EE310
High-End Humidity and Temperature Sensor
for Industrial Applications
The EE310 is optimized for best reliability in industrial applications up to
180 °C (356 °F) and 20 bar (290 psi). In addition to highly accurate measurement
of the relative humidity (RH) and temperature (T), the device calculates all other
humidity related parameters.
Measurement Performance
The EE310 employs high-end E+E humidity sensing elements manufactured in
state-of-the-art thin lm technology, which are the prerequisite for outstanding
measurement accuracy.
Long-Term Stability
The E+E proprietary coating protects the sensing elements against corrosive
and electrically conductive pollution, which leads to outstanding long-term
stability even in harsh environment. With the appropriate choice of lter cap,
the EE310 tackles even challenging industrial applications.
Versatility
The EE310 is available for wall or duct mount as well as with remote probe. It
features an IP65 / NEMA 4 polycarbonate or stainless steel enclosure which
facilitates installation and maintenance. The enclosure can accommodate a
100…240 V AC supply unit or various interface modules.
Display and Outputs
The measured data is available on two analogue outputs, on the RS485
(Modbus RTU) or Ethernet-PoE (Modbus TCP) interface and on the alarm
(relay) outputs.
The TFT colour display shows simultaneously up to four measurands and
offers extensive setup and diagnosis features. The data logging function saves up to 20000 measured values for each
physical quantity. The logged data can be displayed graphically directly on the device or easily downloaded over the
USB interface.
Congurable and Adjustable
The conguration and the RH and T adjustment of the EE310 can be performed either using the display and the push
buttons or with the free EE-PCS Product Conguration Software via the USB interface.
Features
3.5“ TFT Colour Display
» shows up to 4 measurands
simultaneously
» layout and measurands
freely selectable
» data logger for 20.000
values per measurand
» logged data shown
graphically
» diagnosis functions
» intuitive device setup with
push buttons
Probe
» working range up to 180°C (356 °F)
and 20 bar (290 psi)
» protective coating for sensing
elements
» pluggable versions available
Inspection certicate
» According DIN EN 10204 - 3.1
Enclosure
» IP65 / NEMA 4 protection class
» polycarbonate or stainless steel
» easy mounting and service
Outputs
» 2 analogue outputs current / voltage
» error indication according NAMUR
» Modbus RTU / Modbus TCP
» 2 alarm outputs
» congurable via display or software
USB Service Interface
» conguration, adjustment and
rmware update
» download logged data
» 4 status LEDs
12
v2.3 / Modification rights reserved
EE310
EE310
Protective sensor coating (option C1)
The E+E proprietary sensor coating is a protective layer applied to the active surface and leads of the sensing elements.
The coating substantially extends the lifetime and the measurement performance of the E+E sensor in corrosive environment
(salts, off-shore applications). Additionally, it improves the sensor’s long term stability in dusty, dirty or oily applications by
preventing stray impedances caused by deposits on the active sensor surface.
Dimensions in mm (inch)
ENCLOSURES
Polycarbonate
180 (7.09“)
166 (6.54“)
153 (6.02“)
71
(2.80“)
Stainless steel
218 (8.58“)
200 (7.87“)
186 (7.32“)
73
(2.87“)
54 (2.13“)
PROBES
T1: Wall mount
53 (2.09“)
2)
L
T2: Duct mount
5.1
(0.20“)
200 (7.87“)
104 (4.09“)
75 (2.95“)
5.1
(0.20“)
110 (4.33“)
T5: Remote probe up to 180 °C (356 °F)
1)
15 (0.60“)
∅12 (0.47”)∅13 (0.51”)
code „cable length“
2)
L
code „probe length“
1)
T10: Pressure tight probe up to 20 bar (300 psi)
2)
L
2)
L
∅12 (0.47”)
min. 23 (1“) / max. 164 (6.5“)
∅12
adjustable
(0.47“)
code „cable length“
200 (7.87“)
1/2“ ISO or
1/2“ NPT
1)
15 (0.60“)
1) Refer to ordering guide
2) L = lter length; refer to data sheet "Accessories"
Technical Data
Measurands
Relative humidity (RH)
Working range 0...100 % RH
Accuracy1) (incl. hysteresis, non-linearity and repeatability)
-15...40 °C (5...104 °F) RH ≤90 % ± (1.3 + 0.3 % * mv) % RH
-15...40 °C (5...104 °F) RH >90 % ± 2.3 % RH mv = measured value
-25...70 °C (-13...158 °F) ± (1.4 + 1 % * mv) % RH
-40...180 °C (-40...356 °F) ± (1.5 + 1.5 % * mv) % RH
Temperature dependence of electronics typ. ± 0.01 % RH/°C (0.0055 %RH / °F)
Response time < 15 s with metal grid filter at 20 °C (68 °F) / t
EE310
v2.3 / Modification rights reserved
90
13