E+E EE892 Data sheet

EE892
The E+E CO2 module EE892 is designed for OEM applications and for demanding environment. A multiple point CO ment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications.
The E+E dual wavelength NDIR CO automatically for ageing effects. EE892 is highly insensitive to pollution
and offers outstanding long term stability.
With its small dimensions and electrical connection via contact pins and pads, EE892 is the optimal choice for OEM devices such as wireless transmitters, hand-helds or data loggers. The measured data, with a
range of up to 10000 ppm, is available on the E2 digital interface.
An optional kit facilitates easy configuration and adjustment of the mod­ule. The measurement interval can be set according to the application
requirements; by this the average current consumption can be reduced to less than 60 μA for battery-operated devices.
Digital CO2 Sensor Module for OEM Applications
and temperature adjust-
2
sensing procedure compensates
2
EE892
Typical Applications
Automotive Data loggers, Hand helds Wireless transmitters Building management Demand controlled ventilation
Outstanding long-term stability
Temperature compensation
Low power consumption
Key features
Autocalibration
Very small size
Technical Data
Measured values
CO
Measurement principle Dual wavelength (non-dispersive infrared technology) NDIR
Working range 0...2000 / 5000 / 10000 ppm Accuracy at 25 °C
0...10000 ppm: < ± (100 ppm +5 % of measuring value) Response time t 60 s without measured data averaging. Temperature dependency typ. ± (1 + CO Calibration interval 2) >5 years Measuring time interval adjustable from 15 s up to 1 h
General
Digital interface E2 (details: www.epluse.com)
Peak current see power consumption graph
Working conditions -40...60 °C Storage conditions -40...60 °C (-40...140 °F) 0...95 % RH (not condensating) 70...110 kPa (10.15...15.95 psi)
1) for averaging output
2
and 1013 mbar
(77 °F and 14.69 psi) 0...5000 ppm: < ± (50 ppm +3 % of measuring value)
105 s with measured data averaging (smooth output)
90
Supply voltage 4.75 - 7.5 V DC Average power consumption
Electrical connection contact pins, edge card socket
2) under normal operating conditions
3) the average power consumption depends on the adjusted measuring time interval
1)
0...2000 ppm: < ± (50 ppm +2 % of measuring value)
concentration [ppm] / 1000) ppm/°C (-20...45 °C) (-4...113 °F)
2
(factory setting: 15 s)
3)
58 µA (at 1h measurement interval) ...3.7 mA (at 15 s measurement interval)
(-40...140 °F) 0...95 % RH (not condensating) 85...110 kPa (12.33...15.95 psi)
1
v1.6 / Modification rights reserved
EE892
EE892
Power Consumption
350
300
250
200
150
120
100
50
Power Consumption [mA]
0
Ø Power consumption in measurement mode 120 mA
350 ms
Measuring time interval 15 s - 1 h
Connection Diagram / Dimensions in mm (inch)
Mounting X (Contact Pads)
2.5 (0.1)“
2.5 (0.1)“
Detail A
Detail A / Connection Diagram:
2.54
(100 mil)
1.25
(50 mil)
1
(40 mil)
5.9
(210 Wmil)
Data
+VB
CLOCK
GND
31.8 (1.3“)
Mounting Y (Contact Pins)
designed for 28 pin socket or PCB soldering
13
(0.51“)
50 (2“) 50 (2“)
3,2 (0.13“)
30 (1.2“)
1.3
(52mil)
DNC
29.2 (1.1“)
2.5 8 (0.1“)
2.5 8 (0.1“)
(600 mil)8.3 (0.3“)
15.2
2.54
5.1 (100 mil)
(0.2“)
Detail B / Connection Diagram:
DNC
+VB
Data
DNC
GND
CLOCK
Detail B
DNC...do not connect
DNC
1.55 (0.06“)
4
(0.2“)
3
(0.1“)
3.2 (0.13“)
30 (1.2“)
Ordering Guide
MEASURING RANGE TYPE OUTPUT MOUNTING
0...2000 ppm
0...5000 ppm
0...10000 ppm
(02) CO (05) contact pins (Y)
(C) E2 interface (2) contact pads (X)
2
(10)
EE892-
EE892-02C2X
measuring range: 0...2000 ppm type: CO output: E2 interface mounting: contact pads
Accessories (see also data sheet “Accessories”)
E2 Test and Configuration Adapter HA011010 E+E Product Configuration Software EE-PCS (Download: www.epluse.com/Configurator)
EE892
v1.6 / Modification rights reserved
Order Example
2
2