Contents 2
Warranty 3
General 4
To the installer 5
Parts of the system 6
Parts of the system 7
The system 8
The components 9
The Laddomat valve 10
Connections in the tank 11
The control panel 12
Electrical installation 13
Environment 14
The rst re 15
Soot removal 16
Annual service 16
Troubleshooting 17
CE Mark 18
Innehållsförteckning
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
Effecta Products are guaranteed to be free of defects in materials and workmanship for two years from the installation date. This applies to wear parts, such as seal, the main body of the boiler, cera­mics and electrical components. This guarantee also covers original spare parts. Any faulty products will be replaced or repaired at the discrimination of the retailer or Effecta. If a faulty product is replaced, Effecta is entitled to replace it with a new or reconditioned product of the same or a simi­lar type. Effecta gives a 5 year warranty on the remaining components. See the attached warranty document.
If you have a complaint, you must contact Effecta before starting any servicing work. You must submit your complaint without delay. You must always state the type of product, the date of purchase and the serial number.
Otherwise the heating and plumbing industry´s current regulations apply in the case of complaints. Guarantee terms:
The guarantee is valid on condition that:
The boiler and the heating system have been installed in accordance with the installation instructions and in a professional manner.
The location where the product is installed is suitable for the purpose.
The pellet burner used is recommended by Effecta.
The guarantee does not cover:
The overall functioning of the heating system, costs incurred as a result of the heating system being out of operation or the cost of the temporary replacement of products.
Damage or injury caused by negligence during the installation or by operating the boiler in a
way which conicts with the installation and user instructions.
Damage caused by abnormal wear, incorrect operation and maintenance.
Damage caused by the boiler being positioned in an unsuitable location.
Damage caused by vermin.
Date
Installer
Electrician
Warranty
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
In General
Effecta Lambda is a woodred boiler with a suction fan. The boiler should be connected to one or
more accumulators, which are heated via a Laddomat valve. Warm water is taken from the top of the boiler and is fed to the top of the tank. The return water is taken from the bottom of the tank and is fed to the bottom of the boiler.
Domestic water
To get domestic water, the tank needs to be equiped with a coil.The tenperature of the water is regu­lated with a mixing valve.The amount of warmwater is dependent upon the temperature and size of the tank.
Combustion
On the front of the boiler is two airinlets with dampers, which are controlled by two motors. The mo­tors gets signals from the lambdacontrol depending on the amount of oxygen in the uegases. The sys­tem is designed to get as low output of harmful gases as possible. Normally you don´t need to change the settings when you are burning different kinds of wood with different moisture content.
The system
Effecta Lambda should be connected to at least 1500l of accumulation volume. At installation, there
should always be a Laddomat valve connected.A woodred boiler that is connected to one or more
buffertanks will have a lot of advantages:
• The grate can always be fully loaded
• The user will have a long time between the warmups
• Prolonged lifespan
• The boiler is always used on maximum prestanda
• Efcency and envirinmental assets will be on top
You should always strive after a dimension of the accumulationsystem, so that you don´t need to make
more than one warmup a day.When you startup a new re,the fan will start to provide combustion air and to prevent smoke from coming out of the reside. When the boiler has reached a temperature of 78degrees, the charging of the tank starts. The laddomat valve care for the statication in the tanks.
When the accumulators are heated, the pump and fan stops. The warm water in the tanks then heats the radiators in the house, and the domestic water through a coil.
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
To the installer
It´s now time for the installation of the boiler. Try to follow the examples we are describing for a safe installation. After the installation, be careful to educate the end user of the boiler how the system is used and maintained, this is to avoid unnecessary stops an problems.
Location
The boiler shall be placed on a rm foundation, try also to place the boiler as horizontally as possible,
this to avoid airpockets in the boiler. Keep in mind the laws and regulations regarding distances to com­bustible materials.
The boiler room
The boiler room shall be constructed according to current laws and regulation, if uncertain regarding this, contact concerned authority. You need good ventilation in the boiler room to get the best performance of the Woody Lambda.
The accumulator
It´s important that the accumulators are well isolated, this is to get as small heatlosses as possible. To get a good comfort regarding the number of times you have to be in boiler room, you need at least 1500l of accumulation volume.
The chimney
The chimney should have a diameter of at least 150mm,if you have a chimney with less diameter, Effecta should be consulted before installation. The draft in the chimney should at low temperature be approx 15 pa. It´s important that the chimney is tested and approved by concerned authority before a new boiler
is installed. If the draft is to hefty a draft stabilator might be needed. If you have a tall chimney and a ue
gas temperature below 170degrees there is a risk of condensation, which in the long run can be harmful to the chimney. Adequate temperature 1 metre from the vent of the chimney is 70-80degrees.
If the chimney is tall and wide it may result in to much draft which can lead to too much gasication and too much re in the grate. This can be prevented by installing a draft stabiliser.
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
Laddomat 21
A Laddomat valve should always be mounted between boiler and tank. It´s described further on page 10.
Automatic Shunt
It´s recomended to use an automatic shunt valve to control the ue
in the radiator circuit. It feels the temperature in a special place in
the house and regulates the temperature in the radiator circuit ue. Using an automatic shunt will signicantly reduce the amount of
wood needed during a year, and your indoor climate comfort will also improve.
Expansion Vessel
The expansion vessel normally is tested for 6bars. Highest working temperature is 99degreees. The vessel has a preepressure of 2,5bar. The volume should be approx. 10% of the total volume of the sys­tem. An open vessel should have a volume of 5% of the total.
Safety Valve
The safety valve will release when pressure exseeds 1,5bars. When it opens water will drip out of it and the pressure goes down. Remem­ber that the system is designed for a maximum pressure of 1,5bars, and shall under no circumstanes be under higher pressure.
Shuntvalve
The shunt valve is mounted on the radiator circuit, and it´s designed to mix the accumulatorwater and the return water from the radiator to get the right temperature indoor. If mounting an automatic shunt valve, read it´s instructions.
Components
Effecta AB - Västra Rågdalsvägen 21 - 434 96 Kungsbacka - 0300 - 22320 - info@effecta.se
Valve Combination
The valve combination is mounted on the domestic water circuit. It´s purpose is to mix the hot water with cold before it reaches the water taps. This is to avoid burns, and to keep the taps and seals from be­ing destroyed by to hot water.
Piping
Normally copper is used for installing these systems. Piping between boiler and accumulators should not be less 28mm. If the piping is
longer than 6 meters to the rst tank it´s recomended to use 35mm.
The Accumulator Tank
Effecta Lambda must always be connected to some sort of accumu­lator tank, where the energy is stored, and where the domestic water and the warm water to the radiators is taken. The accumulator is described more thorough on page 13.
The Draft Stabiliser
If you have a tall and wide chimney, it´s possible that you have to install a draft stabiliser. You might notice that you have an irregular
combustion, pufng sounds from the boiler. This happens when the
chimney sucks too much air through the boiler. The placement of the draft stabiliser in the chimney should be approx. one meter above the connection to the boiler. This is because you have an overpres­sure from the fan, and if you place the draft stabiliser too close to the boiler you might have smoke coming out of the stabiliser.
OBS !
Tänk på att alltid isolera
rörledningar i systemet.