of the Emergency switch. Note that accessories such as speaker-microphones cannot be used with this feature.
6.11 FAILSOFT OPERATION
If a failure occurs in the SMARTNET/Smart­Zone or P25 Trunked system so that it cannot be used, the system directs the radio to automatically enter the failsoft mode. When in this mode, “FAILSOFT” and the alias of the selected channel are alternately displayed. A failsoft tone may also be heard, depending on how the repeater is programmed.
6.12 SMARTNET/SMARTZONE/P25 TRUNKED SCANNING FEATURES
6.12.1 GENERAL
Scanning on a SMARTNET/Smartzone and P25 Trunked systems is called Priority Monitor Scan. The following are unique features of this type of scanning. For general scanning information applicable to all operating modes, refer to Sections 4.8 and 4.9.
Scanning is turned on and off by the Scan option
switch or menu parameter. Talk groups (channels) can be programmed so that scanning automatically starts when the talk group is selected (Autoscan).
When responding to calls in the scan mode, the
programming of the T alkback Scan parameter deter­mines if a response always occurs on the talk group of the call (Active Group) or the Selected Group if they are different. Transmissions at other times always occur on the selected talk group.
Each talk group can be programmed to select one of
the programmed scan lists or “No List” (scanning is disabled). If scanning is enabled and the selected channel does not permit scanning, it is automatically enabled again when a channel is selected that permits scanning.
Up to 256 scan lists, each with up to 512 talk groups
from the same system can be programmed. The selected scan list can be temporarily changed and edited as described in Section 4.9.1.
In addition to calls on channels in the scan list,
pages, private/unit calls, and telephone calls are received while scanning. Private and telephone calls are not interrupted by priority messages.
When in the failsoft mode, operation is in the conventional mode on the preprogrammed failsoft channel (a different failsoft channel can be programmed on each talk group). If a transmission is attempted before a failsoft channel is located, a contin­uous tones sounds until the PTT switch is released. When the radio system returns to normal operation, this is automatically detected and normal operation resumes.
6.12.2 PRIORITY TALK GROUP SAMPLING
One talk group in the scan list can be designated a priority talk group by programming or it can be the selected talk group. When scanning, messages on a non-priority talk group are interrupted by messag es on the priority talk group. Priority scanning must also be supported at the system level for it to occur as programmed in the radio.
49
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
6.13 DYNAMIC REGROUPING
The dynamic regrouping feature allows a dispatcher to change the current talk group or switch radios to a predefined regrouping channel to receive an important message. When the console issues a regroup order, the radio switches to the preprogrammed regroup talk group.
If the Cancel Dynamic Regrouping option switch or menu parameter is programmed, it can be used to exit the dynamic regrouping mode if desired.
Otherwise, if the lock mode was not specified, the selected talk group can be manually changed and the previous talk group is reselected if power is cycled. If a locked regroup command is received, the displayed talk group cannot be changed manually or by cycling power. It can be changed only after a clear order is received from the console.
Dynamic regrouping operates as follows:
trunked site or roaming between several trunked sites. Operation in these modes is the same as just described in the preceding sections (6.1-6.13) with the following additional features:
6.14.2 BUSY OVERRIDE
The busy override feature is enabled at the syst em level by the system manager and is not a program­mable radio feature. It allows a call to be placed even if not all sites you are calling have a free traffic channel. The only sites guaranteed to be included are the Critical Sites and the sites where a Critical User is located. This feature operates as follows:
1. Assume that you have attempted to place a call and
the system was busy (“BUSY” displayed and busy tone sounded).
2. Release the PTT switch and then press it for 5
seconds or more. If a chirp tone sounds with the P TT switch pressed, busy override is occurring.
1. When this command is received, alternating tones sound and the radio automatically changes to the regrouping channel and “DYN REGRP” is displayed.
2. Manually select the channel corresponding to that alias. If this is not done, transmission still occurs on the new channel, but the alternating tones sound each time the PTT switch is pressed.
3. T alk and listen as usual. When dynamic regrouping is canceled by the dispatcher, a short tone sounds. If a standard channel is not selected after this occurs, transmission is not allowed if the talk group is assigned as a dynamic regrouping talk group only . If it is assigned as a normal talk group, normal trans­missions are allowed.
6.14 SMARTZONE AND P25 TRUNKED
UNIQUE FEATURES
6.14.1 INTRODUCTION
As described in Section 3.9.3, the SmartZone
®
mode provides wide area coverage by allowing roaming between SMAR TNET and conventional sites. The P25 Trunked mode can provide access to a single
NOTE: Remember that not all members of the talk group are receiving your message. Missing members will start receiving your message as channels become available.
6.14.3 SITE TRUNKING
Site trunking occurs when a site can no longer participate in wide area trunking. It is disconnected from other sides and only supports calls with other radios on that site and cannot route audio to other sites. When site trunking is occurring, the radio searches for other sites that may provide wide area coverage.
Site trunking ends when a wide area coverage site is located, the current site is operating again as a wide area coverage site, an out-of-range condition occurs, or the failsoft mode is entered. The radio can be programmed so that “Site Trunking” is displayed and/ or an alert tone sounds when site trunking occurs.
SmartZone and P25 trunked systems can be programmed for “Disable Site Trunking Operation”. The radio is then not allowed to start or operate on a site trunking site. If a site goes into site trunking, the radio leaves that site’s control channel and attempts to
50
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
find another valid wide area site. If no wide area site is available, the radio displays “Out-of-Range”. If a site adjacent to the current Home Site was in site trunking but then enters wide area trunking, it is evaluated to determine if it should move to that site as a better site.
6.14.4 DETERMINING CURRENT SITE AND SEARCHING FOR NEW SITE
T o display the RSSI level of the current site, press the Site Search option switch or select that menu parameter. The display then indicates the current site number as “SITE xx” and the RSSI level as “RSSI xx”. This mode is then automatically exited.
To scroll through the other programmed sites, press and hold the Site Search option switch while “SITE xx” or “RSSI xx” is displayed. If site lock is on when site search is entered (see following), the radio will be locked on the new site when this function is exited.
6.14.5 LOCKING/UNLOCKING A SITE
It is sometimes desirable to stay on a site. To prevent the radio from searching for a new site, lock it on the current site by pressing the Site Lock option switch or selecting that menu parameter. The display then momentarily indicates the site alias to indicate that the current site is locked (“x” is the current site number). T o unlock the site, press the Site Lock switch again or the F2 (Select) key and “UNLOCK” is momentarily displayed.
6.14.6 ZONEFAIL SITE LOCK
This is an optional feature that can be enabled only by factory programmed. It is not programmed by the PCConfigure software, and does not require any special inputs from the infrastructure to operate. This feature is intended to prevent some of the confusion resulting from a site controller failure. When this occurs, all sites go into the Site Trunking mode and radios continue to roam normally according to RSSI level. The result is that the various radios selected by a particular talk group may be operating on different sites and are unable to talk to each other (see Section
6.14.3 for more Site Trunking information).
zone controller is active. However, if the zone controller fails, this is detected and the Zone Fail Site Lock mode is entered. The only site the radio is then allowed to operate on is its home site. If its home site is not available, “Out-of-Range” is displayed. A zone controller failure is detected by determining that every site in the dynamic site list is in Site Trunking. Currently , this condition must be detected for at least 1 minute for the Zone Fail Site Lock mode to be selected.
The result of this operation is that all radios with the same programmed home site are forced to the home site to communicate which ensures that they can continue to communicate. If the home site is not avail­able, the Out-of-Range condition tells the user to attempt communication on another system or by some other means.
6.14.7 P25 WIDE AREA SCAN
Introduction
This feature is intended to enhance roaming performance, especially when system level steering via radio or talk group permissions is used.
Normal P25 and SmartZone Control Channel Hunt
The following control channel search methods are normally used to find a control channel:
Short Hunt - The dynamic array of 7 (or 15) adja­cent sites is searched. This list is saved on power down and loaded again at power up. It is erased whenever parameters are downloaded to the radio by the PCConfigure programmer.
Long Hunt - If no valid control channel is located by the preceding short hunt method, the radio searches the list of control channels programmed into the radio by the PCConfigure programmer.
Full Spectrum CC Scan - If the two preceding methods do not locate a control channel, every channel available to the radio is searched.
Talkgroup Steering Via System Access Permissions
With the Zone Fail Site Lock feature enabled, the
radio continues to roam normally when the system
In order to use system channel resources more efficiently, some system operators are using system
51
SMARTNET/SMARTZONE/P25 TRUNKED FEATURES
access permissions to steer certain talkgroups to particular sites. For example, a police department may be allowed to use only Site 1, and a public works department may be allowed to use only Site 2.
The problem with this operation is that every time a different talk group is selected, the access permission may be different and a different site may need to be accessed. This could result, in a worst case, in a delay of up to 30 seconds in finding a new site. This could occur if there are no valid sites for the new talk group in the dynamic site list.
P25 Wide Area Scan
A feature called Wide Area Scan can be programmed to minimize the problem just outlined. This feature is programmed on the Talk Group list screen selected on the P25 System screen. When Wide Area Scan is selected, talk group site preferences are no longer available. However, System Site Preference lists can still be used. The Wide Area Scan feature functions as follows:
1. Assume TG1 is selected. If it is the first time this
talk group is selected, normal searching for a control channel occurs according to the hunt methods previously described.
2. When another talk group is selected, the active valid site for TG1 is stored in EEPROM memory.
3. The next time TG1 is selected, the following proce­dure is performed before performing the normal hunt methods previously described.
a. The last valid site ID and its receive and transmit
channel numbers are loaded from EEPROM memory.
b. The dynamic site list is checked to see if any
newer receive/transmit channel information is available for the last site ID.
c. The best receive/transmit information is used and
the radio checks to see if this control channel is available.
The result of the preceding operation is that the radio has a reasonable chance of finding a valid site, usually on the first try. This greatly reduces access time, even on systems which have highly restricted talk group based access.
52
SECTION 7 MISCELLANEOUS
MISCELLANEOUS
7.1 SUPERVISORY TONES
Single Beep (Alert Tone)
Power was turned on and a successful power-up
sequence occurred (Section 3.1).
The time-out timer is about to expire or the penalty
timer has expired (Section 4.3).
The conversation timer is about to expire (Section
5.7).
The system received your page but the paged radio
is not on the air (Section 6.7).
Telephone interconnect is not operational (Section
6.6).
Continuous Tone (Invalid Condition)
A transmission is being attempted on a conventional
channel programmed as receive-only.
The transmitter is disabled by the busy channel
lockout feature (Section 5.4).
The transmitter has been disabled by the time-out
timer feature (Section 4.3).
The transmitter has been disabled by the conversa-
tion timer (Section 5.7).
An out-of-range condition exists (SMARTNET/
SmartZone and P25 trunking only).
A transmission is being attempted before the penalty
timer has expired (Section 5.6).
Dynamic regrouping has been exited but the
dynamic regrouping channel is still selected (Section 6.13).
Single Short Medium-Pitch Tone
A valid key has been pressed.
Single Short Low-Pitch Tone
An invalid key has been pressed.
The message that was sent has not been acknowl-
edged (Section 6.8).
The status condition that was sent has not been
acknowledged (Section 6.9).
Five Beeps (Recurring)
The page was received (Section 6.7).
Two Short Tones
A private call was received (Section 6.5).
Five Beeps
The paged radio received the page and acknowl-
edged it (Section 6.7).
The message that was sent has been received and
acknowledged (Section 6.8).
The status condition that was sent has been received
and acknowledged (Section 6.9).
Four Beeps
The emergency alarm condition was acknowledged
(Section 6.10).
Four low tone beeps indicate call back mode (the
system is no longer busy)
Alternating Tone
Dynamic regrouping has occurred (Section 6.13).
Dynamic regrouping has occurred but the
regrouping channel is not selected (Section 6.13).
Busy Signal
The radio system is busy or a busy condition exists
when making a telephone call.
Medium Tone (No Acknowledge)
The paged radio did not acknowledge the page
(Section 6.7).
Three Medium Pitch Tones
A channel is available after a busy condition
occurred (SMAR TNET/SmartZone only).
53
MISCELLANEOUS
7.2 ERROR MESSAGES
The following are definitions of the various error
messages that may be displayed.
Aff Failed - A group affiliation attempt has received a F AILED response from the system. The precise reason for a FAILED response is manufacturer dependent.
Aff Deny - A group affiliation attempt has received a DENIED response from the system. The precise reason for a DENIED response is manufacturer depen­dent. One common cause is that the group is disallowed on the site/RFSS that the radio is attempting to affiliate on.
Aff Refusd - A group affiliation attempt has received a REFUSED response from the system. The precise reason for a REFUSED response is manufacturer dependent.
Answr Only - The user has attempted to initiate a private call or interconnect call and the feature is programmed for answer only.
Bad Band - A profile/or user parameters have been downloaded with PCConfigure that are for a band different from the hardware of the radio.
Bad ESN -The ESN of the radio is not valid. This error is usually only seen in the factory when first programming brand new logic boards.
Bad Fl Fmt - A profile/or user parameters have been downloaded to the radio that do not match the file format supported by the firmware/software in the radio.
Bad Hrdwar - The ESN of the radio is not valid. This error is usually only seen in the factory when first programming brand new logic boards.
channel grant before the busy time-out timer has expired
Disabled - The selected channel is disabled.
Clear Only - The selected channel or group is
strapped clear only and that a secure call can not be made.
Corupt Prm - The radio has detected that its profile/ user parameters are not valid because the functional blocks can not be identified.
Denied - A group call attempt has received a DENIED response from the system.
Deny - A unit or interconnect call attempt has received a DENIED response from the system.
Disabled - The feature that the user is attempting to use has been disabled on the radio either by program­ming or by factory options.
DSP Failed - The main processor and the DSP have failed to complete their startup procedure at powerup.
EEPRM Fail - The main processor has timed out while trying to validate or invalidate the profile/user parameters in the EEPROM.
Encryp Bad - The main processor and the Encryption Module have failed to complete their startup procedure at power up.
Fixed High - The selected channel or group is strapped to high power and thus low power can not be selected.
Fixed Low - The selected channel or group is strapped to low power and thus high power can not be selected.
Batt Low - The battery voltage has been detected as being low.
Busy - A call has been attempted and the system has responded that no channels are available for assign­ment.
Busy Tmout - The radio previously received a busy response from the system and it has not received a
To o Hot - The mobile has passed the hot temperature threshold. Under these conditions the radio will only transmit in low power.
Invalid - The received input from the user does not fit the criteria necessary for the feature.
Invalid ID - The received ID from the user was not a valid ID.
54
MISCELLANEOUS
Invald Key - The key pressed by the user was not valid for the current situation.
Invld Ch - The channel entered by the user in keypad programming is not valid.
Key Fail - The encryption key required by the current selected group/channel is not valid.
Kypd Lockd - The keypad lock function is active and key presses are not accepted in this mode.
Kset Fail - The encryption key set chosen by the user is not valid.
List Only - Direct entry of a unit ID or phone number is disabled.
Locked - A selector lock command has been received and zone and channel changes are not accepted.
Lost Signl - Signal from the infrastructure has been lost during an interconnect call.
Low Power - The current channel is strapped to low power and that the user can not select high power at this time.
No Service - OTAR service is not available.
No Site - No site with a verified ID is yet on the
dynamic site list.
No Keys - No keys are available for the key select function.
Out Of Rng - This error indicates no control channel has been found for trunking operation.
Parms Fail - The checksum of the profile / user parameters does not match the calculated checksum. This indicates that there is an error in the parameters file. This message only occurs if the redundant copy of the parameters is also corrupt or is unable to be used.
Rekey Fail - This error indicates a failure in a rekeying process.
Rx Only - The selected channel is Rx only.
Sts Failed - No acknowledgement was received while
sending a status report.
Timeout - A time out has occurred in attempting the current function.
Msg Failed - The current channel is strapped to low power and that the user can not select high power at this time.
Narrow - The current conventional channel is programmed as a narrow channel.
No Ack - The radio did not receive an ACK for the current signaling attempt.
No Edit - The current list is not able to be edited.
No Encrypt - Encryption is not available for the
selected channel.
No List - No list is available for the selected channel.
No Message - No message is programmed for trans-
mission.
No Reply - Radio cloning failed due to no response.
Too Hot - The mobile has passed the TOO HOT
temperature threshold. Under these conditions the radio will not allow Tx.
Tx Timeout - The Tx time-out timer has expired and Tx has been terminated.
VOLTAGE HI - The input voltage to the mobile is too high.
VOLTAGE LO - The input voltage to the mobile is too low.
Write Fail -
The radio is unable to write to the
EEPROM.
7.3 SYSTEM OPERATOR PROGRAMMING
As noted several times in this manual, program­ming determines the availability and specific operation of many features. This usually refers to the program­ming performed by the PCConfigure programmer
55
MISCELLANEOUS
when the radio was set up, not to any programming a user can perform. If a feature is controlled by a front panel option switch and that switch is not available, it is probably not available.
If the Keypad Programming option switch is available, you can reprogram some conventional channel parameters. Refer to Section 5.18 for more information.
7.4 SPEAKING INTO MICROPHONE
For best results, hold the radio about 1-2 inches from your mouth and speak at a normal conversational level. Do not shout since it distorts your voice and does not increase range. Make sure that the PTT (push­to-talk) switch is pressed before you begin to speak and released as soon as the message is complete.
7.5 OPERATION AT EXTENDED RANGE
When approaching the limits of radio range, the other party may not be able to hear your transmissions and there may be an increase in background noise when messages are received. You may still be out of range even though you can hear a message. The reason for this is that the signal you are receiving is usually transmitted at a higher power level than the one trans­mitted by your radio. Communication may be improved by moving to higher ground or away from shielding objects such as tall buildings or hills.
7.6 LICENSING
A government license is usually required to operate this radio on the air.
7.7 RADIO SERVICE
If the radio is not responding to any key presses, the keypad may be locked. Refer to Section 3.6 for more information.
If “PASSWORD” is briefly displayed when power is turned on and you are prompted to enter a password, the Power-Up Password feature is enabled. Refer to Section 3.2 for more information.
If “UNPROGRAMD” is displayed, the cause could be any of the following:
An unprogrammed channel is selected. Select a
programmed channel.
The selected channel is programmed for an option
that is not installed or an error in programming was detected. Reprogram the radio.
If no characters appear in the display, the battery may be discharged or defective. Try another battery . If some other problem is occurring, turn power off and then on again to reset the control logic. Also make sure that the controls are properly set. If it still does not operate correctly, return it for service.
NOTE: There are no user-serviceable components in the radio. Altering internal adjustments can cause illegal emissions, void the warranty, and result in improper operation that can seriously dama ge the radio.
56
DETERMINING AVAILABLE OPTIONS
SECTION 8 DETERMINING AVAILABLE OPTIONS
8.1 GENERAL
This manual describes the operation of all features that are currently available for the 41xx radio. However, many of these features are optional and therefore may not be available in your radio. For example, Project 25 trunked operation is optional and may not be available.
Availability of optional features is controlled by factory programming of the control logic. Only those features that are specifically ordered and enabled in a particular radio are available for use and can be programmed. The features controlled by factory programming are as follows:
P25 Options
P25 conventional data
P25 trunked data
P25 conventional operation
P25 trunked operation
DTMF Keypad support (4100 only)
Zonefail site lock
[1] 4100 radios require that this option be enabled to roam
across zone controller boundaries.
Currently, the only operating mode that is stan­dard with all models is the conventional analog mode. Other variables such as frequency range are hardware dependent instead of software dependent.
8.2 UPGRADING A RADIO WITH NEW
OPTIONS
The capability exists to upgrade radios in the field with new features. A new feature can be purchased and a special encrypted code string keyed to the ESN (Electronic Serial Number) of the radio is then provided by the E.F. Johnson Company. This string is in the form of a computer file, and is downloaded to the radio using the PCConfigure programming soft­ware. This is initiated by clicking the “Update Options” button on the Radio Options screen shown in Figure 8-1.
Encryption Options
DES
DES-XL
DES-OFB
AES
OTAR Options
OTAR P25 conventional
OTAR P25 trunked
Trunking Options
STAR roaming with P25 trunked operation [1]
SMARTNET analog operation
SmartZone analog operation
Digital SMARTNET/SmartZone
Feature Options
Keypad programming (Federal Gov’t users only)
512 channels/talk groups (41xx only, currently
standard)
8.3 USING PCCONFIGURE TO DETERMINE
OPTIONS
To determine what software options have been enabled in a particular radio, it is recommended that you use the PCConfigure™ programming software to read and display what options are installed. Proceed as follows:
1. Connect the computer to the radio and start the
program as described in the documentation included with the PCConfigure software.
2. Select the 41xx radio type by selecting menu
parameter Radio > Series > 4100 Portable.
3. To display the Radio Options screen shown in
Figure 8-1, select Transfer > Read Options From Radio.
4. The check boxes indicate which options are enabled
in the radio. They are for informational purposes only and cannot be edited.
57
DETERMINING AVAILABLE OPTIONS
Examples
The following are examples of items that need to
be checked to program various optional features:
P25 Conventional Operation with DES Encryption and OTAR
P25 Options
- Digital Conventional, Conventional
Radio Data Encryption Options OTAR Options
- P25 DES OFB
- Conventional
P25 Trunked Operation with DES Encryption
P25 Options Encryption Options Trunking Options
- Digital Conventional
- P25 DES OFB
- P25 Trunking
SMARTNET Analog and Digital Operation with Encryption
P25 Options Encryption Options
- Digital SMARTNET/SmartZone
- DES Securenet and DES-
OFB
Trunking Options
- SMARTNET Trunking
NOTE: The “Feature Disable Options” are currently not used, so those features are always available.
Figure 8-1 PCConfigure Radio Options Screen
58
PASSWORD DESCRIPTION
SECTION 9 PASSWORD DESCRIPTION
9.1 NEW PASSWORD ENHANCEMENTS
9.1.1 INTRODUCTION
A new enhanced password feature is now avail­able for 4100 portables and 4300 mobiles. The number of passwords have been increased along with the number of functions that can be under password control. The single Power-On password has been replaced by the following passwords:
Four Power-On (User x) Passwords
Download and Upload Passwords
Master Password
9.2 PROGRAMMING PASSWORDS
9.2.1 GENERAL
With new versions of PCConfigure, the “Pass­word at Power Up” parameter has been removed from the Global screen as just described. Passwords are now programmed using a password management screen displayed by the Tools > Password Management menu. The applicable radio must be connected to the computer and powered up to display this screen.
following). If even the Master password is lost or was not used, all passwords can be erased using the PCTune software as follows:
1. With PCT une 1.1.1.0 or later , simply select Radio > Reset Passwords. Only password information is erased.
2. With earlier versions of PCTune, after starting the PCTune program, press SHIFT CTRL E to toggle the following Erase EEPROM function (otherwise it is grayed and not selectable). Then Select Radio > Erase EEPROM > Params Only. All password and personality information is erased, so the radio must be reprogrammed. NOTE: DO NOT SELECT
“COMPLETE” because that erases all information and the radio must then be sent back to the factory to make it usable again.
9.2.3 CHANGING PASSWORD
An assigned password can be changed by the user if the “Set User Password” option switch or menu parameter (4100 only) is programmed. Selecting this function displays prompts for entering and confirming a new password.
Password data is transferred and stored in an encrypted format for security purposes. In addition, actual passwords are never displayed. They are always indicated by eight asterisks (********). Therefore, it is not possible to determine what passwords are in a radio using the PCConfigure software.
Passwords must be 1-8 characters in length and consist of the numbers 0-9. Zeros are valid characters in any location, even as leading characters. Initially, all passwords are null (deleted) characters. Therefore, when initially programming a password, no entry is required in the “Original/Master Password” box.
9.2.2 LOST PASSWORDS
If a password is lost, it can be changed using PCConfigure by entering the Master password (see
NOTE: With the 4100 portable and 4300 Handheld Control Unit, it is r ecommended that a number key not be used for this function because the password mode is exited if that key is pressed to enter a number.
9.2.4 PASSWORD ENTRY PROCEDURE
Whenever a password is requested, it is entered as
follows:
43xx Mobile
41xx Portable each number using the keypad and press the F2 (Enter) key after the last digit is entered. With limited keypad models, enter each number by pressing the Up/Down switch and press the F2 key after each digit.
59
- Rotate and press the Select switch.
- With DTMF keypad models, enter
PASSWORD DESCRIPTION
9.3 PASSWORD DESCRIPTION
9.3.1 USER (POWER-ON) PASSWORDS
When a User Password is enabled, it must be entered each time radio power is turned on. Up to four different User Passwords (User 1/User 2/User 3/ User 4) can be programmed. Currently, the same radio features are enabled for each. Entering any User Pass­word at power up enables normal radio operation.
9.3.2 DOWNLOAD/UPLOAD PASSWORDS
Separate Download (write) and Upload (read) passwords can be programmed to prevent unautho­rized downloading or uploading of radio programming parameters. When one or both of these passwords are used, the proper password must be entered to perform the operation. A “User” password is not required to upload or download parameters.
9.3.3 MASTER PASSWORD
The Master Password overrides all the preceding passwords. It can be used by a system administrator as a “pass key” to a password controlled function or to change a lost or inadvertently changed password. Master passwords are set up and changed the same as
the other passwords. It does not override the following Zone Password.
9.4 ZONE PASSWORD
NOTE: The programming and usage of this password has not changed. It is independent from the preceding passwords, and programmed in the Zone > Edit Zones and Channels screen.
A zone password can also be programmed with the 43xx mobile and 41xx portable. It prevents unau­thorized reprogramming of zones by keypad prog ram­ming. When this password is used, it must be entered before system or channel parameters in that zone can be changed. The zone password is programmed in the Edit Zones and Channels screen. This screen is displayed by clicking the Edit Zone button on the Zone screen.
A different password can be programmed for each zone. When a password protected zone is selected, “PASSWORD” is flashed the first time an attempt is made to select a system or channel parameter in that zone. Each digit of the password is then entered as previously described. The password is always eight digits long, and after the eighth digit is entered, system and channel parameters for that zone can be reprogrammed normally.
60
SECURE COMMUNICATION (ENCRYPTION)
SECTION 10 SECURE COMMUNICATION (ENCRYPTION)
10.1 GENERAL
10.1.1 INTRODUCTION
This radio may be equipped to provide secure communication on some or all channels. This feature encrypts the voice so that it can be understood only by someone using a radio equipped with a similar encryp­tion device and encryption codes.
When a secure call is received or transmitted,
is indicated in the display (see Section 10.2.7). If
equipped with the Clear/Secure option switch and the current channel is programmed to allow switch selec­tion, secure communication can be manually enabled and disabled by that switch. Otherwise, channels are strapped to Clear or Coded operation (see Section
10.3). Secure communication can be programmed on a per channel or per talk group basis to operate in various ways. More information follows.
10.1.2 ENCRYPTION ALGORITHMS
DES-OFB - A form of DES encryption for digital
channels that uses output feedback. This protocol does not result in the degraded range that occurs with analog channels.
AES (Advanced Encryption Standard)
A new encryption standard called AES is replacing DES-OFB encryption on digital (P25) chan­nels. It uses a 128-, 192-, or 256-bit encryption key instead of the 64-bit key used with DES. EFJohnson radios currently support only 256-bit AES keys. The type of encryption (DES or AES) is determined by the type of encryption key that is loaded (see Section
10.2), and not by the PCConfigure programming soft­ware. AES encryption, like DES encryption, is an optional radio feature that must be purchased and then enabled at the factory.
SecureNet™
SecureNet encryption digitizes the voice and then encrypts it using the DES or DVP algorithm. It uses a 64-bit encryption key. The SecureNet protocols include the following algorithms:
DVP (Digital Voice Privacy) is an earlier encryption
method that is self synchronizing using cipher feed­back. It was originally designed to be used by anyone needing protection from unauthorized eavesdropping.
DES (Data Encryption Standard) provides a higher
level of security, and also uses cipher feedback. It was originally designed to be used only by the Federal government.
DVP-XL/DES-XL - A disadvantage of the DVP and
DES encryption types is reduced communication range when compared to clear voice. The DES-XL and DVP-XL methods were designed to provide better range but at the cost of lower voice quality. They use a different type of feedback called counter addressing.
10.1.3 ENCRYPTION AVAILABLE WITH VARIOUS CHANNEL TYPES
Analog Channels
On analog conventional and SMARTNET/Smart­Zone channels, DES and DES-XL encryption is used to provide secure communication. The DES-XL type is available only with later 41xx portables equipped with the Motorola UCM (Universal Crypto Module).
Digital Channels
On digital Project 25 and SMARTNET/Smart Zone channels, the DES-OFB or AES protocol is used.
10.1.4 FIPS AND NON-FIPS MODES
FIPS 140-2 is a Federal Information Processing Standard for encrypted radios used by the Federal Government. This standard specifies Federal security
61
Zone 1, Chan 2
Zone 2, Chan 4
Zone 2, Chan 5
Zone 3, Chan 1
Zone 3, Chan 2
PID
1
2
3
4
5
SECURE COMMUNICATION (ENCRYPTION)
Crypto Group A
Keyset A1 Keyset A2
Keyset ID 1
Algorithm ID
Update Item (Opt)
Time/Date (Opt)
Keyset Name (Opt)
Key #21: Key ID 94
Key #22: Key ID 98
Key #23: Key ID 99
Key #24: Key ID 91
Key #25: Key ID 90
Storage Loc.
Number (CKR)
SLN 21
SLN 22
SLN 23
SLN 24
SLN 25
Algorithm ID
Update Item (Opt)
Time/Date (Opt)
Keyset Name (Opt)
Key #21: Key ID 54
Key #22: Key ID 65 Key #23: Key ID 67
Key #24: Key ID 69
Key #25: Key ID 73
Figure 10-1 Key Selection Example
Keyset ID 2
requirements for cryptographic modules for a wide range of applications and environments.
10.2 ENCRYPTION KEYS
10.2.1 INTRODUCTION
An encryption key is a cryptographic variable that is required by the encryption algorithm to encrypt and decrypt voice or data. T o maintain system security , these keys must be protected from disclosure and also periodically replaced or updated.
With the AES and DES encryption used by EFJohnson radios (see Section 10.1.2), the same encryption key is used by both the encrypting (sending) and decrypting (receiving) radio. AES encryption keys are generated from a string of 64 hexadecimal characters, and DES keys are generated from a string of 16 hexadecimal characters. Another four hexadecimal characters are used to specify the key ID. Multiple keys can be loaded into a radio using OTAR or manual loading.
When an encrypted message is transmitted, the encryption Algorithm ID (ALID) and key ID (KID) are usually included in the message. This tells the receiving radio which key and algorithm must be used to decrypt the message.
If an attempt is made to transmit a secure message without loading the corresponding key, “KEYFAIL” is displayed. The message must then be
transmitted in the clear mode (this is possible only if the channel is strapped to “switchable”) or the key must be loaded.
10.2.2 KEY AND ALGORITHM IDS
Each encryption key is programmed with a Key ID (also called Logical ID). This ID plus the algorithm ID (ALGID) is transmitted in the message. The radio receiving the message must have a key programmed with the same IDs in order to decrypt it.
10.2.3 PID/SLN KEY MANAGEMENT MODES
NOTE: The term “SLN” from the Project 25 specifica­tion is equivalent to “CKR” (Common Key Reference) also used to define this parameter.
The channels, talk groups, and other calls that use encryption are linked to a specific Physical ID (PID) when the radio is programmed using the PCConfigure programming software. For example, Zone 1, channel 1 could be programmed to select the key in PID 1 and Zone 1, channel 2 could select the key in PID 3. The PID ranges are 0-15 when the PID mode is selected, and 1-16 when the SLN mode is selected (see Figure 10-1).
PID or SLN key management modes can be programmed on the Global programming screen. More information on these modes follows.
PID Mode - The PID mode can be used only when keys are loaded using the Motorola KVL 3000
62
SECURE COMMUNICATION (ENCRYPTION)
keyloader. When this mode is selected, keys are loaded directly into a PID of 0-15 that corresponds to the PID programmed for each channel (if applicable). A Keys Table is not programmed with this mode.
SLN Mode - The SLN mode must be selected is either OTAR (Over-The-Air-Rekeying) or the EFJohnson System Management Assistant (PDA keyloader) is used. It can also be used if OTAR is not used. With this mode, keys are loaded into a SLN (Storage Loca­tion Number), typically from 0-4095. A Keys Table must then be programmed to link channel PIDs to a specific SLN.
The use of this type of indirect linking allows keysets and key IDs to be changed via OTAR while keeping the mapping from the channel or talk group the same. For example, as shown in Figure 10-1, PID 4 selects SLN 24 which selects key slot 24 in both keysets. This slot contains Key ID 69 in Keyset 1 and Key ID 91 in Keyset 2. Only one keyset is active at a time.
10.2.4 MAINTAINING KEYS IN MEMORY
The radio may need to be connected to a constant power source to preserve the encryption keys in memory. The programming of the Infinite Key Reten­tion parameter determines if keys are permanently stored in memory or erased soon after power is removed.
When multiple encryption keys are programmed (see preceding information), the Key Select option switch can be programmed to allow selection of another key for the current channel. This feature changes the PID (hardware location) of the key, and the change is permanent (cycling power or selecting a different channel does not reselect the original key). Therefore, to switch back to the original key, it must be manually reselected. Proceed as follows to select a key:
1. Press the Key Select switch or select that menu
parameter and HWKEY x is displayed. The “x” indicates the current key PID selection.
2. Press the Up/Down switch to display the desired key
and then press the F2 (Select) key to select it. Press the F1 (Exit) or Key Select switch again to return the display to normal operation.
10.2.6 ENCRYPTION KEY ERASE
A Key Erase menu item can be programmed that allows the user to permanently erase all stored keys. If OTAR TEK and KEK keys are stored, all keys of both types are erased. This function can be used to ensure that unauthorized encrypted calls can no longer be placed or received by a radio.
10.2.7 ENCRYPTION ICON OPERATION
When Infinite Key Retention is enabled, keys are stored in memory and are not lost when power is removed. If it is disabled, they are maintained only until the storage capacitance discharges. With 4100 models, storage capacitors maintain the supply voltage (and encryption keys) for approximately 30 seconds without power applied. Therefore, when changing the battery, make sure to reattach another within 30 seconds.
With 5300 models, the keys are maintained for approximately 8 hours with this feature disabled. However, a tamper switch causes immediate key erasure when the radio cover over the logic board is removed.
10.2.5 ENCRYPTION KEY SELECT
NOTE: This feature is available on conventional channels only.
Basically, the encryption icon is on continu­ously whenever a secure call is received or trans­mitted. Other operation is as follows:
When a secure call is received on a digital channel
in either the secure or clear mode, this icon flashes.
When a clear call is received on a digital channel in
the secure mode, this icon is on continuously.
There is a programmable option on the Radio Wide
screen to sound a beep whenever a secure call is received on a clear channel.
10.3 CLEAR/SECURE STRAPPING
10.3.1 TRANSMIT MODE OPTIONS
The following transmit options are available when encryption is selected:
63
SECURE COMMUNICATION (ENCRYPTION)
Clear - All calls are in the clear mode unless responding to a secure call. If the response is then made within the delay time (see Section 4.8.4), it occurs in the secure mode.
Secure - All calls are made in the selected secure mode.
Switched - The mode is selected by the Clear/Secure switch. When the clear mode is selected by this switch, “CLEAR” is flashed, and when the secure mode is selected, “SECURE” is flashed.
If the channel has been strapped “Clear” and the option switch selects the “Secure” mode on power up and a transmission is attempted, “Clear Only” is displayed and transmitting is disabled. Likewise, if the channel is strapped “Secure” and the option switch selects the “Clear” mode on power up and a transmis­sion is attempted, “Secure Only” is displayed and the transmitter is disabled.
The radio can be programmed to ignore the “Clear” or “Secure” switch setting (“Ignore Clear/ Secure Switch When Strapped” selected on Global screen). These preceding indications then do not occur and transmissions always occur in the strapped mode.
NOTE: If all channels/talk groups are strapped clear or secure and no Clear/Secure option switch or menu parameter is programmed, this parameter must always be selected (see following).
If the Clear/Secure switch or menu parameter are not programmed, the radio is always in the last known state (usually Clear) and there is no way to change it. For example, if the last known state is Clear and this parameter is not selected, it is never possible to transmit a Secure message on a channel strapped Secure because all that happens is transmitting is disabled, an error tone sounds, and “Sec Only” is displayed.
No Autodetect - Only signals coded like the transmit signals are received.
Secure Autodetect - Both clear and secure signals are automatically detected. This mode is automatically selected if the transmit mode is switch selectable.
Proper Key Autodetect
Analog Channels
When this feature is disabled and a message is received with the wrong key, the audio unmutes and garbled (encrypted) audio is heard. However , if this occurs with this feature enabled, the audio remains muted.
Digital Channels
When this feature is enabled and a message is received with a different key, but the key resides in the radio, the audio is decrypted and received normally even though the key is assigned to a different talk group. If this feature is disabled or the key does not reside in the radio, the audio remains muted.
10.3.3 TALK GROUP ENCRYPTION OVERRIDE
On conventional digital (P25) channels, the encryption strapping mode and PID are programmed on a per talk group basis similar to the trunked modes (SMARTNET/SmartZone/P25 Trunked). Howeve r, with this mode only, there is the option to override the talk group encryption programming and program it on a per channel basis. Therefore, if desired on conven­tional digital channels, encryption can be programmed differently for each channel. Conventional analog channel encryption is always programmed on a per channel basis.
10.4 OTAR (OVER-THE-AIR REKEYING)
10.3.2 RECEIVE MODE OPTIONS
The following receive options can be programmed with conventional operation. With SMARTNET/SmartZone and P25 Trunked operation, encrypted calls are received if the proper key is programmed.
10.4.1 INTRODUCTION
OTAR stands for “Over-The Air-Rekeying”. This is the process of sending encryption keys and related key management messages over-the-air to specific radios. The advantage of OTAR is that it allows these keys to be quickly and conveniently updated when
64
SECURE COMMUNICATION (ENCRYPTION)
necessary. It is no longer necessary to periodically travel to the radio location or bring the radio into a maintenance facility to load new keys.
The actual OTAR rekeying functions are performed by a Key Management Facility (KMF) that sends Key Management Messages (KMM) to the radios. These messages are themselves encrypted using a unique key . Rad ios must be OTAR-compatible and programmed for OT AR for this type of rekeying to occur.
Currently, OTAR is available only on P25 conventional channels, and to program DES-OFB and AES keys (future programming on P25 trunked chan­nels is planned). It is not used on SMARTNET/Smart­Zone channels or to load DES/DES-XL keys.
10.4.2 ENCRYPTION KEY TYPES
There are two types of keys used with OTAR:
TEK (Traffic Encryption Key) - The key used to encrypt voice and data traffic. All radios using encryp­tion must have at least one of these keys. This is also another name for the keys used without OTAR.
KEK (Key Encryption Key) - The key used to encrypt keys contained in OTAR Key Management Messages (KMMs). All radios which use OTAR must contain at least one of these keys. The KEK used to decrypt/encrypt keys in an OTAR message is defined by the algorithm and key IDs transmitted in the decryption instructions field. A KEK may be unique to a particular radio (UKEK) or common to a group of radios (CKEK).
10.4.3 KEYSETS
To simplify key management, a number of keys may be grouped together in a keyset. A keyset is simply a set of one or more keys of the same type (either TEK or KEK). Keysets are identified by Keyset IDs, and the upper four bits of this ID specify the crypto group (see next section).
The KEK keyset is considered always active and is ID 255. Two TEK keysets are normally used, and one is always active and the other inactive. This allows the inactive keyset to be replaced without interrupting operation. One is Keyset ID 1 and the other Keyset ID
2. With EFJohnson radios, each keyset can contain up to 128 keys, but less than 16 are normally used for optimum keying efficiency and because only up to 16 can be selected by the radio.
The active keyset is usually selected by the Key Management Facility. It can also be selected by the keyloader function of the EFJohnson SMA (Subscriber Management Assistant) or by the user if the Change Keyset option switch or menu parameter is programmed. Automatic keyset changeovers are not supported by EFJohnson radios. In the SLN mode (see Section 10.2.3), two TEK keysets can be used if desired even if OTAR is not used.
A diagram of a keyset is shown in Figure 10-2. Some information may be optional as shown. The 41xx portable does not support or use the Update Item and Time/Date parameters.
16-Bit Keyset ID
Algorithm ID
Update Item (Opt)
Time/Date (Opt)
Keyset Name (Opt)
Key 1 Key 2
Key 4096
(upper 4 bits are Crypto Group)
Figure 10-2 Keyset Diagram
10.4.4 CRYPTO GROUPS
A crypto group contains up to 16 keysets of the same type of key, either TEK or KEK (see Section
10.4.2). However, only two keysets are typically used as just described. Crypto groups are used to help manage keys such as when a radio uses keys with different active times or multiple algorithms. Currently , only one crypto group is supported, and it is always ID 0. As shown in Figure 10-3, the crypto group ID is the upper four bits of both the SLN and Keyset IDs.
10.4.5 KEY MANAGEMENT FACILITY
The Key Management Facility (KMF) provides key management and OTAR functions to applicable
65
SECURE COMMUNICATION (ENCRYPTION)
radios within the radio system. One of the main tasks of the KMF is to maintain a data base of information
Crypto Group ID
(4-Bit = 0-15/0-F)
xxxx
xxxx xxxxxxxxxxxx
SLN/CKR ID
16-Bit = 0-65535/0-FFFF
Figure 10-3 Encryption Parameter IDs
contained in each radio. This information may include the following:
xxxx xxxx
Keyset ID
8-Bit = 0-255/0-FF
TEKs (main Traffic Encryption Keys)
KEKs (Key Encryption Keys) used to encrypt
OTAR messages
Keysets (groups of TEKs or KEKs)
Crypto groups (groups of keysets)
Cryptonets (groups of radios using same keys)
Individual and group Radio Set Identifiers (RSIs)
List of probable lost or stolen radios
The KMF performs OTAR functions by exchanging Key Management Messages (KMMs) with the radios. Both the KMF and radio can originate messages. Some functions performed by the KMF are as follows:
Loading new keys
Modifying keys
Initiating keyset switch overs
Modifying keyset attributes
Deleting one or more keys to remove a radio from a
cryptonet)
Deleting all keys (zeroize) when a radio may be lost
or compromised
Determining if a radio is on the air and reading key
information
Changing individual and group RSIs
10.4.6 MESSAGE NUMBER PERIOD (MNP)
One of the parameters that is programmed in a radio utilizing OTAR is Message Number Period (MNP). This parameter is programmed as described in
Section 10.5.2. This parameter is used to minimize the possibility of someone sending messages to “spoof” the system. The MNP is used as follows.
Every message sent out has a message number. The message number increments by one with each message sent. The MNP is the maximum difference allowed between messages. For example, if the MNP is set to 1000 and the last message number received by the radio is different by more than 1000 from the current message number, the current message is ignored. If the MNP is set to 65535, message numbers are ignored.
When determining this number, consider the like­lihood of someone trying to spoof the system by retransmitting recorded messages and then adjust the MNP accordingly. The higher the risk, the smaller the MNP should be. A disadvantage of setting a low MNP is that the chance of blocking out intended messages becomes higher. In addition, traffic level and terrain contribute to lost messages and should also be consid­ered when selecting this number.
A setting of 1000 is a good compromise because it blocks out real old messages but is unlikely to affect anything intentionally sent out by the system (1000 messages sent to a single radio is not likely to occur in a system in less than a year with normal usage).
10.4.7 DEFINITIONS
Algorithm - Refers to the specific encryption standard (DES or AES) that is used to encrypt a message. Each standard uses different calculations to perform the encryption (see Section 10.1.2).
Algorithm ID (ALGID) - Identifies the algorithm (DES or AES) used to encrypt a message. This ID and the Key ID are transmitted with each message to uniquely identify the key being used.
Black - Refers to information that is encrypted. The opposite is “Red” which refers to unencrypted infor­mation.
Common Key Encryption Key (CKEK) - This is a KEK common to a group of subscriber units which share the same encryption keys (are part of same crypto group). These keys can be the DES or AES
66
SECURE COMMUNICATION (ENCRYPTION)
type. The use of a common key allows the subscriber units to be rekeyed by the KMF using one Key Management Message. Refer to “KEK” for more information.
Common Key Reference (CKR) Group - Same as Storage Location Number (SLN).
Crypto Group - A group of up to 16 keysets containing the same type of keys (either TEK or KEK). Although a crypto group can contain up to 16 keysets, only two are normally used. Only one keyset in a crypto group is active at a time. EFJohnson radios currently support only one crypto group.
Cryptographic Variable - The variable used by a cryptographic algorithm to encrypt a message. Also called a “key”.
Currency - Relates to the need for key updates. If a subscriber unit is current, it does not require a key update at the current time. If it is not current, the KMF has new keys for that subscriber unit or CKR group have not been sent or have been sent but not acknowl­edged.
Key ID - This is a 16-bit (four hex digit) number iden­tifier from 1-65535 for an encryption key which allows the key to be identified without revealing the actual key variable. This ID and the Algorithm ID uniquely identify a key within the KMF or subscriber unit. Therefore, two keys can have the same ID if they have different algorithm IDs and vice versa. The Key ID and Algorithm ID are usually transmitted with a message to identify the key that must be used to decrypt it. Key ID 0 is not used with OTAR.
Key Management Facility (KMF) - The equipment and software which provide OTAR and related key management services to the subscriber units.
Key Management Message (KMM) - These are the messages composed by the KMF to send encryption information to subscriber units via the keyloader or OTAR. KMMs are themselves encrypted using two layers of encryption: inner and outer. The inner layer of encryption is the KEK and the outer layer is the TEK. At this layer, the KMMs are also included in a Common Air Interface (CAI) message which adds another layer of addressing. In addition, a Message Authentication Code (MAC) is used.
Group Rekeying - The process of changing the keys in several subscriber units with a single message addressed to the group rather than changing each subscriber unit separately. This addressing is done using a group RSI. Group rekeying reduces system overhead and makes rekeying more efficient. Subscriber units in the same group must be programmed with a common KEK (CKEK) and use the same TEKs.
Key - A variable used by a cryptographic algorithm to encrypt voice or data. Also called “Cryptographic Variable”.
Key Encryption Key (KEK) - A key used to encrypt keys contained in Key Management Messages (KMMs) during OTAR. These messages may them­selves be encrypted by the currently active TEK. These keys can be the AES or DES type. There are KEKs unique to a subscriber unit (UKEK) and common to a group (CKEK). The other type of key is the Traffic Encryption Key (TEK) used to encrypt voice and data messages.
Keyset - A group of keys of the same type (KEK or TEK) that are managed as a single entity (they can be updated, deleted, and rekeyed with a single command).
Keyset Changeover - The process used to switch a subscriber unit to another keyset so that the unused keyset can be replaced without interrupting encrypted communication.
Key Loader - Any type of device used to load encryp­tion keys into a radio. With OTAR, this device must be used to provide the initial key loading of a subscriber unit so that it contains the basic keys needed for OTAR by the KMF. If OTAR is not utilized, is always used to load encryption keys. All keys stored in the key loader are themselves encrypted. EFJohnson offers a PDA-based keyloader.
Logical Link ID (LLID) - An ID transmitted with a data message to identify the destination of the message.
67
SECURE COMMUNICATION (ENCRYPTION)
Message Number Period (MNP) - The maximum difference between message numbers that can occur before a message is declared invalid (see Section
10.4.6).
Over-The-Air-Rekeying (OTAR) - The process of sending new encryption keys over the air using an RF interface.
Red - Refers to information that is not encrypted. The opposite is “Black”.
Rekey - The process of preparing, sending, and loading encryption keys into a subscriber unit for current or future use. This may be done over-the-air (OTAR) or by directly connecting a keyloader to the subscriber unit.
Radio Set Identifier (RSI) - Subscriber units are programmed with one or more Radio Set Identifier (RSI) numbers that identify the unit for OTAR purposes. The RSI can be unique to a individual subscriber unit or unique to a group of subscriber units. An individual (unit) RSI is always assigned and one or more group RSIs may be assigned. The indi­vidual RSI is typically programmed when the subscriber unit is initially brought into service. The KMF is also identified by an RSI (KMFRSI) to use as the destination of any KMMs a subscriber unit origi­nates. The KMMs (Key Management Messages) generated by the KMF (Key Management Facility) are addressed to a specific RSI.
Storage Location Number (SLN) - A link to a specific key (TEK or KEK) in the active keyset. The SLN specifies both a crypto group and a key within the keysets in that crypto group (the first four bits of the SLN are the crypto group ID). SLNs and CKRs are equivalent terms (see Section 10.2).
Traffic Encryption Key (TEK) - A key used to encrypt voice or data. The other type of key is the Key Encryption Key (KEK) which is used to encrypt keys contained in Key Management Messages. TEKs can be either the AES or DES type.
Unique Key Encryption Key (UKEK) - A KEK unique to a particular subscriber unit. Refer to “KEK” for more information. These keys can be either the AES or DES type.
Zeroize - The process of deleting all keys from a compromised subscriber unit to disable it. T o make the unit functional again, the keys must be reloaded by a keyloader.
10.5 RADIO SETUP FOR ENCRYPTION
10.5.1 GENERAL ENCRYPTION SETUP
The following radio setup is required for encryp­tion regardless of whether OTAR is used:
Options Enabled - The desired encryption type must have been enabled at the factory (DES, DES-XL, DES-OFB, AES). To determine what options are enabled, using the PCConfigure programming soft­ware, select the Transfer > Read Options From Radio menu parameter.
PCConfigure Programming
PID/SLN Mode
- On the global screen, select either the PID or SLN mode (see Section 10.2.3). If the SLN mode is used, also program the Keys Table by clicking the button.
Infinite Key Retention
- On the global screen, select this parameter to store keys permanently in memory (see Section 10.2.4).
Erase Keys On Keyset Change
- On the global screen, if the SLN mode is selected and more than one keyset is used (see Section 10.4.3), select this parameter to erase keys when changing keysets (see Section 10.2.6).
Program Channel/Group PIDs and Encryption
Type - With conventional analog calls, this infor­mation is programmed on the channel screen. With other types, it is programmed in the talk group list selected on the system screen. In addi­tion, with conventional digital calls, the group programming can be overridden on the channel screen (see Section 10.3.3). Additional PIDs for special calls can also be specified on the system screen for digital and trunked calls. NOTE: The
encryption type is not selectable on digital chan­nels because the AES/DES mode is determined by the key type loaded, not by PCConfigure programming.
68
SECURE COMMUNICATION (ENCRYPTION)
Currently, EFJohnson 41xx portables and 43xx mobiles that meet the following requirements support OTAR:
Programming - An RSI and UKEK and other infor­mation must be programmed as described in the next section.
10.5.2 ADDITIONAL SETUP FOR OTAR
Additional PCConfigure Programming For OTAR
The following parameters must be programmed for OTAR operation in addition to those in Section
10.5.1 .
1. On the Radio Wide Conventional screen, program
the Digital Unit and Unit RSI IDs. The Unit RSI ID can be set to the Digital Unit ID only, but later can be changed by the KMF or keyloader if desired. Note these two numbers.
2. On the Per System Conventional screen, select
OTAR Enabled = On and Data Registration Enabled = On. When data registration is enabled,
the radio registers with the data system on a channel change.
3. Also on the Per System Conventional screen, set the
OTAR Time Out Time. When rekeying is requested by the radio (OTAR Rekey option button pressed or menu selected), this setting determines how long the radio waits for a response from the KMF . Times of 20-180 seconds can be programmed, and the default is 30 seconds.
Motorola RNC Registration (If Required)
Programming By Keyloader
The following are the minimum parame ters that need to be programmed in the radio to perform OTAR. It is not necessary to program a TEK to perform OTAR. If the radio does not contain a TEK, the KMF initiates a warm start-up sequence in which a tempo­rary TEK is transferred to the radio to perform the key transfer.
1. UKEK - This key normally has SLN (CKR) 61440
and Key ID 62880 (F5A0 hex). Create a key (either AES or DES type as required) and download it to the radio.
2. RSI - This is normally initially the same as the P25
Unit ID and is programmed by the PCConfigure software as described in Section 10.5.1. Therefore, the RSI should not need to be loaded if it is the first time the radio is being set up for OTAR or if the radio dumps keys due to long-term battery discon­nect. However, it may need to be loaded if the radio is manually deleted from the KMF and then recre­ated since the message number must be reset to 0 (the Load Target RSI command resets the message number to 0).
3. KMF RSI - This RSI is normally 9,999,999 and
should not need to be loaded since it defaults to this number.
4. MNP (Message Number Period) - Load the proper
message number period into the radio (typically
1000). Refer to Section 10.4.6 for more information.
5. Verify that the above information was properly
stored in the radio by viewing it using the keyloader .
The 41xx portable does not support Motorola dynamic data registration. Therefore, each radio must be manually registered on the Motorola RNC Console by entering the following command:
LCRD 03 06 00 1234 7F xx xx xx 0A 0A 00 07 00 yy
Where, “xx xx xx” is the hex value of the Digital Unit ID entered by the PCConfigure software. Refer to the console documentation for the value of “yy” or use “00”. This registration needs to be done only once.
10.6 RADIO OTAR CAPABILITIES
10.6.1 SEM 4100/53XX, STANDARD 41XX
The OTAR capabilities of the SEM equipped
4100 portable and 4300 mobile are as follows.
Keysets
Up to three keysets are used and it is assumed all
three are always present.Keyset IDs 1 and 2 are for
69
SECURE COMMUNICATION (ENCRYPTION)
TEKs and only one is active at a time. Keyset ID 255 is for KEKs and is considered active all the time
Each keyset can have up to 128 keys. However, 16
or less are normally used.
AES encryption is supported (with Flash code 1.8.0
or later) but not currently available with OTAR (future availability is planned).
RSI (Radio Set Identifier)
One individual RSI and it is usually initially the
same as the P25 Unit ID.
One group RSI (usually initially “0”).
One KMF RSI (usually always 9,999,999).
OTAR Messages That Are Supported
The following KMM Message IDs are recognized by or sent:
CHANGE RSI 0x03 CHANGE RSI RESPONSE 0x04 KEYSET CHANGEOVER 0x05 KEYSET CHANGEOVER RESPONSE 0x06 DELAYED AC K 0x07 HELLO 0x0C INVENTORY 0x0D INVENTORY RESPONSE 0x0E MODIFY KEY 0x13 MODIFY KEYSET ATTRIBUTES 0x14 MODIFY KEYSET ATTRIBUTES RESPONSE0x15 NEGATIVE ACK 0x16 NO SERVICE 0x17 REKEY ACK 0x1D REKEY 0x1E WARM START 0x20 ZEROIZE 0x21 ZEROIZE RESPONSE 0x22
10.6.2 UCM EQUIPPED 4100
same as described in Section 10.5.
10.6.3 OTAR OPTION SWITCHES
The following additional option switches can be programmed with the 4100 portable and 4300 mobile to control OTAR functions. They are also available as 4100 menu parameters unless noted otherwise.
Change Keyset - Toggles the active keyset between Keyset 1 and Keyset 2. The new active keyset is briefly displayed and then normal operation resumes. When the 4100 menu is used, the current active keyset is indicated by an asterisk. To change to the other keyset, highlight it and press the F2 key.
Clear/Secure Select - This enables and disables encryption regardless of whether OTAR is used. Refer to Section 10.3 for more information.
Erase Keys - Erases all TEK and KEK keys contained in the radio. With the 4100, this function is available as menu parameter only.
Key Select - This allows a different key to be selected for the current channel or group (conventional chan­nels only). Refer to Section 10.2.5 for more information.
OTAR Rekey Request - Sends a message which tells the KMF that the radio is on the air and requests rekeying. The following status messages are displayed which indicate the progress of this function. Addi­tional functions that are available when this is selected using the 4100 menu mode are described in the next section.
Rekeying process.
No Ack in response to an Identify request before time out occurred (approximately 30 seconds).
- A radio-initiated rekeying session is in
- No response was received from the KMF
The 41xx UCM version uses the Motorola UCM encryption module. Therefore, the OTAR capabilities are determined by that module. All capabilities of the Motorola KVL and KMF are supported. Initial radio programming by the PCConfigure software is the
70
Ack Rcvd response to an Identify request.
No Service from the KMF. No rekeying will take place.
- An acknowledgement was received in
- A “No Service” reply was received
SECURE COMMUNICATION (ENCRYPTION)
Rekey Fail - Either the rekey command failed or timed out (after approximately 30 seconds). This message could indicate that the rekey request message was not received by the KMF. However, depending on the KMF configuration and channel traffic, it is possible that the message was received and a response is still pending.
Rekeyed!
- The rekey session initiated by the radio
was successful.
Additional Functions Selectable by 4100 Menu:
(To select one a parameter, highlight it and press F2.)
Rekey
- Performs the same function as the OTAR Rekey Request option switch described in the preceding section.
Need KEK
- Sends a request for a new KEK (Key Encryption Key). Upon receiving this message, the KMF marks the radio as requiring service. One time this function may be selected is if the radio dumps it keys.
Identify
- Sends a message which tells the KMF that the radio is on the air. Currently, the KMF always responds with “No Service”, even if the keys are not up to date. If “No Ack” is displayed, the KMF may not have received the message (see preceding section). This function can be used to test communi­cation without initiating the rekeying that occurs with the preceding “Rekey” function.
Erase Keys
- Erases all keys in the radio the same as the Erase Keys option switch described in the preceding section.
71
INDEX
INDEX
A
Accessory Connector 12 AES Encryption 61 Alert Tones 22 Algorithm 66 Algorithm ID 66 Analog and Digital Operation 42 ANI Signaling 33 Antenna Connector 11 Autodetect 64
B
Backlight 16 Battery 12 Battery Charging 16 Battery Saver Feature 16 Black 66 Busy Indicator 27 Busy Override 50
C
Call Alert 46 Call Alert (P25 Conv) 37 Call Guard Squelch 28 Channel Select 14 Channel Switch 11 Channels 18 CKEK 66 CKR 67 Clear/Secure Strapping 63 Clone Feature 34 Conventional Mode 17 Conversation Timer 29 Crypto Graphic Variable 67 Crypto Group 65, 67 CTCSS/DCS Signaling 28 Currency 67
D
Delay, Scan Resume 23 DES-OFB 61 DES-XL 61 Determining Available Options 57 Direct Channel Selection 14 Display 12 DTMF Keypad 11 Dynamic Regrouping 50
E
Emergency Alarms (Conv) 30 Emergency Alarms (SN/SZ) 48 Emergency Calls 48 Emergency Calls (Conv) 31
Emergency Hot Mic 31, 48 Emergency Man-DOwn Feature 49 Encryption 61 Encryption Key 62 Encryption Key Select 63 Encryption Keys 62 Enhanced Private Conversation
43
Mode
Extended Range Operation 56
F
F1 Key 10 F2 Key 10 F3, F4 10 Facility 65 Failsoft Operation 49 Features
Conventional General 8 P25 Trunked 9 Project 25 35 Project 25 Trunked 9, 42 SMARTNET/SmartZone 8
SmartZone 50 FIPS 140-2 61 Frequency Display 30 Front Display 10
8
G
Group Calls 42
P25 35 Group ID Code 35 Group Rekeying 67
H
Home Zone Select 22 Hot Mic 31, 48
I
Indicator
Priority Channel
Top Panel 11 Individual Calls 35 Infinite Key Retention 16, 63
32
K
KEK 67 Key 67 Key Encryption Key 65 Key Erase Menu Parameter 63 Key ID 62, 67 Key Loader 67 Key Management Facility 65
Keypad Lock 16
Permanent 16
Keypad Programming 38 Keyset 65, 67 KMF 67 KMM 67
L
Licensing 56 Lookback Time 32 Lost Passwords 59 Low Battery Indicator 15
M
Man-DOwn Feature 31 Master Radio 34 Menu Mode 20 Menu Mode Functions 21 Message Number Period 68 Message Number Period (MNP) 66 Messaging 47 Messaging (Conv P25) 38 Microphone 10 Mode
Conventional Project 25 Conv 17 Project 25 Trunked 18
SMARTNET/SmartZone 17 Monitor Mode 27 Monitoring Before Transmitting 27
17
N
NAC 35 Network Acess Code 35 Nuisance Channel Delete 24
O
On-Off/Volume Control 11 Operating Modes 17 Option Button
Key Select Option Switch 11
Alert Tones 22
Backlight 16
Call Alert 37, 47
Call Response 45
Change Keyset 70
Channel Select 14, 15
Clear/Secure 42, 70
Digital Talk Group Select 35
Display Information 30
Emergency 11, 30, 31, 48
Erase Keys 70
63
74
INDEX
High/Low Power 22 Home 22 Key Select 63, 70 Keypad Lock 16 Keypad Programming 39 Message 38, 47 Monitor Mode 27 Normal/Selective 28 OTAR Rekey Request 70 P25 Packet Data 38 Phone 37, 45 Priority Select 33 Private Call 43, 44, 45 Private Call (SmartNet) 43, 44, 46 Radio Wide Scan 23 Repeater Talk-Around 30 RWS List Edit 26 Scan 23 Scan List Edit 25 Scan List Select 25 Selective Squelch 29 Set User Password 14, 59 Single Tone Encoder 33 Site Lock 51 Site Search 51 Squelch Select List 29 Status 38, 47 Surveillance Mode 22 Talk Group Select 35 To ne Volume 22 Unit Call 36, 37
Volume Up/Down 13 Option Switch Functions 21 Option Switches 20 Option Upgrading 57 Optional Features 57 OTAR 68 OTAR Definitions 64 OTAR Messages Supported 70
P
P25 Packet Data 38 Paging 37, 46
Answering 46
Answering (Conv P25) 37
Initiating 37, 47 Password
Changing
Download/Upload 59, 60
Master 59, 60
Operation 59
Power On 59, 60
Power-Up 13
User 59, 60
Zone 60 Penalty Timer 29 PID Mode 62 Power On-Off 13 Power Output Select 22
59
Power Up Sequence 13 Power-Up Password 13 Priority Channel
Changing
Priority Sampling
Conv P25 Trunked 49
SMARTNET/SmartZone 49 Programming 55 Project 25
Group ID Code
Unit Calls 35
Unit ID 35 Project 25 Mode 18, 35 PTT ID 43 PTT Switch 11
33
32
35
R
Radio Options Screen 58 Radio Set Identifier 68 Radio Wide Mode Scan List 26 Radio Wide Scan 23 Receive Only 17 Red 68 Rekey 68 Repeater Talk-Around 30 RS-232 Port 38 RSI 68 RW Scan List
Determining Channels in
Editing 26
26
S
Scan Hold Time 23 Scan List 24
Channel Delete 24
Determining Channels in 24
Editing 25
Selecting 25 Scanning 23
Conv 31
P25 Trunked 49
Priority 23
Radio Wide 23
SMARTNET/SmartZone 49 Secure Communication 61 SecureNet 61 Servicing 56 Silent Mode 30 Single Tone Encoder 33 Site ID (SmartZone) 51 Site Locking/Unlocking 51 Site Trunking 50 Slave Radio 34 SLN Mode 62 SMARTNET/SmartZone Mode 17 Soft Power Down 13 Speaker 11 Speaking Into Microphone 56
Squelch Adjust 17 Squelch Code Select 29 Squelch Control 17 Standard Calls
Placing (Conv) Receiving (Conv) 33 Receiving (SMARTNET) 42
Standard Private Conversation
Mode
Status Messages 38, 47 Storage Location Number 68 Supervisory Tones 53 Surveillance Mode 22 Systems 18
33
43
T
TEK 68 T elephone Calls 45 T elephone Calls) 36, 45 TG on Rx 43 Tim e-Out Timer 20 Tone Select 22 Tones 53 Trademark Information 2 Traffic Encryption Key 65, 68 Transmit Disable 17 Transmit Disable On Busy 27 Transmit Type 41 Transmitting in Scan Mode 24, 32 Troubleshooting 56
U
Unit Calls
35
P25
Unit ID
Project 25 Conv
SMARTNET/SmartZone 42 Unit-To-Unit Calls 43 Up/Down Switch 10 User Group ID 43
35
V
Voice Encryption 61 Volume Adjust 13 Volume Control Disable 13 Volume Up/Down 13
W
Warranty 2 Wirel ess Cloning 34
Z
Zeroize 68 Zone Password 39, 60 Zone Select 11, 14 Zones 19
75
Part Number 002-4100-xxx x
12-04 Printed in U.S.A.
Loading...