![](/html/6a/6a75/6a7536f3f51896e366c849d6ece11f1cc3287da7e422c47adaabeea1b17f1c66/bg1.png)
EE040
The EE040 is dedicated for cost effective measurement of the relative
humidity (RH) and temperature (T) in OEM applications. It employs the high
quality EEH210 RH and T sensing element, which stands for reliable and long
term stable measurement performance.
The electronics board and the components are protected by a special varnish.
In addition, the proprietary E+E coating protects the RH sensor against dirt,
dust and corrosion, which leads to excellent long-term stability even in polluted
environment.
The measured data is available on two analogue voltage outputs.
The EE040 design, the plug connection and the mounting flange included in
the scope of supply facilitate the design-in, installation and replacement.
OEM Humidity and Temperature Sensor
Features
• Compact design
• Easy installation and replacement
• Excellent price / performance ratio
Model T18
Model T2
Technical Data
Measurands
Relative Humidity
Working range 0...100 % RH
Accuracy1) at 20 °C (68 °F) ± 3 % RH (30...70 % RH) ± 5 % RH (0...95 % RH)
Output signal (0...100 %) 0 - 2.5 V
Output load
Response time τ63 < 45 s duct mount
< 30 s duct mount with lateral openings
Temperature
Output signal 0 - 2.5 V
Output load ≥ 5 kΩ
Accuracy1) at 20 °C (68 °F) ± 0.3 °C (0.54 °F)
General Data
Supply voltage UV 5 V DC ±10 %
Current consumption typical 2 mA without load
< 3.5 mA at 5 kΩ load
Start up time typ. 4 sec.
Electrical connection appropriate for Molex 6471 (4 pins) and female crimp contacts 4809 555L
Housing material PPO – GF20, UL94HB approved
Protection class connector side: IP30
front side: IP50 (duct mount)
IP20 (duct mount with lateral openings)
CE compatibility according2) EN61326-1 EN61326-2-3
Industrial environment
Working conditions T = -40…+85 °C (-40…185 °F)
RH = 0…100 % (non condensing)
Storage conditions T = -40…+60 °C (-40…140 °F)
RH = 0…95 % (non condensing)
1) Traceable to intern. standards, administrated by NIST, PTB, BEV... . The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2
(2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement).
2) EE040 is not protected against surge
≥ 5 kΩ
v1.1 / Modification rights reserved
EE040
![](/html/6a/6a75/6a7536f3f51896e366c849d6ece11f1cc3287da7e422c47adaabeea1b17f1c66/bg2.png)
Protective Sensor Coating
The E+E proprietary sensor coating is a protective layer applied to the active
surface of the sensing element.
The coating substantially extends the lifetime and the measurement
performance of the E+E sensor in corrosive environment. Additionally, it
improves the sensor’s long term stability in dusty or dirty applications by
preventing stray impedances caused by deposits on the active sensor
surface.
Dimensions (mm/inch)
EEH210 RH and T
sensing element
sensor coating
sealed
solder pads
only for duct mount
with lateral opening
35.1 (1.38")
(1.52")
38.6
43.2 (1.7")
52 (2.05")
Ø 4.4
(0.17")
60 (2.36")
48 (1.89")
Ø 24 (0.94")
3
(0.12")
Ordering Guide
Model
Filter
Output signal 0 - 2.5 V no code
Output 1 relative humidity (0...100 % RH) no code
Output 2
Scaling output 2 low
Scaling output 2 high
duct mount T2
duct mount with lateral openings T18
plastic grid, no filter F1
metal grid filter F3
temperature [°C] no code
temperature [°F] MB2
0 no code
value SBL value
50 no code
value SBH value
EE040-
Order Example Accessories
EE040-T18F3SBL-20SBH40
Type: duct mount with lateral openings
Filter: metal grid filter
Output signal: 0 - 2.5 V
Output 1: relative humidity (0...100 % RH)
Output 2: temperature [°C]
Scaling output 2 low: -20 °C
Scaling output 2 high: 40 °C
EE040
v1.1 / Modification rights reserved
Connection cable 2 m (6.6 ft) (HA010305)
5 m (16.4 ft) (HA010306)