Edwards Signaling 391-BT GuardSwitch Catalog Page

Safety Switch
4.22''
10.72cm
3.12''
7.92cm
0.55''
1.40cm
0.11''
0.28cm
1.28''
3.25cm
0.17''
0.43cm
0.22''
0.56cm dia.
0.24''
0.61cm
3.75''
9.53cm
0.05''
0.13cm
0.80''
2.03cm
sensing face
sensing face
391-BT GuardSwitch
Actuator
391 Switch
Applications
• Machine Tool Machinery • Presses
• Withstands Corrosive and • Meets ANSI, Semi S2 & Extreme Washdown European Safety Standard for Environments the Highest Machine Risk
• Packaging Machinery Category 4 when used with
General Specifications
Enclosure Seamless 304 Stainless Steel Temperature Range -40°F to 180°F (-40°C to 80°C) Environmental Hermetically Sealed Contact Switch Encapsulated in P NEMA Rating 1, 2, 4, 4X, 5, 12, 12K Protection Class IP 67 Response Time 1 msec (individual circuits) The two circuits do not switch simultaneously and depend on the speed of the guar A delay less than 50 msec is typical. Life Cycles 100,000 Under Full Load; Up to 200,000,000 Under Dr Lead Types/O.D. 18/4 SJTOW (K) / 0.34" (0.86cm) 22/4 P
VC Jacketed (J) / 0.19" (0.48cm)
UL/CSA/TUV All Models
olyurethane
d closure.
y Circuit
300-BT SERIES
SAFETY
Electrical Specifications
Circuit Circuit Contact Load MAX Switching MAX Switching No. Type Config. Rating Voltage Current
1 Switch N.O. 40W/VA 48VAC/VDC 1.0ADC, 0.7AC
File E 122942 LR89176 U9880128199005 When used with INT Safety Monitor Relay
2 Tamper N.C. 10W/VA 48VAC/VDC 0.3A 2 w/optional LED N.C. 0.1–1.4W 48VDC(3V drop) 30mA
Order Information
Part Number Configuration Minimum Maximum Range Length
391-BT-06K DPST: 1 N.O., 1 N.C. 0.3"(0.8cm) 0.6"(1.5cm) 1.2"(3.0cm) 6' (1.8m) 391-BLT-12J DPST: 1 N.O., 1 N.C. w/ LED 0.3"(0.8cm) 0.6"(1.5cm) 1.2"(3.0cm) 12' (3.6m)
Warning— Each electrical rating is an individual maximum and cannot be exceeded!
1
Configuration with actuator away from the switch
2
Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects. Testing is required to determine actual sense
range for specific applications.
Contact
1
Sense Range2 Sense Range2 Break Lead
Loading...