ProAdvantage
™
Digital Microprocessing Temperature Control for Commercial and Industrial Applications
Performance Features
•
Cut Energy Waste. Flow switch activates heater only on demand
(no standby heat loss)
•
Save Water – "Point of Use"
•
Continuous Hot Water. No storage capacity to run out
•
Easy Installation. Only one cold or hot water line is needed for
installation – 3/4" NPT water ttings (except single module units
use 1/2" compression ttings)
•
External digital temp control
•
Reduces installation cost and material. No T&P relief valve
needed (check local codes) or venting
•
Warranty, ve (5) years limited on leaks, one (1) year parts
•
Field serviceable replaceable cartridge element
•
Aluminum powder coated exterior
Product Specications
Cover: Aluminum Powder Coated
Temperature Control: Range 100°F-140°F, digital touchpad LED
UL listed le number: E86887
U.S. Patent #'s: 4,762,980 and 4,960,976
Single Module Dual Module
Specications
Tankless Electric Water Heater
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specication
Tankless water heater shall be an Eemax ProAdvantage model
number PA____________________
Eemax ProAdvantage model, with digital microprocessing
temperature control capable of maintaining outlet temperature.
Element shall be replaceable cartridge insert. Unit shall have
replaceable lter in the inlet connector. Element shall Nickel
Chrome material. Maximum operating pressure of 150 PSI. Hot
water storage tanks prohibited. Unit shall be Eemax or approved
equal.
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
Triple Module
Information and product specications contained in this document are subject to change without notice. REV 2020-01
19
ProAdvantage
SINGLE PHASE ELEC. CONNECTIONS (1 1/8˝ 3 PL)
Digital Microprocessing Temperature Control for Commercial and Industrial Applications
Specications
Tankless Electric Water Heater
Product Specications
Single Module Models
PA004120T, PA008208T, PA005240T,
PA007240T, PA010240T, PA012240T,
PA008277T, PA010277T
Dimensions: 9.875" x 5.375" x 4"
Weight: 4.5 lb
Rated 25 PSI min
Pressure: 150 PSI max
Element: Single replaceable heating
cartridge insert
Fittings: 1/2" compression
Dual Module Models
PA014240TC, PA016277TC,
PA019240TC, PA020277TC,
PA023240TC
Dimensions: 10.5" x 11"x 4.5"
Weight: 10.5 lb
Rated 25 PSI min
Pressure: 150 PSI max
Element: Dual replaceable heating
cartridge insert
Fittings: 3/4" NPT
Triple Module Models
PA018208T2T, PA024208T2T,
PA018277T2T, PA024277T2T,
PA032277T2T,
Single Phase Model PA028240T2T
Dimensions: 12.5" x 15.5" x 4.5"
Weight: 15 lb
Rated 25 PSI min
Pressure: 150 PSI max
Element: Triple replaceable heating
cartridge insert
Fittings: 3/4" NPT
MODEL NUMBER
VOLTS 120
C
PA004120T
VOLTS 208 Single Phase
C
PA008208T
VOLTS 240*
C
PA005240T
PA005240T (derated 208V performance)
C
PA007240T
PA007240T (derated 208V performance)
C
PA010240T
PA010240T (derated 208V performance)
C
PA012240T
PA012240T (derated 208V performance)
C
PA014240TC
PA014240TC (derated 208V performance)
C
PA019240TC
PA019240TC (derated 208V performance)
C
PA023240TC
PA023240TC (derated 208V performance)
C
PA028240T2T
PA028240T2T (derated 208V performance)
VOLTS 277 Single Phase
PA008277T
PA010277T
PA016277TC
PA020277TC
VOLTS 208 Three Phase Delta
C
PA018208T2T
C
PA024208T2T
VOLTS 480Y/277 Three Phase Wye - neutral leg required
PA018277T2T
PA024277T2T
PA032277T2T
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according
to a 240V applied voltage. Check with local ofcials prior to derating the electrical infrastructure.
† Temperature electrically limited to factory preset temperature.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No.88.
Single Module
kW AMPS
3.5 29 10 AWG 0.3 2.5 48° 24° 16° 12° 10° – –
8.3 40 8 AWG 0.7 2.5 – 57° 38° 28° 23° – –
4.8 20 10 AWG 0.5 2.5 66° 33° 22° 16° 13° – –
3.6 17 10 AWG 0.5 2.5 49° 25° 16° 12° 10° – –
6.5 27 10 AWG 0.7 2.5 – 44° 30° 22° 18° – –
4.9 24 10 AWG 0.7 2.5 – 33° 22° 17° 13° – –
9.5 40 8 AWG 0.7 2.5 – 65° 43° 32° 26° – –
7.0 34 8 AWG 0.7 2.5 – 48° 32° 24° 19° – –
11.5 48 8 AWG 0.7 2.5 – 79° 52° 39° 31° – –
8.7 42 8 AWG 0.7 2.5 – 59° 40° 30° 24° – –
15.0 64(2x32) 8 AWG 0.7 3.0 – 102° 68° 51° 41° 34° –
11.2 52(2x27) 8 AWG 0.7 3.0 – 76° 51° 38° 31° 25° –
19.0 80(2x40) 8 AWG 0.7 3.0 – † 87° 65° 52° 43° –
14.0 68(2x34) 8 AWG 0.7 3.0 – 96° 64° 48° 38° 32° –
23.0 96(2x48) 8 AWG 0.7 3.0 – † 105° 79° 63° 52° –
17.3 83(2x42) 8 AWG 0.7 3.0 – † 79° 59° 47° 39° –
28.5 118(3x40) 8 AWG 0.7 4.0 – † † 97° 78° 65° 49°
20.9 100(3x33) 8 AWG 0.7 4.0 – † 95° 71° 57° 48° 36°
8.0 29 10 AWG 0.7 2.5 – 55° 36° 27° 22° 18° –
10.0 36 8 AWG 0.7 2.5 – 68° 46° 34° 27° 23° –
16.0 58(2x29) 10 AWG 0.7 3.0 – † 73° 55° 44° 36° –
20.0 72(2x36) 8 AWG 0.7 3.0 – † 91° 68° 55° 46° –
18.0 50/phase 8 AWG 0.7 4.0 – † 82° 61° 49° 41° 31°
24.0 67/phase 4 AWG 0.7 4.0 – † † 82° 66° 55° 41°
18.0 22/phase 10 AWG 0.7 4.0 – † 82° 61° 49° 41° 31°
24.0 29/phase 10 AWG 0.7 4.0 – † † 82° 66° 55° 41°
32.0 39/phase 8 AWG 0.7 4.0 – † † † 87° 73° 55°
Dual Module
RECOMMENDED
WIRE SIZE
(75° C/CU)
TURN ON
(GPM)
MAX. FLOW
(GPM)
Triple Module
0.5
GPM
TEMPERATURE RISE °F
1.0
1.5
GPM
GPM
2.0
GPM
2.5
GPM
3.0
GPM
4.0
GPM
20
MOUNTING
4 1/4”
7 7/8˝
1 3/8˝ ELECTRICAL
OUT IN
LOCATIONS
9 7/8˝
CONNECTION
4˝
MOUNTING
LOCATIONS
9 1/4˝ 10 1/2˝
8 1/2˝
4˝
IN
OUT
3/4˝ NPT
ELECTRICAL
4 1/2˝
Information and product specications contained in this document are subject to change without notice. REV 2020-01
OUT
10 1/2˝
MOUNTING
LOCATIONS
7”
14˝
3/4˝ NPT
IN
12 1/2˝
3 PHASE ELEC.
CONNECTIONS
(1 3/8˝)
4 1/2