E+E Elektronik® Ges.m.b.H. doesn't accept warranty and liability claims neither
upon this publication nor in case of improper treatment of the described products.
The document may contain technical inaccuracies and typographical errors. The
content will be revised on a regular basis. These changes will be implemented in
later versions. The described products can be improved and changed at any time
without prior notice.
GENERAL ................................................................................................................................................... 3
IMPORTANT NOTES .................................................................................................................................. 4
SCOPE OF SUPPLY ................................................................................................................................... 7
GENERAL
For technical data, options and accessories please see EE870 data sheet and operation manual at
www.epluse.com/EE870.
The modular CO
• EE871 interchangeable CO2 probe with E2 digital output. For technical data please see EE871 data sheet and
operation manual (www.epluse.com/EE871)
For readjustment of EE871 please see data sheet and operation manual EE-PCS Product Configuration Software
(www.epluse.com/EE-PCS)
• HA011014 converter board: The converter board supplies the EE871 CO
digital output signal into analogue outputs and Modbus RTU digital interface. The measured data is available
simultaneously on the analogue outputs and on the Modbus interface. Technical data, setup and operations
instructions for HA011014 are detailed in this document.
• Connecting cable between EE871 CO
cables, as ordered:
• HA010809 ......... 1 m length
• HA010810 ........ 2 m length
• HA010811 ........ 5 m length
• HA010812 ........ 10 m length
transmitter EE870 consists of following components:
2
probe and HA011014. EE870 scope of supply includes one of the following
2
.
3
probe and converts its
2
Page 4
IMPORTANT NOTES
• Connecting the supply voltage to the modbus terminals may destroy the device.
• The HA011014 converter board is supplied as a component and must be installed in accordance with the valid ESD
guidelines and properly protected against enviromental influences.
Probe
Sensing head
Filter cap
CO2 Sensing cell
• The device shall not be exposed to extreme mechanical stress. The sensing head of the probe and mostly the sensing
cell might not be exposed to any mechanical stress.
• The probe must be operated with the filter cap on at all times. Do not touch the sensing cell or electronics inside the
sensing head.
• A long response time indicates a dirty filter cap, as it might happen in polluted applications. Do not attempt to clean
the filter cap; it would only cause its clogging. Replace the filter cap by an E+E original one, order no. HA010116.
• While replacing the filter cap take utmost care to not touch the sensing cell and the electronics.
• This device is not appropriate for safety, emergency stop or other critical applications where device malfunction or
failure could cause injury to human beings.
CONNECTIONS / MOUNTING
Modbus Dip-switch
Jumper "Bus
termination resistor"
Modbus terminals
Terminals for cable EE871
+5Vwhite
SCLblack
SDAblue
GNDbrown
Shieldgrey
Jumper "Fast/Slow"
Supply terminal*
LED:
Jumper "Output Range"
Analogue outputs*
On = OK
Fast flash = Error
* Very important: for failure-free operation and performance according to the specs the supply GND and the
measurement GND must be wired separately.
4
Page 5
TECHNICAL DATA
6
6
78 (3.08“)
96 (3.78“)
Gewicht: 30g
Digital CO2 Probe EE871
Measuring principle Dual wavelength (non-dispersive infrared technology) NDIR
Measurement range / 0...2000 ppm: < ± (50 ppm + 2 % from the measured value)
Accuracy at 25 °C and 0...5000 ppm: < ± (50 ppm + 3 % from the measured value)
1013 mbar
0...3 %:
0...5 %: Response time t
60 s without measured data averaging
Temperature dependency 0...2000 ppm:
(-20...45 °C)
0...10,000 ppm:
0...3 %:
0...5 %:
Housing / Protection class Plastic PC / Housing IP65
Cable length max. 10 m
Electromagnetic compatibility EN61326-1
(Industrial enviroment) EN61326-2-3
Conversion Board
Supply voltage 10-35 V DC / 10-28.8 V AC
Supply current 120 mA at 24 V DC / 300 mA at 10 V DC
Protection class IP00
Electrical connection screw terminal size: 2.5 mm
Analog outputs 0-1 V; 0-5 V; 0-10 V -1 mA < IL < 1 mA
selectable by jumpers 0-20 mA; 4-20 mA R
Resolution 12 bit
Response time t
Modbus RTU setup with dip-switches (see operation manual)
Temperature dependence Voltage: typ. ±0.2 mV/°C (0 – 1V)
typ. ±0.5 mV/°C (0 – 5V)
typ: ±0.6 mV/°C (0 – 10V)
Current: typ. ±1 μA / °C
EE870 Operating conditions -40...60 °C
EE870 Storage condition -40...60 °C (-40...140 °F)0...100 % RH (not condensating) 70...110 kPa (10.15...15.95 psi)
1) For averaging output
1)
(77 °F...14,69 psi)0...10,000 ppm: < ± (100 ppm + 5 % from the measured value)
< ± (1,5 % from full scale + 2 % from the measured value)
105 s with measured data averaging (smooth output)
Dip-switch S1 and S2 "Baud rate" set on 19200
Dip-switch S3 "Stopbit" set on "one"
Dip-switch S4 "Parity" set on "even"
Dip-switch S5 - S10 "Address" set on "13"
(activate S5/S7/S8)
Jumper "Termination resistor" set on "No"
Register addressParameter nameProtocol address
0
ASCII
HIGH BYTE - main version
LOW BYTE - sub version
9
ASCII
0x19
0x1A26
0x1B
0x1C28
0x1D
0x1E30
0x1F
0x2032
0x21
0x2234
0x23
0x2436
0x25
0x2638
0x27
0x2840
0x29
0x2A42
0x2B
0x2C44
0x2D
0x2E46
0x2F
0x3048
0x31
0x3250
-
-
fast
CO
2
slow
CO
2
Gain Voltage
Offset Voltage
Gain Current
Offset Current
Measuring range
Measuring range
Analogue Output
low (V)
Analogue Output
high (V)
Slow or Fast
25
27
29
31
33
35
37
39
41
43
45
47
49
FLOAT
ASCII
6
Page 7
OPERATION OUTDOORS
For outdoor applications, the probe of EE870 must be used with the radiation shield order no. HA010507, which protects
the device against rain, snow, ice, and solar radiation. The convertor board must protected IP65 (NEMA4) or better.
Ø105
174
Ø5
20
44
94
W
122
ACCESSORIES
Replacement probe EE871-HRxJ2 see data sheet EE871
Cable M12 - flying leads (1 m (39.37") / 2 m (78.74") / 5 m (196.85") / 10 m (393.70")) HA010809/10/11/12
Mounting flange for probe HA010212
Radiation shield HA010507
PFTE Filter cap HA010116
H
filter capHA010122
2O2
Protection cap for the M12 cable socket HA010781
Protection cap for the M12 probe plug HA010782
SCOPE OF SUPPLY
- EE871 probe according to ordering guide
- Test report according to DIN EN10204 - 2.2 for EE871
- Conversion board HA011014
- Connecting cable HA0108xx
- Operation manual
- Test report according to DIN EN10204 - 2.2 for conversion board