Edwards Signaling 53 User Manual

Installation and Maintenance Instructions for
Catalog Series 53 AdaptaBeacon® Signals
Description
The catalog series 53 Adaptabeacon signals are dc operated rotating lights. The signals may either be conduit mounted or direct surface mounted and are suitable for indoor or outdoor (weatherproof) installation. A hardware kit is included with the signals for direct mounting applications.
Specifications
Catalog Rated Number Voltage Current
53(*)-E1 12V DC 1.8A 53(*)-G1 24V DC 1.0A 53(*)-FY 36V DC 1.0A 53(*)-K1 48V DC 0.7A
*The letter in this position of the catalog number signifies the color of the supplied dome. A - amber, B - blue, C - clear, G - green, M - magenta, or R - red
Installation
CAUTION
Direct Surface Mounting
a. Remove the two knock-outs for the mounting screws
from the bottom of the base. See Figure 1 for the location of knock-outs.
b. Place the gasket provided in the hardware kit on the
mounting surface and mark the center of the three holes in the gasket on the surface. Remove the gasket and drill a 3/8" (9.5 mm) hole at each of the marked positions.
c. Install the two rubber expansion plugs provided in the
hardware kit into the two outer holes in the mounting surface as indicated in Figure 2.
d. Route the wiring from the required power source for
the signal (refer to the signal's label for the voltage rating) through the center holes in the mounting surface, gasket and base.
e. Align the holes in the gasket with the holes in the base.
Insert the two screws with lockwashers provided in the hardware kit through the mounting holes inside the base and align the screws with the rubber expansion plugs as shown in Figure 2. Press the base firmly against the mounting surface.
3. Using wire nuts (not supplied), connect the signal's red wire lead to the positive (+) po wer source lead and connect the white wire lead to the negative (-) power source wire. Place the connected wires inside of the base and reassemble the signal on the base.
Ensure that power is disconnected before installing the signal.
1. See Figure 1. Remove the screw in the clamp ring, remov e the ring and lift off the dome.
2. Install the base using one of the following applicable procedures.
CAUTION
When installing indoors, the signal may be mounted with the dome facing either directly up or down. For outdoor installation, the signal must be installed with the dome facing directly up.
Conduit Mounting
a. Route the wiring fr om the required power source for
the signal (refer to the signal's label for voltage rating) through a 1/2" (13 mm) NPT conduit (not supplied) and through the conduit entrance hole in the base.
b. Install the base on the conduit.
Maintenance
CAUTION
Always disconnect power before disassembling the signal.
Lamp Replacement
Refer to the "Replacement Parts" for the required lamp. Dis­connect the power, remo v e the scre w in the clamp ring, remove the ring and lift the dome off the signal. Replace the lamp.
Cleaning
CAUTION
Abrasive materials or cleaners must not be used to clean the dome.
The signal's dome should be periodically cleaned to maintain optimum light visibility. The dome may be cleaned with a soft cloth or sponge using a mild detergent. Dry the dome thor­oughly before replacing.
ADAPTABEACON is a registered trademark of the Edwards Company.
P-047550-0738 ISSUE 4 © 1997CHESHIRE, CT 203-699-3000 F AX. 203-699-3075
Figure 1. Catalog Series 53 Rotating Light Figure 2. Direct Surface Mounting of Signal
Replacement Parts
The replacement parts listed below for the 53 series signals are available from your local Edwards distributor.
Catalog Number Replacement Lamp Replacement Dome
*Specify color of the replacement dome by adding the letter A, B, C, G, M or R to the catalog number; for example, a red dome for the 53(*)-E1 series signal is 52-LR.
P-047550-0738 ISSUE 4
53(*)-E1 1076 52-L(*)
53(*)-G1 1638 53(*)-FY 1062 53(*)-K1 P-041695-0086