Edwards Signaling 116EXMSIN Series Catalog Page

VISUAL SIGNALS
FEATURES
®
AdaptaBeacon Explosionproof Steady-On Lights
Marine Rated
116EXMSIN Series
> Bracket, ceiling, pendant or
stanchion mount
> High impact glass dome, dome
guard included
> 40W halogen bulb or 25W
incandescent bulb
> Factory sealed - no external seals
required
> Quick connect - threads onto
mounting module for easy installation
> Shock absorbing receptacle
> Easy to assemble & relamp
> Gaskets seal out dirt & moisture
> Epoxy powder coat for corrosion
resistance
AGENCY APPROVALS
Edwards Explosionproof AdaptaBeacon Steady-On Lights are
designed for installation in hazardous location environments. Rigid
specifications and state-of-the-art technology provide for high visual
output and low maintenance.
installations. Models are available for pendant, wall, ceiling and
stanchion mounting.
Typical industrial and commercial applications include: food
processing plants, refineries, mines, tankers, laboratories, sewage
treatment plants, off shore oil rigs, water and filtration plants, and
chemical plants.
FAMILY TREE
Stanchion
116EX-S
Pendant
116EX-P
1 3/4" Hub
3/4" Conduit Entry
Ceiling/Wall
116EX-C
> UL 1638 and 1203 Listed
> cUL Listed C22.2 No. 205
> NEMA Type 3R & Type 4X Rated
> Marine UL Listed Category UXUB
> Marine UL 1598A Listed
> UL Listed Class I, Div. 1 & 2
D-04A
3-XX
Ceiling/Wall
116EX-C
1 3/4" Hubs
(3) 3/4" Conduit
Entries
Wall Bracket
Elbow
116EX-B
1 3/4" Hub
116EXMSIN Series
© Copyright 2006 Edwards
TECHNICAL INFORMATION
VISUAL SIGNALS
Stanchion
Mount
Wall
Mount
16 13/16"
1 1/4"
16 1/16"
13 1/4"
1 1/4"
conduit
25 deg.
12 9/16"
9 7/16" 1"
12 3/4"
13 1/2"
6 3/4"
4"
4"
5/16"
MOUNTING MODULES
Cat. No. Description
116EX-B
Wall bracket mounting elbow
116EX-C Ceiling/wall mounting module 116EX-P Pendant mounting module
116EX-S Stanchion mounting module
4"
6 3/4"
4"
7 1/4"
Pendant
Mount
Ceiling
Mount
1"
13"
13 3/4"
12"
12 3/4"
7 1/4"
Electrical Replacement Replacement Replacement Optional Replacement Peak
Cat. No. Rating Circuit Inner Lens* Dome Dome Guard Bulb Candela
116EXMSINHA-N5 120V 50/60 Hz
116SINH-N5-SA 116-RIN-LA 116-Globe 116-GRD 50LMP-40WH 3,328
116EXMSINHB-N5 0.1 Amp 116-RIN-LB 25,000 hrs.** 116EXMSINHC-N5 116-RIN-LC
116EXMSINHG-N5 116-RIN-LG 116EXMSINHM-N5 116-RIN-LM
116EXMSINHR-N5 116-RIN-LR
*A - Amber, B - Blue, C - Clear, G - Green, M - Magenta, R - Red ** Projected life based on manufacturer's calculated lamp life.
HAZARDOUS LOCATION LISTINGS
Operating Temperature
Ambient Supply Wire Class I, Div. 2 Class I, Div. 1 & 2 Class II & III, Div. 1 Class II & III, Div. 2
Temp. Temp. Marking Groups A, B Groups C, D Groups E, F, G Group G
40°C 75°C T1 (450°C) T6 (85°C) T4A (120°C) T4A (120 °C) 55°C 90°C T1 (450°C) T5 (100°C) T4 (135°C) T4 (135 °C) 65°C 105°C T1 (450°C) T5 (100°C) T4 (135°C) T4 (135 °C)
© Copyright 2006 Edwards
D-04A
3-XX