Eemax SP2412, SP3012, SP3512, SP3208, SP4208 Service manual

...
®
“Single Point”
ELECTRIC INSTANTANEOUS WATER HEATER
INSTALLATION GUIDE AND OWNERS MANUAL
WARNING
BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY
ADJUSTMENTS TO THE UNIT, ALWAYS BE SURE CIRCUIT BREAKER IS OFF
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY OR DEATH
INSTALLER/ CONSUMER RESPONSIBILITIES
READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
OPERATE THIS WATER HEATER. IF THE SAFETY RULES ARE NOT FOLLOWED,
THE UNIT WILL NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH,
SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
WARRANTY OF THIS WATERHEATER WILL DEPEND
ON PROPER INSTALLATION AND OPERATION. THE WARRANTY
WILL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY
WHATSOEVER. THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE
FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION
AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
Eemax Inc., 353 Christian Street Oxford, CT 06478
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS
MANUAL AND LOCAL CODES, OR INTHE ABSENCE OF
LOCAL CODES, WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM
YOUR LOCAL GOVERNMENT, ELECTRIC CO., PUBLIC LIBRARY, OR BY
WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN RD.,
NORTHBROOK, IL. 60062
TEL:1-800-543-6163, 203-267-7890, FAX: 203-267-7975, e-mail: eemaxinc@aol.com
IF YOU REQUIRE HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL
OUR TECHNICAL SERVICE DEPARTMENT TOLL FREE:1-800-543-6163.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING:
MODEL NO.___________SERIAL NO.___________INSTALLATION DATE_____
½’’ PIPE
(5/8’’OD)COMPRES
SION NUT AND
SLEEVE
PART# EX16, EX17
RELAY
PART # EX250-
255
CONTROL BOARD
EX182DP
SPECIFY VOLTAGE
AND MODEL
ELEMENT CARTRIDGE
HEATER MODEL/ORDER REF. CARTRIDGE REF #
SP2412 (120V) EX610SP SP3012 EX480SP SP3512 EX410SP
SP3208 (208V) EX1440SP SP4208 EX1050SP SP8208 EX520SP
SP35 (240V) EX1650SP SP55 EX1050SP SP65 EX890SP SP75 EX770SP EX95 EX630SP
SP3277 (277V) EX260SP SP4277 EX1870SP SP60 EX1280SP SP80 EX960SP SP90 EX850SP SP100 EX760SP
Replacement Parts for “Single Point” Units
3/8’’ COMPRESSION ADAPTOR WITH NUT AND SLEEVE PART#EX68A,B,C
INSTANT COMFORT…ENDLESS SAVINGS
INSTALL THIS WAY UP
ONLY !
UP
relay
UP
GENERAL
This heater must have its own independent circuit, using
a correctly rated breaker and
wires suitable for at least 75 oC operation.
Failure to ground this system may result in death or serious injury.
1) MOUNTING THE UNIT
1) The unit should be mounted as close to the point of use as possible.
2) This unit must only be mounted in the vertical position with the water fittings at the top of the unit. Mounting other than in the vertical upright position WILL cause element burn out.
3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side. Under NO circumstances can these be reversed.
4) Leave a minimum of 8” below the unit for easy replacement of the element.
5) The heater should be fixed to the wall using the four mounting holes at each corner of the backplate.
NOTE: The heater should be installed below the level of all hot water outlets serviced by this heater.
NOTE: PRESSURE RELIEF DEVICE This unit is not required by UL to have a Pressure and Temperature safety relief valve (PTRV). You should check with local codes to find out if one is required in your area. If local codes require the use of temperature and pressure relief valve it should be installed on the outlet hot water pipe before the outlet ball valve.
TROUBLE SHOOTING
SYMPTOM: NO HEAT INDICATOR LIGHT OFF
1) ELECTRIC SUPPLY IS OFF Turn on the main breaker.
2) NO OR LOW WATER FLOW Ensure that the minimum flow rate to switch on your heater is met. Models minimum flow rate = 0.75 gallons per minute “SP8208, 80, 90, 100, 75, 95” Models minimum flow rate = 0.6 gallons per minute “SP60,65” Models minimum flow rate = 0.5 gallons per minute “SP2412, 3012, 3512, 3208, 4208, 3277, 4277, 35, 55” Also check that the inlet filter screen is clear from any debris. This is located in the brass inlet boss.
3) WATER CONNECTIONS ARE REVERSED The correct plumbing configuration is Cold water inlet = right side, hot water outlet = left side.
4) ELEMENT BURNED OUT TURN OFF THE breaker! Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element. The resistance reading should be under 10 ohms. If the resistance is much greater than this value, call Eemax for a replacement element.
5) ECO TRIPPED (High Limit Thermostat) TURN OFF THE FOUR MAIN CIRCUIT BREAKERS! Reset by pushing in red button on each heater module.
SYMPTOM: NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON
1) WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve. See page 3 for temperature rise at various flow rates.
2) INCORRECT POWER SUPPLY Make sure that the unit is connected to the voltage supply specified on the rating label on the the front cover of the unit and no other.
3) ELEMENT BURNED OUT TURN OFF THE breaker! Repeat the steps from paragraph 4 above.
The Eemax “Single Point” heater is specifically designed to be installed “under sink” feeding a SINGLE faucet(5.5kW and lower) It is designed to take in cold water ONLY and heat it to temperatures suitable for hand washing. To obtain optimum performance and energy savings, the unit should be located as near as possible to the point of use. The heater incorporates a constant flow device and should only be used with the faucet aerator supplied with this heater by Eemax. The unit is supplied with compression rings and nuts suitable for direct coupling to 3/8” copper or plastic piping. Do not use additional screwed fittings or pipe dope. Doing so will void the warranty. DO NOT SOLDER PIPES WHILE THE UNIT IS INSTALLED/ DO NOT USE PIPE DOPE OR TEFLON TAPE (serious damage to the electronic flow switch will result).