Drawings frame network / server ................................ page 16
Drawings frame 47U 800x1200 mm ........................... page 17
Drawings roof W=800 mm .............................................page 18
Drawings roof W=600 mm .............................................page 19
Drawings bottom W=800 mm ...................................... page 20
Drawings bottom W=600 mm ...................................... page 21
Page 1/21
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network-/Server Cabinets PRO
Comfortable Dismountable - Max. Load 1360 kg - Included Earthing Bar - Highest Flexibility
Page 2/21
Network- / distrbution cabinet with
rear sided cable entry
Open rack variants for individual,
modular assembly available
Common Specications
• 19“ Network-/server cabinet according to DIN41494
• Inside front and rear 4 x 19“ rails (2 front-, 2 rear-sided), galvanised, step-less depth-adjustable
• Contrariwise numbering of rack units at the 19“ proles
• Front door with window of certied safety glass (thickness 5 mm)
• Front door with 3-point bar-locking (up to 24U: 1-point latch) with turning handle, lockable, incl. prole half-cylinder acc. to DIN18252 / EN 1303
• Prole half-cylinder exchangeable by customer (30/10 mm)
• Rear door steel, 1-part, shortended, with 2 x latch locking (lock equal to door lock), 3U panel for cable entry below (cutout 690 x 67 mm)
• Door stop for front and rear door left- and right-sided possible
• Detachable side walls with 2 x latch locking (lock equal to door lock). For depth 1200 mm: 2 side walls per side (2 x 600 mm type)
• Cabinet stackable side-by-side with and without removal of side walls with screw set M6 (Art.-No. PRO-ANR01), additional clamp set (Art.-No.
PRO-ANR02) suitable for additionally stabilising of the cabinet poles (use without side walls resp. with side walls with holes)
• Roof and bottom with uo to 6 pre-punched openings for cable entry (450 x 90 mm), for 600 x 600 mm cable entry only rear-sided
(see drawings at pages 18..21)
• Roof prepared for use of 4 x transport eyes M12
• All cabinet parts inside completely grounded
• Pre-assembled earthing bar rear-downside in the cabinet (for 600 x 600 mm: left-downside)
• Max. load 1000 kg (depths 600 / 800 mm) resp. 1360 kg (depths 1000 / 1200 mm for >24U)
• Paint nish RAL7035, light grey / RAL9005, jet black
• Protection degree IP20
• Included in delivery: 1 x brush, earthing set incl. earthing cables, 4 x leveling feet M12, 2 x key
• Delivery in transport packaging on disposable pallet
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network / Server Cabinets PRO - Highlights
Page 3/21
Easy & fast dismountable:
only 4 screws each for roof and bottom
Depth rails:
• step-less depth-adjustable
• positionable in any height &
number
Roof prepared for use of transport eyes M12
Door opening angle 180° due
to external hingens
Door stop changeable l/r
Standard rear door (steel)
with 3U cable entry
Pre-assembled earthing bar
included in cabinet (connections: 20 + 2)
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
Modular plinth system
(see page 14)
3-point bar-locking
for all door types > 24U
(prole half-cylinder exchangeable)
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network-/Server Cabinets PRO - Details Cabinet Roof and Bottom
Page 4/21
Centrally located and pre-punched opening
for accommodation of fan units 380 x 380 mm.
Fan units are available as 2-fan and 4-fan variants.
The thermostat is already mounted in the fan housing.
PRO-LFD02AT.GRPRO-LFD04AT.GR
Cabinet roof in variant 800 x 800 mm with 4 surrounding,
pre-punched cable entries (450 x 90 mm).
On demand these are coverable with dummy plates 19“ 2U.
(Depth 1200 mm: 6 surrounding cable entries, see drawings)
Pre-punched opening for lters / cable entries 380 x 380 mm.
Diverse modules for ltering or cable entry are available.
PRO-MOD01.GR
(Modul closed)
PRO-MOD04.GR
(Modul with brush entry)
All cabinet parts are internally grounded.
All earthing cables for doors and side wall are pre-assembled.
PRO-MOD02.GR
(Modul with perforation)
PRO-MOD03.GR
(Modul with lter mat)
PRO-MOD05.GR
(Modul with foam entry)
Cabinet bottom in 800 x 800 mm variant. Each PRO series cabinet
is delivered with a pre-assembled earthing bar.
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network-/Server Cabinets PRO - Line-Up / Baying / Stacking of Cabinets
Page 5/21
In principle, PRO Cabinets are screwable one-to- another on the frame
with the line-up set PRO-ANR01. One set consists of
4 x M8 screw, 4 x M8 nut, 8 x washer
Picture shows the use of both articles
2 - Line-up basic set (screws, nuts, washers)
If the weight load of the cabinets is increased, the clamp connectors PRO-
ANR02 also can be used. These cause a further stabilisation of the
cabinet poles. 1 set contains 4 connectors.
Use of clamp connector
without side walls
1 - Line-up openings
in frame
3 - Additional clamp
connector
Use of clamp connector with side walls
Note:
Therefore, the walls must be ordered and with holes
or have to be drilled at construction side.
1 - Clamp connector
2 - Pole of left cabinet
3 - Pole of right cabinet
4 - Side wall of left cabinet
5 - Side wall of right cabinet
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network-/Server Cabinets PRO - Dismounting of the Rack Frame I
Page 6/21
Before unmounting the cabinet roof all walls and doors shall be removed
from the rack frame. Tip: rst, remove only the lower screw of the upper
hinge...
TIPP: „Storing“ the screws in the threads of the poles prevents their loss
... after that remove both screws of the lower hinge.
Finally, remove the remaining screw of the upper hinge.
To remove the rear door, only the lower hinge pin has to be pulled out
of the sleeve. The upper pin stays like it is and is pulled out of the frame
when the door is taken away.
The cabinet frame of PRO series is dismountable extraordinary fast:
An INBUS 8 screw is located inside of the M12 thread (for feet / transport
eyes) at each cabinet corner
View from TOP to the cabinet roof with
M12 thread and inner Allan captive screw (unloosable)
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
After loosening this 4 screws at the roof resp. bottom,
the single parts are dismountable very comfortable and fast.
inserted Allen key (INBUS size 8)
Indicated direction of rotation: Loosen the screw
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
DATASHEET
19” Network-/Server Cabinets PRO - Dismounting of the Rack Frame II
Unloosable: Due to the special construction of the corners, the screws
for roof and bottom are captive and cannot get lost even if they are
loosed.
Now the cabinet roof can be lifted upwards
Page 7/21
and set aside.
Before loosening the cabinet bottom also the
rear cable entry should be removed.
TIPP: also here, screws + brackets don‘t get lost if they stay mounted
Single frame parts in dismounted condistion see next page !
To loosen the oor, the cabinet is placed on the front or back side.
Important: Do not place the cabinet on the side parts !
Removal of the bottom is done like at the roof.
Art.-Nr. PRO-4288GR.G1SVDatei PRO-xx.indd
Beschreibung19” Netzwerk-/Serverschränke PRO
Erstellt Datum Letzte Revision Datum GeprüftDatum
MN21.03.2018MN29.05.2019MN29.05.2019
EFB Elektronik GmbH | Striegauer Str. 1 | 33719 Bielefeld | www.efb-elektronik.de
fon +49(0)521/40418-0 | fax +49(0)521/40418-50 | info@efb-elektronik.de
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.