VISUAL SIGNALS
FEATURES
> Weatherproof
> Hazardous Location Listed
> Motor driven reflector
> 100W Bayonet Base Halogen
Lamp
AGENCY APPROVALS
> UL 1638 Listed
> cUL Listed
> UL Listed for Class I, Division 2,
Groups A, B, C & D; Class II,
Division 2, Groups F & G; and
Class III hazardous locations.
> UL 1604 Listed
AdaptaBeacon
®
Rotating Light
Division 2 Rated, NEMA
Type 4X, 100W Halogen Bulb
58 Series
The Edwards 58 Series AdaptaBeacon is a high profile, heavy duty
rotating beacon in a NEMA Type 4X enclosure designed to meet
hazardous location requirements in industrial, commercial, or
institutional applications. The polycarbonate dome allows for easy
cleaning.
The light mounts to 3/4" (19mm) NPT conduit. It may be corner
mounted using the Cat. No. CBR, corner mount bracket, or wall
mounted using the Cat. No. WBR, wall mount bracket. See
AdaptaBeacon Accessories, page 3-118. For weatherproof
applications, the unit must be mounted vertically, with the dome
facing up.
Domes are available in six colors: red, amber, blue, green,
magenta and clear.
Ideally suited for applications where high ambient noise levels
make audible signals difficult to hear or other types of visual
signals (strobes or flashing lights) hard to distinguish. It can be
used to inform of equipment status changes, communicate
malfunctions, or alert personnel to security breaches.
D-04
3-28
© Copyright 2004 Edwards
TECHNICAL INFORMATION
1 3/4"
(44mm)
8 1/16"
(205mm)
3/4"
(19mm) NPT
VISUAL SIGNALS
7 7/8"
(200mm)
Lens Replacement Revolution Electrical Lamp Replacement
Cat. No. Color Dome Rate Ratings Ratings Lamp
58R-N5-100WH Red 94DV2-DR 75 rpm
58A-N5-100WH Amber 94DV2-DA 1.0 Amp 1620 candlepower
58B-N5-100WH Blue 94DV2-DB 1,000 hours**
58G-N5-100WH Green 94DV2-DG
58M-N5-100WH Magenta 94DV2-DM
58C-N5-100WH Clear 94DV2-DC
*Manufacturer's lumen rating.
**Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle.
120V AC 50/60 Hz 1,800 lumens* 100Q/CL/DC/120V
HAZARDOUS LOCATION LISTINGS
Class Division Group Operating Temperature Code
I 2 A,B,C,D T1 (450C, 842F)
II 2 F,G T6 (85C, 185F)
III 1 T6 (85C, 185F)