EE04
Miniature Humidity and
Temperature Transmitter
The high quality, compact EE04 humidity and temperature
transmitters are optimised for OEM applications. Highest
performance with respect to accuracy and long term stability
is combined with low costs for large quantities. The SMD
humidity sensor HC103 series, state of the art electronics
and dedicated housing are offering an excellent price /
performance ratio.
An optional filter assures optimal protection against dirt. For use
in high pollution or corrosive environment the sensors and
electronics can be protected with a special E+E coating.
There is an EE04 version model available with extra air slots on
the side allowing for very fast response times.
EE04-FTB
The linear output voltage for relative humidity can easily be
processed further. The temperature output signal is provided by a voltage divider with passive NTC sensor.
Fast and easy installation is possible by using the provided mounting flange.
with extra air slots
EE04-FTO
on the side
Typical Applications
air conditioning in automobiles
humidifiers and dehumidifiers
copy machines
warehouses
home appliances
excellent price / performance ratio
low power consumption
small dimensions
high long term stability
easy installation
traceable calibration
Technical Data
Measuring Quantities
Relative Humidity
Humidity sensor HC103
Working range 0...95%RH with coating 0...100%
Accuracy at 25°C
Traceable to intern. standards, administrated by NIST, PTB, BEV...
Humidity output linear analogue voltage 0...100%RH. ∧ 0.1xU
e.g.: for U
Load resistor R
Response time τ
type O: < 30s (without filter and without coating)
Temperature
Temperature output Voltage divider: NTC (10kOhm at 25°C/77°F) with pull down resistor (10kOhm)
Calculation T
output voltage
Calculation output voltage
out of T
[°C]
(77°F) ± 3%RH (40...60%RH) ± 5%RH (0...95%RH)
= 5VDC : 0...100%RH = 0.5V...4.5V (50%RH = 2.5V)
V
R
T
[K]
NTC
= T
=
> 5kOhm
10000 x U
U
Out
+ 273.15
[°C]
V
- 10000
R
= 10000 x e
NTC
T
=
[K]
11.726 + ln
3496
(
T
[K]
3496
Load
at 25°C (77°F) type B: < 45s (without filter and without coating)
63
out of
[°C]
R
NTC
(
10000
- 11.726
...0.9xUV
V
)
)
T
= T
[°C]
U
=
Out
[K]
10000 x U
R
( )
Features
- 273.15
v
+ 10000
NTC
Working temperature -40...85°C (-40...185°F)
General Data
Voltage supply (UV) 5V DC ±10%
Current consumption typical 1.4mA without load
< 3.5mA at maximal load
Sensor protection grid / metal grid filter or coating
CE compatibility according
1)
EN61326-1 EN61326-2-3
Industrial Enviroment
1) EE04 is not protected against surge
1
v2.5 / Modification rights reserved
EE04
EE04

Dimensions (mm)
Housing material: PPO - GF20
UL94HB approved
Connection Diagram
1 mm = 0.03937” / 1” = 25.4 mm
Protection class:
Sensor side: IP50 (type B)
IP20 (type B and O)
Connector side: IP30
The circuitry shows the typical A/D conversion of the
analogue output signals. A reference voltage or
calibration is not required. The voltage supply can vary in
the range 5V ±10%.
(not included in the sope of supply EE04)
Ordering Guide
MODEL TYPE HUMIDITY OUTPUT T-SENSOR FILTER COATING
(for type B only) (for (3) only)
humidtiy+temperature (FT) duct (B) linear 0,1...0,9 x U
duct with extra metal grid filter above grid (6) without coating (--)
EE04-
air slots on the side (O)
Accessories
connection cable 2m (6.6ft) (HA010305)
5m (16.4ft) (HA010306)
(6.56ft or 16.4ft)
(4) NTC, 10k at 25°C (A) only grid, no filter (3) with coating (HC)
V
Order Example
EE04-FTB4A3-HC
model: humidity and temperature
Type: duct
output: linear 0.1 - 0.9 x U
T-sensor: NTC
filter: only grid, no filter
coating: with coating
V
EE04
v2.5 / Modification rights reserved