Installation Instructions for the
7005-G5 Hotel Room Annunciator
Description
The 7005-G5 Hotel Room Annunciator Kit aler ts hearing-impaired individuals inside a room that someone is present outside the room. The horn/strobe is mounted inside the room. When the pushbutton outside of the room is pressed for 5 seconds, the signal is activated. The 7005-G5 Hotel Room Annunciator Kit contains: Pushbutton (Cat. No. 620), Pushbutton Mounting Plate (Cat. No. 147-10), Horn/Strobe (Cat. No. 6536-G5), and Transformer (Cat. No. 592). You can purchase each item separately from your local Edwards distributor.
Installation
A qualified electrician familiar with National Electrical Code and local code requirements must install this product. F ailure to follow the safety precautions in this instruction sheet could result in product or property damage, severe personal injury or death.
W ARNING
T o reduce the risk of shock, do not connect AC power until installation is complete.
1. Install Cat. No. 620 Pushbutton and Cat. No. 147-10 mounting plate (Figures 1 and 2)
a. Insert the back of the pushbutton through the hole in the
mounting plate. Press on the button until it is properly seated within the hole.
b . Install a single gang 2" x 4" (51 mm x 102 mm) electrical
box using suitable hardware.
c. Extend black and white wires using 18 AWG wire and
connectors (not supplied). Route extended wires to the horn/strobe and transformer (polarity is not important). Ground in accordance with local codes and regulations.
d. Mount the pushbutton switch onto the electrical box
using 2 screws supplied with the Cat. No. 147-10 mounting plate.
e. If additional pushbuttons are required, follow steps a and
b above. Then, extend black and white wires using 18 A WG wire and connectors (not supplied). Route extended wires to the previously installed pushbutton switch and connect wire leads (Figure 1).
2. Install Catalog No. 6536-G5 horn/strobe (Figures 1 and 4).
WARNING
T o reduce the risk of shock, do not remo ve lens or tamper with unit when the circuit is energized. Disconnect power and allow five (5) minutes for stored energy to dissipate before starting work or disassembly . High energy could be stored in the strobe circuit once it is energized.
The 6536-G5 horn/strobe can be mounted on any single gang 2" x 4" (51 mm x 102 mm) electrical box, double gang 4" x 4" (102 mm x 102 mm) electrical box, or standard 4" x 4" (102 mm x 102 mm) junction box with a plaster ring.
a. Install an appropriate electrical box using suitable
hardware.
b. Connect one wire from the 620 pushbutton to one of the
horn/strobe wires (polarity is not important). c. Extend the remaining horn/strobe wire to the transformer. d. Mount the horn/strobe onto the electrical box using two
screws (supplied).
3. Install Catalog No. 592 Transformer (Figures 1 and 3). a. Select a metal electrical box that can be grounded. Mount
the transformer onto the electrical box (Figure 3) so that
it has ground continuity to the box and conduit system. b. Install the box using suitable hardware. c. Ground the box in accordance with local codes and
regulations. d. Connect the remaining pushbutton wire to one of the
terminals marked 24V 20VA. e. Connect the horn/strobe wire to the second terminal
marked 24V 20VA. f. Connect the transformer's primary wire leads to an
appropriate 120V A C power source.
4. When all connections are completed, press the pushbutton and verify operability of the horn/strobe.
Maintenance
Perform regularly scheduled testing at least twice a year or more often as dictated by local authorities having jurisdiction.
The 7005-G5 Hotel Room Annunciator is not serviceable or re­pairable. Should it fail to operate properly, contact the supplier for replacement.
Horn/strobe V oltage 24V 50/60 Hz 24V DC Horn/Strobe Current 175 mA 125 mA
Transf ormer - Primary 120V
CHESHIRE, CT 203-699-3300 FAX 860-677-7746
Table 1. Specifications
- Secondary 24V 20VA
P-047550-1874 ISSUE 1 © 1999
8V 10VA
16V 10VA
24V 20VA
2 1/4"
(57 mm)
2 1/8"
(54 mm)
2"
(50 mm)
31/32"
(24.6 mm)
2 5/16"
(56.7 mm)
Grounded
metal electrical
box for 592
Additional Cat. No. 620 and Cat. No. 147-10 (purchased separately)
592 Tr ansformer
Electrical box for Cat. No. 620 and
Cat. No. 147-10
Electrical box for Cat. No. 620 and
Cat. No. 147-10
To 120V AC
power source
120V 60 Hz
24V 20VA
Figure 1. Connecing Catalog No. 7005-G5 Hotel Room Annunciator
2 3/4"
(70 mm)
Mounting screws
Pushbutton
To 591
4 1/2"
(114 mm)
ROOM FOR
HANDICAPPED
PLEASE DEPRESS
BUTTON
5 SECONDS
To 6536-G5
Figure 2. Catalog No. 620 and Catalog No. 147-10
Electrical
box for
6536-G5
S
Surface Mounting:
Use foot-mounts
Enclosed Mounting: Mount inside a standard two gang electrical box using a Catalog 593 plate.
Figure 3. Catalog No. 592 Transformer
Horn/
Strobe
H
Mounting on Box: Remove appropriate 1/2" (13 mm) knockout from electrical box. Loosen the screw from transformer bracket and position the transformer on the back box so that the bracket extends into the box. Tighten the screw.
FRONT VIEW
Horn
Mounting screws
P-047550-1874 ISSUE 1
SIGNAL
STROBE
4 9/16"
(116 mm)
Strobe
4 1/2"
(114 mm)
_
+
Figure 4. Catalog No. 6536-G5 Horn/Strobe
BACK VIEW
To 591 To 620
Factory installed wires