Warning! To avoid switch failure determine the actual load of the switch circuit and take steps to protect the switch from voltage spikes, current inrush and line/load capacitance using the following recommendations.
• Surges from coils, motors, contactors, solenoids and tungsten filaments. Transient protection, such as back-to-back zener diodes (Transorb) or an RC network, is recommended for such loads to ensure that maximum ratings of the switch are not exceeded.
Voltage drop = I • R
2
Watts = I ( I = maximum continuous current of the load)
To verify switch operation with an ohmmeter:
Set range at 20 mega ohms (switches with triac output, set ohm range at 20 kilo ohms). For a normally open switch, the meter will read a high impedance with the actuator away. It will read very high to infinity range (triac switches will read high kilo ohm to infinity range) with the actuator within sense range. You will see the opposite reading for a normally closed switch.
• R
GuardSwitch™ Series 100
Non-Contact Interlock/Position Switch
129
129-2N-06(J) 129-2N-12(J) 129-3N-12(J) 129-6N-06(J) 129-6N-12(J) 129-7N-06(J) 129-7N-12(J) 129-9N-06(J) 129-9N-12(J)
129-6N-06(J)(D6) 129-6N-12(J)(D6) 129-6N-14(J)(D6) 129-6N-06(J)(DG) 129-6N-12(J)(DG) 129-6N-20(J)(DG) 129-_________ Actuator_____
Dimensions
2.76''
7.0cm
0.47''
1.19cm
0.08''
Figure 1
0.20cm
Switch Actuator
Figure 2
Barrel Switch Mounting Configurations
Three configurations are appropriate for recessed interlock applications. Moving the actuator parallel to the switch can result in on/off/on signal if the actuator passes by the switch rather than coming to rest in proximity to it. This is NOT a recommended configuration for interlock/position applications. The "T" configuration results in non-actuation.
End-to-End Side-by-Side
OK OK NO
M12 x 1
sensing
faces
1.40cm
0.63''
1.60cm
Perpendicular
OK
0.55''
“T”
Installation
1. Using the following guidelines, determine a suitable mounting location:
• The switch and actuator must be within the listed sense range. See Ordering/ Electrical Specifications.
• The sense ranges are based on switch and actuator aligned so the sensing surfaces are face to face. (See Figure 1.)
Important: When mounting in proximity to ferrous material (steel), the sense range can be reduced 50% minimum depending on the shape and type of material. Test the switch in specific applications to determine the actual sense range.
•When mounting on a ferrous material (steel), a 1/4" nonferrous (plastic or aluminum) spacer may be used under the actuator and switch to restore most of the lost gap.
•When mounting on a hinged gate or door, mount the switch and actuator at least 6" away from the hinges to achieve the maximum movement.
• The switch and actuator must move in one of the approved directions. See Figure 2.
• The actuator can be mounted at a 90° rotation to the switch.
•Do not mount for parallel actuation. An on-off-on signal may result when the actuator passes by the switch.
2. Mount the switch on the stationary frame of the machine and connect the electrical
P/N 13140 • REV C01 • REB 21FEB13
wiring. When mounting the switch on an ungrounded machine, connect the ground lead to one of the mounting screws.
3. Mount the actuator on the movable guard, door, or gate.
4. Slightly over-drill holes for easy insertion. The switch and actuator should easily slide or screw into the predrilled holes – DO NOT force or hammer. This may damage switch.
Wire Color Code
Black COM
File E 122942 LR89176
White N.O.
Red N.C.
General Specifications
Enclosure Stainless Steel Threaded Barrel
with 2 Panel Nuts
Dimensions M12 dia. x 1 Thread x 70mm Long
Temperature Range -40°F to 180°F (-40°C to 80°C)
Environmental Hermetically Sealed Contact Switch
Sealed in Polyurethane
NEMA Rating 1, 2, 3, 4X, 5, 6, 12
Protection Class IP 67
Response Time 1 msec
Life Cycles 100,000 Under Full Load;
Up to 200,000,000 Under Dry Circuit
Lead Types/O.D. 22/2 or 22/3 Flying Leads (V)/0.05" (0.13cm)
22/2 Jacketed (J)/0.16" (0.40cm)
22/3 Jacketed (J)/0.164" (0.41cm)
22/4 Jacketed (J)/0.187" (0.47cm)
18/2 Jacketed (J)/0.24" (0.62cm)
UL/CSA All Models