Edwards Signaling 371-BT User Manual

www.edwardssignaling.com
P/N 1033317 • REV C • REB 26FEB13
GuardSwitch™ Series 300
Description
The 371-BT Series DPST safety interlock switch is designed for use with safety monitored relays or monitored circuits. To achieve the optimum Series 300 defeat resistant feature of the 371-BT, both the switch cir
cuit (Circuit 1) and the tamper
circuit (Circuit 2) must be connected.
Notes:
1. Environmental: Pollution Degree II
2. Correct use of this control device is an essential part of proper machine cycle control.
3. Failure to follow ALL instructions could lead to serious bodily injury or death.
4. Maintenance to be done by qualified personnel only
5. The connecting cables between the INT devices and the switches must be located in an IP 23 type enclosure (minmum).
6. The mounting for the switch and the actuator magnet must be accomplished per this specification.
7. Non-removable hardware must be used for installation.
8. The housing of the 300-BT must be connected to the PE (Primary Earth) ground circuit via a lock washer on the mounting screw. The PE ground symbol must be placed adjacent to the screw.
To verify switch operation with an ohmmeter:
Set range at 20 mega ohms (switches with triac output, set ohm range at 20 kilo ohms). For a normally open switch, the meter will read a high impedance with the actuator away. It will read very high to infinity range (triac switches will read high kilo ohm to infinity range) with the actuator within sense range. You will see the opposite reading for a normally closed switch.
Dimensions
0.24''
0.42''
1.07cm
0.64''
1.63cm
0.64''
1.63cm
0.61cm
0.24''
0.61cm
2.33''
5.92cm
0.83''
2.11cm
2.03''
5.16cm
5.75''
14.61cm
5.27''
13.39cm
5.75''
14.61cm
5.26''
13.36cm
1.10''
2.79cm
0.22''
0.56cm dia.
0.28''
0.71cm
1.51''
3.84cm
1.49''
3.78cm
1.12''
2.84cm
Safety Interlock Switch
371-BT
371-BT
Installation
Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not over-torque mounting hardware.
1. Position the switch and actuator so the labels are reading in the same direction. (See Figure 1.)
2. Mount the switch on the stationary frame of the machine and mount the actuator on the moveable guard, door or gate. Keep the switch and actuator within the listed sense range. (See Ordering Information.)
See Figure 2 or recommended mounting configurations.
3. Mounting on a ferrous material will effect the sense range a minimum of 50%. However, a 1/4" non-ferrous spacer positioned under the actuator and/or switch should restore most of the lost sense range.
4. For best protection against operator defeat, mount with non-removable screws, bolts or nuts (see Accessories).
5. Caution! When not used with a INT safety relay, particular care must be taken to determine the actual load of the switch circuit. High voltage transients from coils, motors, contactors, and solenoids must be considered. Transient protection, such as back-to-back zener diodes (TransZorb such loads to ensure that maximum ratings of the switch are not exceeded. Not recommended to be used with tungsten filament loads because of high current inrush surges. Line capacitance and load capacitance must be considered. Excessive line capacitance can be caused by cable lengths over 50' when using a maximum 48 VAC. A resistor can be added in series to limit the inrush current (at least 48 Ohms for 24V applications). The resistor can be added in series just before the load. The voltage drop and the power rating of the resistor must be considered. Voltage drop = I•R; Watts = I
2
R (I = maximum continuous current of the load).
®
) or an RC network, is recommended for
6. When mounting the switch on an ungrounded machine, ground the switch housing by connecting your ground lead to one of the switch mounting screws.
Figure 1
Actuator
sensing face
CIR. 1
CIR. 2
BLK
WHT
BLUE
RED
S1
S4
S2 S3
Switch
sensing face
conduit
Mounting Configurations
Figure 2
Perpendicular
Actuation
Best Best Not Recommended
The parallel actuation can result in on/off/on signal if the actuator passes by the switch rather than coming to rest in proximity to it. This is NOT a recommended configuration for safety interlock applications.
Door
Actuation Parallel Actuation
Pivot Actuation
Good
*Circuits shown with magnet actuator away from switch.
S1 Normally open reed switch, closed when actuator is within 0.6" S2, S3 Normally open reed switches, will close if misaligned or tampered with a
standard magnet
S4 Biased closed reed switch, open when actuator is between 0.3" and 0.6"
N.O. circuit: Black and white wires. N.C. biased tamper circuit: Red and blue wires.
Wiring Diagram for Category 3
Inputs shown with safety gates/guards in closed position. One Series 300-BT GuardSwitch™ required for each safety gate.
(–)
INT-03-230: 230V AC INT-03-120: 120V AC INT-03-024: 24V DC
(+)
Required Fast or Slow-Acting Fuse: (250V, 5x20 mm F) INT-03-230: 40mA INT-03-120: 80mA INT-03-024: 1/4A
Required Fast or Slow­Acting Fuses: 4A (250V, 5x20 mm F
230 VAC
60 VDC
RESET
L1 L2 1 2 X1 X2 Y1 Y2
+
Safety Monitor Relay INT-03
OUTPUTS
SAFE AUX.
A
BCD
LOADS
N.O. N.C.
EFG
W
B
H
L
T
K
*300-BLT-
*Or other DPST GuardSwitch
(See the 300-BT Series installation instructions)
Note – The LED on the BLT model will be ON when the guard is open
Fuses: 1 A (250 v)
Multiple DPST GuardSwitches – Shown with actuators in position, all guards closed.
120 VAC
30 VDC
Series Circuit
R
B
E
L
D
U
The L.E.D of the BLT model will be on when the guard is open. If multiple guards
are open, L.E.D will be dimmer. The maximum number of GuardSwitches that can
be used is 50, although troubleshooting and line resistance must be considered.
(Do not exceed 30 Ohms of combined contact and line resistance. Each GuardSwitch
will have less than 0.5 Ohms of resistance.)
W H T
R
B
E
L
D
K
*300-BLT-
B L U
Parallel Circuit
R
W
B
E
H
L
D
T
K
*300-BLT-
B L U
GuardSwitchTM Series 300