Edwards Signaling Series 96DV2 AdaptaBeacon Installation Guide

EDWARDS
Installation Instructions for Catalog Series 96DV2(*)-N5
AdaptaBeacon
®
Signals
Description
The catalog number 96DV2(*)-N5 AdaptaBeacon signal is a UL listed small strobe light. The signals are suitab le for indoor or outdoor (weatherp roof) installation and ha ve type 4X enclosure protection. They are suitable for installation in the Di vision 2 locations listed in Table 1.
These signals are designed for mounting on 1/2" (13 mm) NPT conduit.
Electrical Specifications
Rated Voltage ................................................. 120V 50/60 Hz
Current ..................................................................... 0.10 Amp
Installation
Install in accordance with the latest edition of the National Elec­trical Code and local r egulations.
WARNINGS
To reduce the risks of igniting hazar dous atmo­spheres and electric shock, ensure that power is disconnected before installing the signal.
To prevent leakage and a potential shoc k hazard, when mounting outdoor s the signal m ust be installed with the lens or dome facing directl y up.
Maintenance
Cleaning
CAUTION
To prevent damage to the lens, do not use abrasive materials or cleaners.
Periodically clean the AdaptaBeacon lens surf ace, to maintain optimum light visibility . The lens may be cleaned with a soft cloth or sponge using w ater or a mild detergent solution. Ensure that the lens is completely dry before assembling the signal.
Strobe Tube Replacement
WARNINGS
To reduce the risks of igniting hazar dous atmospheres and electric shock, ensure that power is disconnected before installing the signal. connect power until installation has been completed and unit is tightl y assembled and secured.
To prevent leakage and a potential shoc k hazard, use care when disassembling the signals to prevent tearing of the gaskets.
Refer to Table 2 for the requir ed strobe tube.
Do not
1. Refer to F igure 1. The signals require 1/2" (13 mm) NPT conduit (not supplied). Route the 18" (457 mm) wire leads coming from the bottom of the signal mounting base through the conduit. Thread the conduit into the signal mounting base.
2. Using wire nuts (not supplied), connect field wiring to signal wiring. Connect the green ground wire leads using wire nuts (not supplied). Insert the wires into an appropriate electrical junction box.
1. Refer to Figure 2. Remo ve the scre w in the clamp ring, remove ring, and set aside. Carefully lift the lens straight up and off the signal mounting base, being careful not to damage the strobe tube or lens gasket. If the lens adheres to the gasket on the signal base do not force apart by hand b ut car efully pry the lens off using a thin blade scre wdriver.
CAUTION
To prevent damage to the str obe tube, handle the strobe tube only by the base .
Troubleshooting
2. Grasp the strobe tube by its base and pull straight up from its
If the strobe light fails to operate, make sure there is power to the signal. If there is po wer and the strobe still f ails to operate , re­place the strobe tube as dir ected in the Strobe Tube Replacement section.
*The letter in this position signifies the color of the supplied lens. A - amber, B - blue, C - clear, G - green, M - magenta or R - red.
socket. Install the new strobe tube by aligning the connector on the base of the tube with the mating soc ket. Carefully press down into the soc ket.
3. Assemble the signal.
4. Turn on power and verify that the strobe operates.
P-047550-1385 ISSUE 4 © 1998
Table 1. Di vision 2 Loca tions
Class Division Group Temp. Code
I 2 A, B, C, D T3C (160°C, 320°F)
II 2 F, G T6 (85°C, 185°F)
III T6 (85°C, 185°F)
Table 2. Re placement Parts
Catalog Number or
Component Part Number
Strobe tube 91B-ST
Lens 96-L(*)
*The letter in this position (A - amber , B - blue, C - clear , G - green, M ­magenta or R - red) signifies the color of the lens; for example, a red lens for the 94DV2 series signal is 93-LR.
Figure 1. Conduit Mounting
P-047550-1385 ISSUE 4
Figure 2. Str obe Tube Replacement