AccuMix Series
Ideal for Sensor or Metering Faucets. UPC 413.1 Code Compliant
Performance Features
• Eemax exclusive turnkey solution
• Integrated mixing valve meets ASSE 1070-2004
• Meets UPC 413.1 requirements when properly installed
• No scalding or temperature spikes
• Product performance test indicator light
• 99% energy efficient reducing your utility costs
• On-Demand hot water –– never run out
• 0.3 GPM turn on
• Quick temperature ramp up time
• Compatible with all sensor and non-sensor faucets
• Save water – “Point of Use”
• Easy installation – only one cold or hot water line is needed
for installation – integral compression fittings for 1/2” pipe on
BOTTOM (MB Units) or 3/8” on TOP (MT Units)
• Reduces calcification, liming and sedimentation
• Reduces installation cost and material – No T&P relief valve
needed (check local codes)
• Warranty – Heaters, against failure due to leaks of “Heater
Body/Element Assembly”, five (5) years – Parts, one (1) year
• High Temperature Limit Switch (ECO) with automatic reset
• ADA Compliant
Specifications
Electric Tankless Hot Water Heater
Accumix
Product Specifications
Dimensions: 13.5” H x 5” W x 4” D
Weight: 8 lbs.
Cover: Steel Powder Coated
Color: Sandstone
Temperature: Factory set to 105°F
Element: Replaceable Ni Chrome cartridge insert
MT Fittings: 3/8” compression fittings at TOP of unit
MB Fittings: 1/2” compression fittings at BOTTOM of unit
UL listed file number: E86887
U.S. Patent Pending Technology
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specification
Tankless water heater shall be an Eemax AccuMix model
number M_____________________T.
Tankless Water Heater shall be an Eemax AccuMix model,
with digital microprocessing temperature control capable of
maintaining outlet temperature of +/–1°F accuracy, and uses
an ASSE 1070 approved integrated mixing valve to conform
to UPC 413.1. Element shall be replaceable cartridge insert.
Unit shall have replaceable filter in the inlet connector. Element
shall be iron free, Nickel Chrome material. Heater shall be fitted
with 1/2” pipe compression fittings (5/8” OD) or 3/8” (1/2’’ OD)
fittings, to eliminate need for soldering. Maximum operating
pressure of 150 PSI. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal.
MT Version MB Version
3/8”
compression
fittings at
TOP of unit
The wetted surface of this product contacted by water
contains less than 0.25% lead and meets ANSI/NSF 372
1/2”
compression
fittings at
BOTTOM of
unit
Information and product specifications contained in this document are subject to change without notice.
9
AccuMix Series
Ideal for Sensor or Metering Faucets. UPC 413.1 Code Compliant
Specifications
Electric Tankless Hot Water Heater
Accumix
Warning: The temperature of
this heater has been Eemax
factory set at 105°f for hand
washing applications and must
not be adjusted. Tampering
with any adjustments will void
warranty and may cause a
loss of compliance to Uniform
Plumbing Code 413.1. For further
information please contact our
technical support department at
1-800-543-6163.
TEMPERATURE RISE °F
MODEL NUMBER
ACCUMIX MT with 3/8” Compression Fittings at TOP of Unit
MT004120T
C
MT005240T
C
C MT005240T (derated 208V perf.) 240V* 3.6 17A 0.3 12 AWG 1 3/8” Top 49° 25° 16°
MT007240T
C
C MT007240T (derated 208V perf.) 240V* 4.9 24A 0.3 10 AWG 2 3/8” Top 66° 33° 22°
MT010240T
C
C MT010240T (derated 208V perf.) 240V* 7 34A 0.3 8 AWG 3 3/8” Top † 48° 32°
MT004277T
MT008277T
MT010277T
ACCUMIX MB with 1/2” Compression Fittings at BOTTOM of Unit
MB004120T
C
MB005240T
C
C MB005240T (derated 208V perf.) 240V* 3.6 17A 0.3 12 AWG 1 1/2” Bottom 49° 25° 16°
MB007240T
C
C MB007240T (derated 208V perf.) 240V* 4.9 24A 0.3 10 AWG 2 1/2” Bottom 66° 33° 22°
MB010240T
C
C MB010240T (derated 208V perf.) 240V* 7 34A 0.3 8 AWG 3 1/2” Bottom † 48° 32°
MB012240T
C
C MB012240T (derated 208V perf.) 240V* 8.7 42A 0.3 6 AWG 4 1/2” Bottom † 59° 39°
MB004277T
MB008277T
MB010277T
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all
be according to a 208V to 240V single phase applied voltage. Check with local officials prior to derating the electrical infrastructure.
† Units are factory preset to not exceed 105°F.
“C” indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88.
TURN
VOLTS
120V 3.5 29A 0.3 10 AWG 1 3/8” Top 48° – –
240V 4.8 20A 0.3 12 AWG 1 3/8” Top 64° 31° 21°
240V 6.5 27A 0.3 10 AWG 2 3/8” Top † 44° 30°
240V 9.5 40A 0.3 8 AWG 3 3/8” Top † 65° 43°
277V 4.1 14.8A 0.3 14 AWG 1 3/8” Top 56° 28° 19°
277V 8.0 29A 0.3 10 AWG 2 3/8” Top † 55° 36°
277V 10.0 40A 0.3 8 AWG 3 3/8” Top † 68° 46°
120V 3.5 29A 0.3 10 AWG 1 1/2” Bottom 48° – –
240V 4.8 20A 0.3 12 AWG 1 1/2” Bottom 64° 31° 21
240V 6.5 27A 0.3 10 AWG 2 1/2” Bottom † 44° 30°
240V 9.5 40A 0.3 8 AWG 3 1/2” Bottom † 65° 43°
240V 11.5 50A 0.3 6 AWG 4 1/2” Bottom † 79° 52°
277V 4.1 14.8A 0.3 14 AWG 1 1/2” Bottom 56° 28° 19°
277V 8.0 29A 0.3 10 AWG 2 1/2” Bottom † 55° 36°
277V 10.0 40A 0.3 8 AWG 3 1/2” Bottom † 68° 46°
kW
AMPS
ON
(GPM)
RECOM-
MENDED WIRE
SIZE (CU)
# OF 0.5
AERATORS
SUPPLIED/UNIT
WATER
CONNECTIONS
COMPRESSION
FITTINGS
0.5
GPM
1.0
GPM
GPM
1.5
10
MT
13.57
4.14
MB
5.16
Information and product specifications contained in this document are subject to change without notice.
4.10
13.57