RECORD THIS INFORMATION FOR FUTURE REFERENCES
MODEL NUMBER_______________________
DATE OF PURCHASE ___________________
PLACE OF PURCHASE__________________
Manual # GV-F+H, Date:12/08 Part # W498
INSTALLATION AND OPERATING MANUAL
MODEL GF-120
MODEL GH-120
for flush mounting inside a wall only
for surface mounting against a wall only
Important: Instructions must stay with unit. Owner read carefully.
This manual must be read and understood before installation, adjustment, service or
maintenance is performed. This unit should be installed by a qualified technician.
Modification of this product can be extremely hazardous and could result in
personal injury or property damage.
1
IMPORTANT SAFETY INSTRUCTIONS
Polarization Instructions for models H120 and CM120 (with cord) only.
These appliances have a polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
When using an electrical vacuum cleaner, basic precautions should always be followed including the following: Read all instructions carefully before using this vacuum cleaner
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
1.
Do not leave appliance when plugged in. Unplug from an electrical outlet when not in use and beforeservicing. Do not use outdoors or on wet surfaces.
2.
3.
Never operate this vacuum cleaner without a dust bag and filters in place. Close attention is necessary when used by ornear children.Do
4.
not allow unit to be used as atoy. Use only for intended use as described inthis manual. Use only
5.
the manufacturer's recommended attachments and dust bag. Do not use with damaged cord or plug.If applianceis notworking
6.
as it should, has been dropped, damaged, leftoutdoors, orfell into water,return thevacuum cleaner to InterVac or an authorized service dealer for examination and repair.
Do not put any object into openings. Do notuse withany openings
7.
blocked; keep free of dust, lint, hair andany othermaterial that may reduce air flow. When the secondary filter becomes dirty, rinse in warm water or replace with anew filter. Filter should be completely dry before using.
Never drop or insert any object into anyopening.
8.
Turn off allcontrols before unplugging.
9.
Do not pull or carry by cord, donot usecord asa handle,do not
10.
close a door on the cord, or pullcord aroundsharp edgesor corners. Do not run applianceover cord.Keep cordaway from heated surfaces.
.
11.
Do not unplug by pulling on cord. To unplug, grasp the plug, not
the cord.
12.
Keep hair, loose clothing, fingers, and all parts of body away
from any openings and all moving parts.
Do not pick up anything that is burning or smoking, such as
13.
cigarettes, matches, or hot ashes.
Use extra caution when cleaning on stairs.
14.
Do not handle plug or appliance with wet hands.
15.
Do not pick up flammable or combustible liquids such as
16.
gasoline, or use in areas where they may be present.
Do not place objects against the vacuum cleaner. Keep area
17.
clear.
Do not step on the hose or pull the hose forcibly.
18.
Do not pick up large objects such as waste paper or cloth,
19.
which may clog the hose.
Do not install this vacuum cleaner in an area exposed to high
20.
temperatures.
Install this vacuum cleaner in a dry place.
21.
Do not attempt to service the vacuum cleaner. Unit is sealed
22.
and can not be opened without damage to the unit. For service, call your local authorized service deale
r.
SAVE THESE INSTRUCTIONS
LIMITED WARRANTY
InterVac Design Corp. will repair the power unit with new or rebuilt parts, free of charge for six (6) years from the date of original purchase in the event of a defect in materials or workmanship. No cash refunds. Excluded are the following items that require normal replacement: Disposable dust bags, filters, vacuum cleaner tools and vacuum hoses. This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be required before warranty performance is rendered.
You must return your warranty card or register on our website in order to be covered under these provisions
This warranty only covers failures due to defects in materials or workmanship which occurs during normal use and does not cover damage which occurs in shipment or failures which are caused by products not supplied by InterVac Design, or failures which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or commercial use such as hotel, office, restaurant or rental use of the product, or service by anyone other than an authorized service center, or damage that is attributable to acts of God. There are no expressed warranties except as listed above.
LIMITS AND EXCLUSIONS
:
INTERVAC DESIGN SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY. ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,ARE LIMITED TOTHE APPLICABLE WARRANTY PERIOD SET FORTHABOVE. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty last, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights that vary from state to state. If a problem with this product develops during or after the warranty period, you may contact your dealer or our service center. If the problem is not handled to your satisfaction, than write to the Customer Service Center at the company address.
.
2
MODEL: GH-120
Specification: 120 Volt, 11 Amp 50/60Hz, Weight 9 lb
Parts List: Tool Caddy #B051 2 high filtration dust bags Hose Retainer #B053 Paper Template Floor Tool #X404 2 double sided tape pieces Elongated Brush #X251 3 dry-wall anchors Upholstery Tool #X300 1 red push pin Crevice Tool #X200 7 #8 screws Telescoping Wand #X154 Wand Holder #X153
W600
#Y08
urface mounting to Wood
Step 1.
Step 2.
Step 3. Step .
Step 5.
Step 6.
Step 7.
To cover with the vacuum hose as much area as possible, choose a wall or surface that is centrally located
and has an electrical outlet close by. Find a place that is close to the garage door so that you can clean your car in the drive way as well as inside the garage.
Cut paper template from instruction manual, page 11. Tape the template to the wall or a surface at a comfortable operating height or a minimum of 6 inches above the floor. Carefully remove template from the wall and place it into the operating manual for future references .
Attach the enclosed #8 screws to the wall as marked on the template. Keep the screw heads 1/8” from the wall.
Slide the key holes on the back of the vacuum cleaner without the tool caddy over the 4 screw heads and secure
4
by pushing down. If vacuum cleaner is loose re-tighten screws.
Now attach the tool caddy to the top of the vacuum by sliding the ‘dove tails’ into the grooves until the little pin
clicks into the hole of the tool caddy. Reattach the vacuum with the tool caddy over the 4 screw heads.
Attach a screw in the top hole inside the tool caddy.
If you have unstable wall for mounting the unit use all 3 screw holes in the tool caddy. Check to be sure dust bag and motor filter (under dust bag) are in place.
Mark the 4 centers accurately.
The motor filter has to lay flat in all 4 corners, please check.
Surface mounting to Drywall (½ thick) Surfaces:S(see Fig.: A)
Step 1.
Step 2. #W600
Step 3.
Step 4. Step 5. Step 6. Very lightly
Step 7. Step 8.
Step 9.
Step 10.
Step 11.
Step 12. Check to be sure dust bag and motor filter (under dust bag) are in place.
To cover with the vacuum hose as much area as possible, choose a wall or surface that is centrally located
and has an electrical outlet close by. Find a place that is close to the garage door so that you can clean your car in the drive way as well as inside the garage.
Tape the paper template on page 11 to the wall. Align the template so that 2 vertical center points of the template are aligned with center of a 2x4 stud behind the dry-wall.
With an awl or similar pointed object mark the center of the key holes . Carefull remove template from the wall and place it into the operating manual for future references .
With a 3/32 drill bit, pre-drill all 4 holes.
Now use a 5/16 drill bit to enlarge the 2 holes which go through the dry-wall without stud support.
Squeeze the two arms of the plastic anchor together and insert through the hole. hammer the anchor flush
with the dry-wall surface. Insert the red key-pin and push hard to toggle the anchor open behind the dry-wall, remove red key. Attach all four screws (#8) through the anchors and into the stud into the wall. Keep the screw heads
1/8” from the wall surface.
Slide the key holes on the back of the vacuum cleaner, without the tool caddy, over the 4 screw heads and
push down. If the vacuum cleaner feels loose on the screws re-tighten screw heads a little more.
Now attach the tool caddy to the top of the vacuum by sliding the ‘dove tails’ into the grooves until the little pin
clicks into the hole of the tool caddy. Reattach the vacuum with the arch over the 4 screw heads.
Mark only the top screw hole inside the tool caddy. ttach a plastic anchor as described in Step 4 through 8.
only
A
accurately
y
he motor filter has to lay flat in all 4 corners, please check.T
3
Fig.: A
WAND HOLDER Installation:
for wood surface use the 2 screws
1:
supplied with the wand holder package.
2:
for dry-walls use two 1-1/2 long screws from the fastener package. NOTE: the wand holder should be mounted against a wall stud for extra strength.
Fig.: B
4
MODEL: G
F-120
Specification: 120 Volt, 11Amp 50/60Hz, Weight 9 lb
Parts List: Tool Caddy #B051 2 dry-wall anchors, 1 red push pin Hose Hanger #B055 6 #8 screws Hose Retainer #B053 2 high filtration bags Floor Tool #X404 2 double sided tape pieces Elongated Brush #X251 3 wire connectors Upholstery Brush #X300 Paper templates: #W605 Crevice Tool #X200 Wand Holder #X153 Telescoping Wand #X154
#Y08
GROUNDING INSTRUCTIONS for GF-120 , WHEN PERMANENTLY WIRED
This appliance must be connected to a grounded metal, permanent wiring system; or an
equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment-grounding terminal or lead on the appliance.
WARNING:
Disconnect all electrical power to the wall area before installing!
Do not drill near studs where electrical cable may be secured to studs adjacent to receptacles.
Note:
The four mounting holes in the outer corners of the flange of the Vacuum Cleaner must be drilled from the back of the unit with a 3/16” drill bit when the unit is to be recessed into a wall.
To reach with the vacuum hose as far as possible, choose a wall or surface that is centrally located and has an electrical outlet or switch from a 16 amp circuit breaker. Make sure the wall is hollow and there are no pipes or other obstructions in the section you choose.
TIP: Find a place that is close to the garage door so that you can clean your car in the drive
way as well as inside the garage. After you cut the hole for the vacuum paint the back wall inside the hole with a color matching the vacuum for a better look, but not necessary.
Recessed (flush) installation into Drywall
We recommend that the vacuum cleaner be mounted against the side of a wall stud.
Drywall installation: with a 3” dia. hole saw, cut a hole first and check for obstructions! It is easier to
TIP:
re-plaster the 3” dry-wall slug than a large cut-out if you do encounter an obstruction.
Step 1 No
Step 2. , IMPORTANT TIP: Attached the 2 anchors first before you cut the hole for the vacuum!
Step 4.
Step 5. a
Step 6.
Step 7.
The vacuum cleaner should be mounted to the side of a wall stud . Make sure electrical switches or outlets
are on the installation side of the 2X4, because the body of the vacuum cleaner will be tight against the stud when installed. Having the power supply in the same wall cavity of the cut-out will shorten installation time. Tape the template against the wall at a comfortable operating height keep the exhausting air of the vacuum clear.
# for the cut out
W605 - .
Install 14 or 16 gage AWG, 300V minimum Romex cable (use wires rated for at least 95C) from the electrical power supply and pull the power cable through the wall cut-out.
) Open the 2 3/4" x 1 3/8" side cover and pull the 3 inside wires through the opening.
) Insert your 120 volt power supply cable through the Romex clamp and out of the side opening.
b
) With 3 wire nuts connect , and to wires.
d black to black white to white green bare ground conductor
) Tighten the Romex clamp and replace the side cover.
e
Slide the unit, bottom first, into the opening and secure with the four screws. use 2 screws for the 2X4 and 2 screws for the 2 anchors. Do not over-tighten. Check to be sure dust bag and motor filter (under dust bag) are in place.
The motor filter has to lay flat in all 4 corners, please check.
TIP:
: (see Fig.: B)
Refer to the paper template
Recessed into Wood Surface Installation:
Same procedure as above, but do not use the drywall anchors. Pre-drill the 4 outer holes 3/32 dia. and secure
(see Fig.: B)
5
HOW TO OPERATE YOUR VACUUM CLEANER
MODELS: GF-120 + GH-120
NOTE: THE LOWER PART OF THE VACUUM CLEANER WILL BE QUITE WARM WHEN IN USE.
IF THE VACUUM STOPS RUNNING:
THE THERMAL PROTECTOR ON THE MOTOR WILL RESET AUTOMATICALLY AFTER
PLEASE
SEE TROUBLE SHOOTING GUIDE.
ABOUT 1-1/2 HOUR.
A. Connecting and disconnecting the hose
1. Lift the inlet valve cover on the front of the door.
2. Insert hose cuff with a to secure.
3. To remove, turn hose in either direction while pulling hose towards you.
slight twist
.
B. On / Off Switch
1. To start the vacuum cleaner, push the switch to the “I” position.
2. To stop the vacuum cleaner, push the switch to the “O” position.
C: How to change the dust bag,
Replacement bag: Part # Y08 high filtration with Hepa Quality
1. Open the door on the vacuum cleaner by pushing the latch upward and remove both door and dust bag.
2. Carry door and dust bag to the trash container. Remove full bag and discard.
3. Place a new dust bag all the way over the scoop on the door.
4. When closing door, tuck in the left and right corners of the bag, so the door is properly sealed and the latch clicks into place.
: If you break off the vacuum hose inlet cover, simply reattach it by lining up one of the small dimples located on
TIP
the inside of the inlet cover and than press hard on the other side to click into position.
C: To change motor filter, Replacement Part # Y21
1. Remove door and dust bag.
2. Reach into the cavity towards the bottom of the vacuum cleaner and remove the motor filter.
3. Replace the filter with a new filter and tuck in the corners so that the filter lays flat on the grid, with the printed words " facing upward.
4. If necessary, clean the dirty filter by vacuuming or washing in mild soap by hand.
Do not clean in washing machine
THIS SIDE UP!"
(see Fig.: E)
. Let filter dry completely and reuse as needed.
6
D: Replacing Exhaust Filter, Part #Y41:
THIS SIDE UP
Pinch exhaust filter in the middle and pull out. To replace, pinch in the middle and slide in one side first. ( washable by hand)
TROUBLE SHOOTING:
TIP :
If you use our very convenient stretch hose, but require more suction power, we recommend you try our standard central vacuum hose.
Fig.: E
THIS SIDE UP
E. Replacing motor filter
Part # Y21
tuck-in the corners and sides
carefully under the ribs
NOTE: IF MOTOR SUDDENLY STOPS:
TIP:
1. The most
Disconnect vacuum hose from cleaner, hold one end high up in the air and drop a quarter or similar ob­ject into the hose. If the quarter gets stuck the hose is clogged. Try to unclog the hose with a long stick.
2.
The bag is overfilled or fine dust has clogged the bag. The vacuum cleaning tools are clogged.
3.
4.
Vacuuming large amounts of dust other than household dirt, such as dry-wall or fine wood dust can
block the bags pores fast,
The motor filter is dirty and should be cleaned or replaced.
5.
If vacuum unit is installed in a tight compartment and air cannot exhaust, the motor can overheat and
6.
shut off until it cooled down.
The exhaust filter should be checked and washed.
7.
common cause is a clogged hose. See cleaning instructions.
even if the bag is new.
CLEANING THE STRETCH HOSE:
The stretch hose, besides all its’ conveniences, has a tendency to get clogged, especially if you have pets.
lift the hose up on both ends and dispense some liquid detergent into both ends.
a)
with a garden hose, holding both ends still up, fill ¾ with water.
b)
shake hose up and down, let detergent loosen the dirt.
c)
stretch the hose as far as you can ( 2 people required ) and wash the dirt out with the full pressure of the
d)
garden hose. Repeat if necessary.
Hang hose up , let hose drain and dry , it might take 24 hours.
e)
completely
DO NOT PICK UP LIQUIDS, LIT CIGARETTES, HOT ASHES,
RAZOR BLADES, NEEDLES, PINS OR OTHER SHARP OBJECTS!
CAUTION:
7
Floor Tool with rollers
and horse hair
PART# A002
ACCESSORIES
Wand Holder
Part # X153
40’ Stretch Hose
Assembly PART# A002
Elongated Brush for Car
Dash Board PART# A002.
Tool with horse hair
REPACEMENT DUST BAGS: PART # Y08-5 (5 pack) HEPA Type 5 layer fiber filtration
bags for all Intervac Models
NOTE: All Power Units come with 2 Dust Bags
30 Foot Traditional
Central Vacuum Hose
PART #A006
PART # A006B
for Models G,H, F, CM
for Models RM, RMG
OPTIONAL VACUUM TOOLS
Battery Operated Power
Brush with Charger,
PART # X453
2 Part Upholstery
PART # X300
Crevice Tool
PART # X200
Air Turbo Nozzle
for upholstery
PART # X452
Telescoping Wand PART # X154,
INTERVAC reserves the right to make improvements and modifications without notice.