EE354
Miniature Dew Point Transmitter
down to -20 °C Td (-4 °F Td)
The EE354 was developed for monitoring dew point down to -20 °C
Td (-4 °F Td). The high measurement accuracy of ±1 °C Td (±1.8 °F
Td) in the typical working range of a refrigeration dryer makes the
EE354 the ideal solution for OEM manufacturers.
Integration into the measurement task is considerably simplified
thanks to its highly compact design and exceptional robust stainless
steel housing. The measurement values are issued on an analog
4-20 mA and a digital Modbus RTU output. Furthermore, excellent
long-term stability and temperature compensation across the entire
measurement range are important features of the EE354.
Using the free EE-PCS configuration software and the Modbus USB
converter (available as an accessory), the scaling of the analog
output can be modified. This also permits one and two-point
adjustments by the user.
Typical Applications Features
EE354
Compressed air monitoring
Refrigeration dryer
Measurement range -20...50 °C Td (-4...122 °F Td)
Accuracy ±1 °C (±1.8 °F) for refrigerant dryers
MODBUS RTU digital interface
Pressure-tight up to 80 bar
Technical Data
Measured Values
Dew point (Td)
Sensor HC1000
Measurement range -20...50 °C Td (-4...122 °F Td)
Accuracy at 20 °C1)
Response time t
at 20 °C < 30 sec.
90
Dew point [°C Td]
-10
-20
40
20
10
0
0
-10
±1 °C
±1.8 °F
203030
10
Gas temperature [°C]
±2 °C
±3.6 °F
±3 °C / ±5.4 °F
405050
Output
Analog output (scalable) 4 - 20 mA (3-wire technology) R
Maximum adjustable scaling -40...80 °C Td (-40...176 °F Td)
Digital interface MODBUS RTU
< 500 Ohm
L
Temperature dependence ±0.005 % of the measuring span / °C
General
Supply voltage 10*)...28 V DC
Power consumption at 24 V DC <40 mA
Pressure range of use 0...80 bar (0...1160 psi)
Housing / protection rating Stainless steel 1.4404 (AISI 316L) / IP65
Electrical connection
Sensor protection Stainless steel sinter filter
Temperature / humidity operating range -40...60 °C (-40...140 °F) / 0...100 % RH
Storage temperature range -40...60 °C (-40...140 °F)
Electromagnetic compatibility in accordance with EN61326-1 EN61326-2-3
Industrial environment
1) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2 x standard deviation).
The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) Flange receptacle for self assembly included in scope of supply.
2)
M12x1 5-pin plug
*)
10V+0.02*R
Output 4...20 mA
(1160 psi)
60
L
110
v1.5 / Modification rights reserved
EE354
EE354
Dimensions in mm (inch)
ISO
NPT
Ø12
34.5 (1.36)
(0.5)
G1/2“
140 (5.5)
AD27
77 (3)
92 ( 3.6)
89 (3.5)
Ø30
(1.2)
4
5
1 2
Connection Diagram
3
Plug
1...V+
2...Analog output 4-20 mA
3...GND
4...RS485 A (=D+)
5...RS485 B (=D-)
1/2“NPT
AD22
74 (2.9)
Modbus Map
The measured values are 32Bit float values. The factory-set slave ID is 243 as integer 16Bit value. This ID can be
customised in the register 0x00 (value range 1 - 247 permitted). For Modbus setting please see Application Note
AN0103. The factory setting of the transmission rate is: baud rate 9600, parity even, and stop bit 1.
FLOAT: INTEGER:
Register
address
30032 0x1F dew point Td
30042 0x29 frost point Tf
Protocol
address
Parameter
name
Register
address
60001 0x00 Slave-ID
60002 0x01 RS485 setting
Protocol
address
Parameter
name
Ordering Information
Pressure-tight screw connection
Software configuration
Physical parameters Dew point temperature Td [°C/°F] TD
Analog output Frost point temperature Tf [°C/°F]
Td/Tf output scaling xxx (acc. to table
(in °C or °F)
Measured value unit
G1/2" thread A
1/2" NPT thread C
at dew point <0°C, the frost point is issued
metric [°C] M
non metric [°F] N
Scaling Range
TD or TF
002 -40...60 007 0...60 024 -20...80 048 -20...50 090 32...120
003 -10...50 008 -30...70 025 -20...60 060 -20...40 091 32...140
004 0...50 022 -40...80 047 -20...150 083 -40...140
EE354-T63G
TF
scaling ranges)
Accessories
M12x1 5pin mating plug suitable for customer-specific assembly HA010708 sampling cell with quick connector HA050102
M12x1 5pin connection cable socket/flying leads 1.5 m HA010819 sampling cell NPT with bleed screw HA050107
M12x1 5pin connection cable socket/flying leads 5 m HA010820 basic sampling cell HA050103
M12x1 5pin connection cable socket/flying leads 10 m HA010821 stainless steel sinter filter
Order example
EE354-T63GA/TD060M
Pressure-tight screw connection: G1/2" thread
Output: Dew point Td
Scaling of output: 4-20 mA = -20...40 °C Td
Measured value unit: metric [°C]
EE354
v1.5 / Modification rights reserved
Modbus - USB converter for EE35x
HA010103
HA011013
111