Edwards 125 Class LED Beacons are UL and cUL listed
signaling appliances rated for NEMA 4X applications. Two
versions of 125 Class Standard LED Beacons are available:
Flashing 65 FPM (125LEDF) and Steady-On (125LEDS).
Both versions can be either surface or conduit mounted.
A protective wire guard, Cat. No. 125GRD, is available.
Electrical Specications
GRAY BASE BLACK BASE
Catalog Number Catalog Number Voltage Current
Flashing LED
125LEDF*24D 125LEDF*24DB 24V DC 0.060A
125LEDF*120A 125LEDF*120AB 120V AC 50/60 Hz 0.097A
Steady-On LED
125LEDS*24D 125LEDS*24DB 24V DC 0.060A
125LEDS*120A 125LEDS*120AB 120V AC 50/60 Hz 0.097A
*Letter in this position indicates lens/LED color:
A - Amber, B - Blue, G - Green, R - Red
Mechanical Specications
Outdoor Locations
Temperature Ratings ...........-31F to +150F (-35C to +66C)
Installation
WARNING
To prevent electrical shock, ensure that
power is turned off before installing the
signal.
Conduit Mounting (Figure 1)
3. Thread the conduit onto the base of the signal.
4. Turn on power and verify that the signal operates
properly.
Panel Mounting (Figure 2)
WARNINGS
To avoid risk of injury, install lens before
energizing the unit.
To avoid the risk of injury, do not remove or
insert lamp when unit is energized.
Note: When panel mounting the beacon, the surface and
construction details of the panel must be taken into
consideration in order to ensure that the integrity
of the outdoor, NEMA 4X rating is fully maintained.
Installer should evaluate.
1. Place the mounting gasket (supplied) over the hole in
the panel and route the signal wires through the gasket
and the hole in the panel.
2. Insert the base through the hole in the panel and screw
the locking nut (supplied), with the raised locking edge
facing the mounting surface, onto the base to secure the
beacon.
3. Wire the beacon as follows:
a. For AC models, use wire nuts (not supplied) and
connect the signal's black and white wire leads to the
power source wires as shown in Figure 2. Polarity
is not relevant.
b. For DC models, connect the signal's red wire to the
positive power source wire and connect the signal's
black wire to the negative power source wire using
wire nuts (not supplied). Polarity must be observed.
Refer to Figure 2.
1. Thread the 18" (457 mm) signal wire leads through either
1/2" or 3/4" conduit into an approved conduit outlet box.
(Product is supplied with a double threaded - 1/2" internal
and 3/4" external - conduit hub.)
2. Wire the beacon as follows:
a. For AC models, use wire nuts (not supplied) and
connect the signal's black and white wire leads to
the power source wires as shown in Figure 1.
b. For DC models, connect the signal's red wire to the
positive power source wire and connect the signal's
black wire to the negative power source wire using
wire nuts (not supplied). Polarity must be observed.
Refer to Figure 1.
http://www.edwardssignaling.com Phone: (800) 336-4206 Fax: (800) 454-2363
4. Turn on power and verify that the signal operates
properly.
P/N 3101756 ISSUE 3
© 2010
Maintenance
WARNINGS
To avoid risk of injury, install lens before
energizing the unit.
To avoid the risk of injury, do not start any
maintenance when unit is energized.
Cleaning
Disconnect power before cleaning. The module lens exterior
surfaces should be periodically cleaned with a soft clean cloth
using water and a mild detergent to maintain optimum light
visibility.
Figure 1. Conduit Mounting (3/4" Shown)
125 Class
Visual Indicator
3/4” NPT external (shown)
1/2” NPT internal
conduit (not supplied)
18” Wire Leads
DC units; Red positive (+)
AC units; Black Hot
DC units; Black negative (-)
AC units; White neutral
Wire nuts
(not supplied)
Power Source
Wires
Locking Nut -
1.3625" OD
(supplied)
Control panel
(enclosure)
Figure 2. Panel Mounting
125 Class
Visual Indicator
Gasket
(supplied)
18” Wire Leads
Wire Nuts
(Not Supplied)
Power Source
Wires
Table 1. Replacement Parts
GRAY BASE BLACK BASE
Catalog Number Catalog Number
Replacement
Lens Replacement Lamp
Flashing LED
125LEDF*24D 125LEDF*24DB
125LEDF*120A 125LEDF*120AB
125L*
The 100,000 hour** LED light
source is permanently installed.
Steady-On LED
125LEDS*24D 125LEDS*24DB
125LEDS*120A 125LEDS*120AB
*Letter in this position indicates lens color: A - Amber, B - Blue, G - Green, R - Red
**Based on LED manufacturer's projections.
125L*
The 100,000 hour** LED light
source is permanently installed.