VISUAL SIGNALS
FEATURES
> Weatherproof
> 40 Watt Halogen Lamp
> Optically designed fresnel lens
> Cast base can be utilized as
junction box
AGENCY APPROVALS
AdaptaBeacon
®
Steady-on Lights
PLC Compatible
50SIN Series
The Edwards 50SIN Series AdaptaBeacon steady-on lights are
designed to meet continuous visual signaling requirements. The
unique double fresnel lens is optically engineered to maximize
brilliance. This is accomplished with a series of complementing
fresnels that cause the dome to “fill” when the light is operating.
Beam distance is also increased with fresnel lenses. The
polycarbonate lenses are available in six colors: red, amber, blue
and green, magenta and clear.
> UL 1638 Listed
> cUL Listed
Designed for indoor or outdoor installation. May be direct, 1/2"
(13mm) conduit, or box mounted on a 4" (102mm) octagon box on
any plane. However, vertical installation ensures maximum beam
width projection. For weatherproof installations units must be
mounted vertically with dome up. May be corner mounted using the
Cat. No. CBR, corner mount bracket, or wall mounted using the Cat.
No. WBR, wall mount bracket. Cat. No. 92-GRD lens guard is
available for additional protection against lens breakage. See
AdaptaBeacon Accessories on page 3-118.
Ideally suited for light duty applications where a continuous steady-
on incandescent light signal is required or where ambient noise
makes audible signals difficult to hear. The gasketed weatherproof
design assures installation acceptability in most industrial and
commercial locations.
D-04
3-14
© Copyright 2004 Edwards
TECHNICAL INFORMATION
5 7/8"
(149mm)
2"
(51mm)
6"
(152mm)
1/2"
(13mm)
NPT
VISUAL SIGNALS
3/4"
(19mm)
Cat. No. Color Lens Ratings Ratings Lamp
Lens Replacement Lamp Electrical Replacement
50SINR-N5-40WH Red 92-LR 40 Watts 120V 50/60 Hz 50LMP-40WH
50SINA-N5-40WH Amber 92-LA 265 lumens* 0.29 Amps
50SINB-N5-40WH Blue 92-LB 3328 candlepower
50SING-N5-40WH Green 92-LG 20,000 hours**
50SINM-N5-40WH Magenta 92-LM
50SINC-N5-40WH Clear 92-LC
*Manufacturer's lumen rating.
**Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle.
SIGNAL INPUT LOAD CHARACTERISTICS*
Operating Max. off state Continuous on Surge (inrush/duration)
Cat. No. Voltage leakage current (mA) Current (mA) Amps/milliseconds
50SIN( )-N5-40WH 120V AC 60 Hz 25 290 0.47/8
*This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal.
© Copyright 2004 Edwards
D-04
3-15