E+E EE771, EE772 Specifications

EE771/EE772
Inline Flow meter for compressed air and gases
The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the measure­ment of flow in pipelines DN15 (1/2”) up to DN80 (3”). Measure­ment of for instance the usage of compressed air, nitrogen, CO O2, argon or other non-corrosive, non-flammable gasses.
The flow meters are setting new standards in terms of measure­ment accuracy and reproducibility thanks to their application­specific adjustment during production. As such, the EE771/ EE772 is adjusted under a pressure of 7 bar. The unique mounting concept with a measurement valve with shut-off function permits rapid installation and removal of the device for periodical calibration. It simultaneously ensures high measurement accuracy through exact and reproducible position­ing in the pipe.
The core design of the flow meter is based on the E+E hot film sensor element, which is produced using the most modern thin film technology. This flow sensor features excellent long-term stability, a fast response time and an extremely high degree of reliability.
flow sensor
2
EE771 Compact
DN15 (1/2“) - DN80 (3“)
detail
Two outputs are available, for further processing of the measure-
EE772 remote probe
ment data. Depending on the application, these outputs can be configured as analogue (current or voltage), switch output or as pulse output for the measurement of the consumption.
Bus interface for Modbus RTU or M-Bus
Optionally, the ow meter is available with an additional bus
interface for Modbus RTU or M-BUS (Meter-Bus).
Configuration software
The ow meter can be congured conveniently, to meet the re­quirements of the application with the standard conguration soft-
ware and the integrated USB interface.
Attribute
Sensor exchange under pressure
with short ow interruption
Sensor exchange under pressure
without ow interruption
pipeline DN15...DN50 (1/2“...2“) pipeline DN40...DN80 (1 1/2“...3“) Additional assembly of dew point-
and pressure sensors max. working pressure 16 bar 232 PSI max. working pressure 40 bar 580 PSI
EE771 EE772
Functionality of the software:
Conguration of the output (scale / set point)
2-point user calibration for ow and temperature
Readout of the counter values
Reset of min / max values and counter
Indication of the measurement value
Typical Applications Features
Measurement of consumption of compressed air Compressed air counter Mass flow measurement of industrial gases
quick sensor exchange at line pressure
Bus interface for Modbus RTU or M-Bus
high accuracy ± 1.5 % of reading
factory adjustment under pressure
exceptional reproducibility
broad working range of 1:400
very service friendly
196
v4.6 / Modification rights reserved
EE771/EE772
EE771/EE772
EE771 - Measurement valve with shut-off function
The measurement valve with shut-off function allows the exact alignment of the sensing head within seconds during instalment and removal, with only interrupting the process flow for a short moment. The measurement valve is suitable for pressures up to 16 bar
(232 PSI) and
available for pipe diameters DN15 (1/2") to DN50 (2").
EE772 - Gauge mounting block with hot tap valve
The unique assembly concept with one mounting valve permits simple installation and removal of the sensors for regular calibration, and also ensures a high level of measurement accuracy via precise and reproduc-
ible positioning of the ow sensor in the pipeline.
The gauge mounting block with hot tap valve is used in applications where
ow interruption is not permissible. The ow meter can be removed for calibration or maintenance with no ow interruption.
The gauge mounting block with hot tap valve assembly is suitable for appli­cations up to 40 bar (PN40) and is available for line sizes of DN40 (1 1/2“) to DN80 (3“). The additional option of integrating dewpoint or pressure sensors saves on installation costs. The gauge mounting block with hot tap valve makes it easy to set up a comprehensive compressed air monitoring system.
measuring remove
Construction
The ow meter consist of the transmitter and the mounting valve. The transmitter is modular and consist of the
probe and the evaluation electronics. The measurement probe contains the sensor element and the measure­ment electronics, in which the data of the factory calibration is stored. The enclosure with the signal conditioning is mounted either on the measurement probe (compact) or is remote with a sensor cable up to 10 meter
evaluation electronics with optional display
quick coupling (accessory)
probe with sensor and measurement electronics
Measurement valve with shut-off function
EE771
hot tap valve
EE772
Gauge mounting
block
sampling cell for dew point sensor (accessory)
dew point sensor EE371 or EE355 (accessory)
(33 feet).
Measurement of consumption (totalizer)
The EE771/EE772 holds an integrated counter for the usage. The amount is indicated in the display and stored; the data will not be lost due to a power outage. The availability of the consumption amount as a free
congurable pulse output is another helpful feature.