94PLEDM Series Rotating Polaris LED Beacon
Installation Sheet
To install the beacon:
1. Release the latch on the clamp ring and remove the ring
holding the protective dome to the signal base. Lift the
dome straight up off of the beacon base (Figure 1).
2. Loosen the three screws in the keyhole slots in the base of
the lens, turn the lens clockwise, and lift it off of the LED
light source support plate.
Description
The 94PLEDM Series Rotating Polaris LED Beacon is UL and
cUL listed for general signaling use. The beacon is available in
120 VAC or multivoltage 12 VDC, 24 VAC, or 24 VDC models.
There are six lens colors to choose from, and a choice of black
or gray bases. The beacon utilizes high-power LED lights and
is suitable for indoor or outdoor use. The beacon is provided
with an enclosure rated for NEMA Type 4X and IP66.
The beacon is well suited for high ambient noise level areas,
especially where ear protection must be worn. The beacon is
also ideal for high vibration applications and areas where long
lamp life is advantageous. The beacon features a 360-degree
beam of light with 16 user-selectable flash or rotation patterns
including Steady. The patterns are selected by pressing the
Edwards logo push button. The factory setting is Light Burst.
The beacon is designed to be mounted on 3/4 in. NPT conduit
(indoor or outdoor). To maintain the NEMA Type 4X and IP66
ratings for outdoor installation, the beacon must be mounted
with the dome facing directly up. When installing the beacon
indoors in dry environments, it can be mounted in any position.
Installation
Install the beacon in accordance with the applicable
requirements in the latest edition of the National Electrical
Code, Canadian Electrical Code, and local codes.
WARNINGS
Electrocution hazard. To prevent electrical shock, ensure
that power is disconnected before installing the beacon
Electrocution hazard. To prevent leakage and potential
electrical shock, use care when disassembling the beacon
to prevent tearing of the permanently affixed gaskets
provided for the environmental integrity and ratings.
Electrocution hazard. To prevent leakage and potential
electrical shock when mounting outdoors, install the
beacon with the lens or dome facing directly up.
3. Remove the three screws holding the LED light source
support plate to the beacon base.
4. Gently grasp the LED tower and carefully lift the support
plate off of the beacon base.
Note: The beacon mounts on a 3/4 in. NPT conduit pipe.
The female threaded entry is located on the bottom of the
base.
5. Route the field wiring from the appropriate power source
through the conduit, and then through the conduit
entrance hole in the beacon base.
6. Install the base on the conduit. Wrench-tighten for a leak
free seal.
7. Wire in accordance with “Wiring” below.
8. Place the connected wires inside the base and
reassemble the beacon (Figure 1).
9. Apply power and verify that the beacon operates properly.
Wiring
Wire this unit in accordance with all applicable local codes and
standards and the local authority having jurisdiction.
To wire the beacon for 120 VAC:
1. Using wire nuts (not supplied), connect the field wiring to
the beacon wiring.
2. Connect the beacon’s black lead to hot, and the white lead
to neutral. Connect the beacon’s green lead to the
grounding point located in the signal base.
To wire the beacon for 12 VDC:
1. Using wire nuts (not supplied), connect the field wiring to
the beacon wiring.
2. Connect the beacon’s red lead to positive (+), and the
black lead to negative (−).
Note: The beacon is designed to be conduit mounted.
© 2014 UTC Fire & Security Americas Corporation, Inc. 1 / 4 P/N 3101962-EN • REV 02 • ISS 24JUN14
To wire the beacon for 24 VAC/VDC:
1. Connect the field wiring to the beacon wiring using wire
nuts (not supplied).
2. Connections depend on the voltage supply. Choose the
connections that match your power supply:
24 VAC: Connect the black lead to hot, and the red lead to
neutral.
24 VDC: Connect the red lead to positive (+), and the
black lead to negative (−). Connect the green lead to the
grounding point located in the beacon base.
Selecting the flash or rotation pattern
The beacon can be configured with one of 16 user-selectable
flash or rotation patterns using a push button (membrane
switch). The push button is located in the center of the
Edwards “shield logo” on the base of the beacon (Figure 1).
Table 1: Flash and rotation patterns
Pattern Description
1. Steady On steady
2. S65 65 flashes per minute (FPM)
3. Light Burst 1,000 FPM (seven pulses),
440 ms off,
Repeat
4. Singular Burst 120 FPM
5. Binary Burst 65 double FPM
6. Quad Burst 65 quad FPM
7. iBurst 750 FPM (nine pulses),
480 FPM (one pulse),
85 FPM (six pulses),
460 FPM (one pulse)
8. Rotating 70 RPM 70 Rotations per minute
9. Rotating 84 RPM 84 Rotations per minute
10. Rotating 115 RPM 115 Rotations per minute
11. Rotating 180 RPM 180 Rotations per minute
12. Slow Rotating with Burst 4 rotations (84 RPM),
2 flash pulses (750 FPM),
Repeat
13. Flash Rotating with Burst 3 rotations (174 RPM),
4 flash pulses (750 FPM),
Repeat
14. Quad Flash with Pop 4 pulses (650 FPM), 204 ms off,
1 pulse (650 FPM), 356 ms off,
Repeat
15. Variable Rotating 164 RPM repeated in 6.6 s. on/off
cycles
16. Variable Flashing 248 FPM repeated in 4.1 s. on/off
cycles
To select a flash or rotation pattern:
1. Press and hold the push button for one second to switch
the beacon to the next pattern (Table 1).
2. Press and hold the push button for three seconds to set
the beacon to the first pattern (Steady).
Maintenance
Lens and dome replacement
WARNING: Electrocution hazard. To prevent electrical shock,
disconnect the beacon from the supply circuit and allow five
minutes for stored energy to dissipate before disassembling.
To replace the lens or dome:
1. Release the latch on the clamp ring and remove the ring
holding the protective dome to the signal base. Lift the
dome straight up off of the signal base.
2. Loosen the three screws in the keyhole slots in the base of
the lens. Turn the lens clockwise and lift it straight up off of
the support plate.
3. Replace the lens by turning it counter-clockwise in the
keyhole slots, and then tightening the three screws.
4. Replace the dome and reinstall the clamp ring.
Cleaning
Caution: To prevent damage to the lens or dome, do not use
abrasive materials or cleaners.
Periodically clean the lens surface with a soft cloth or sponge
and water or a mild detergent solution to maintain optimum
light visibility. Make sure the lens is completely dry before
assembling the beacon.
Figure 1: Installation
(1) Dome
(2) Lens
(3) Screw (3X)
(4) LED tower
(5) Screw (3X)
(6) LED light source support plate
(7) Beacon base
(8) Clamp ring
(9) Push button
2 / 4 P/N 3101962-EN • REV 02 • ISS 24JUN14