E+E EE82 Specifications

EE82
EE82 is optimized for harsh climate control applications such as life stock barns or storage of fruit and vegetables. The robust enclosure has been tailored for best protection of the CO2 sensing cell. The air diffuses first through the filter on the front cover into the instrument enclosure and then through a second membrane filter into the CO2 sensing cell. As there is no flow through the sensing cell, this is very well protected against pollution.
The CO2 measurement is based on the Non-Dispersive Infrared (NDIR) technology. A patented auto-calibration procedure compen­sates for the aging of the infrared source and leads to outstanding long-term stability.
CO2 Switch for harsh environment
EE82 is available with measuring ranges of 0...2000, 0…5000 or
EE82
0…10000ppm. The switch threshold and hysteresis can be set with potentiometers on the printed circuit board.
The EE82 with snap-in mounting flange and M12 electrical connector allows for easiest installation, replace­ment or removal of the device during site cleaning and sterilizing operation.
Typical Applications Features
fruit and vegetable storage life stock barns
easy installation
compact housing
auto-calibration
Technical Data
Measured values
Measuring principle Non-Dispersive Infrared Technology (NDIR)
Sensing element E+E Dual Source Infrared System Measuring range 0...2000 / 5000 / 10000ppm Accuracy at 25°C and 1013mbar 0...5000ppm: < ± (50ppm +3% of measuring value)
0...10000ppm: < ± (100ppm +5% of measuring value) Response time Temperature dependence typ. 2ppm CO Long term stability typ. 20ppm / year Sample rate approx. 15s
Switch Output
Max. switching voltage 50V AC / 60V DC Max. switching load 0.7A at 50V AC 1A at 24V DC Min. switching load 1mA at 5V DC Contact material Ag+Au clad
General
Supply voltage 24V AC ±20% 15 - 35V DC Current consumption typ. 10mA max. 0.5A for 0.3s Warm up time Housing / protection class PC / IP54
Electrical connection M12 plug Electromagnetic compatibility EN61326-1 FCC Part 15 EN61326-2-3 ICES-003 ClassB Working temperature and conditions -20...60°C Storage temperature and conditions -20...60°C
1) warm up time for performance according specification
(77°F) 0...2000ppm: < ± (50ppm +2% of measuring value)
τ
< 195s
63
1)
< 5 min
2/°C
(-4...140°F) 0...100% RH (non-condensing) (-4...140°F) 0...95% RH (non-condensing)
144
v1.8 / Modification rights reserved
EE82
EE82
Dimensions (mm) Connection Diagram
80
(3.15”)
80 (3.15”)
snap-in
51 (2”)
relay status
ON
OFF
Hysteresis [% of WR]
switching off
25% of WR
Level [% of WR]
on
switching
1000500
2000
ppm
mounting flange
NO = normally open NC = normally closed WR = working range
Ordering Guide Order Example
MEASURING RANGE MODEL
0...2000ppm
0...5000ppm
0...10000ppm
(2) CO2 Switch (CS) (5)
(10)
EE82-
Measuring range: 0...5000ppm Model: CO2 Switch
EE82-5CS
EE82
v1.8 / Modification rights reserved
145