VISUAL SIGNALS
FEATURES
®
AdaptaBeacon
Explosionproof
Rotating Lights
Marine Rated
116EXMRIN Series
> Bracket, ceiling, pendant or
stanchion mount
> High impact glass dome, dome
guard included
> 40W halogen bulb or 25W
incandescent bulb
> 75 rotations per minute
> Factory sealed - no external seals
required
> Quick connect - threads onto
mounting module for easy
installation
> Shock absorbing receptacle
> Easy to assemble & relamp
> Gaskets seal out dirt & moisture
> Epoxy powder coat for corrosion
resistance
Edwards Explosionproof AdaptaBeacon Rotating Lights are
designed for installation in hazardous location environments. Rigid
specifications and state-of-the-art technology provide for high visual
output and low maintenance.
The units are UL Listed for Type 3R, Type 4X and marine
installations. Models are available for pendant, wall, ceiling and
stanchion mounting.
Typical industrial and commercial applications include: food
processing plants, refineries, mines, tankers, laboratories, sewage
treatment plants, off shore oil rigs, water and filtration plants, and
chemical plants.
FAMILY TREE
Stanchion
116EX-S
Pendant
116EX-P
1 3/4" Hub
3/4" Conduit Entry
Ceiling/Wall
116EX-C
AGENCY APPROVALS
> UL 1638 and 1203 Listed
> cUL Listed C22.2 No. 205
> NEMA Type 3R & Type 4X Rated
> Marine UL 595 Category UXUB
> Marine UL 1598A Listed
> UL Listed Class I, Div. 1 & 2
D-04A
3-XX
Ceiling/Wall
116EX-C
1 3/4" Hubs
(3) 3/4" Conduit
Entries
Wall Bracket
Elbow
116EX-B
1 3/4" Hub
116EXMRIN Series
© Copyright 2006 Edwards
TECHNICAL INFORMATION
VISUAL SIGNALS
Stanchion
Mount
Wall
Mount
16 13/16"
1 1/4"
16 1/16"
13 1/4"
1 1/4"
conduit
25 deg.
12 9/16"
9 7/16" 1"
12 3/4"
13 1/2"
6 3/4"
4"
4"
5/16"
MOUNTING MODULES
Cat. No. Description
116EX-B
Wall bracket mounting elbow
116EX-C Ceiling/wall mounting module
116EX-P Pendant mounting module
116EX-S Stanchion mounting module
4"
6 3/4"
4"
7 1/4"
Pendant
Mount
Ceiling
Mount
1"
13"
13 3/4"
12"
12 3/4"
7 1/4"
Cat. No. Rating Rotator Assy Inner Lens* Dome Dome Guard Bulb Candela
Electrical Replacement Replacement Replacement Optional Replacement Peak
116EXMRINHR-N5 120V 50/60 Hz 116RINH-N5-SA 116-RIN-LR 116-Globe 116-GRD 50LMP-40WH
3,328
116EXMRINHA-N5 0.42 Amp 116-RIN-LA 25,000 hrs.**
116EXMRINHB-N5 116-RIN-LB
116EXMRINHG-N5 116-RIN-LG
116EXMRINHM-N5 116-RIN-LM
116EXMRINHC-N5 116-RIN-LC
*A - Amber, B - Blue, C - Clear, G - Green, M - Magenta, R - Red
** Projected life based on manufacturer's calculated lamp life.
HAZARDOUS LOCATION LISTINGS
Operating Temperature
Ambient Supply Wire Class I, Div. 2 Class I, Div. 1 & 2 Class II & III, Div. 1 Class II & III, Div. 2
Temp. Temp. Marking Groups A, B Groups C, D Groups E, F, G Group G
40°C 75°C T1 (450°C) T6 (85°C) T4A (120°C) T4A (120 °C)
55°C 90°C T1 (450°C) T5 (100°C) T4 (135°C) T4 (135 °C)
65°C 105°C T1 (450°C) T5 (100°C) T4 (135°C) T4 (135 °C)
© Copyright 2006 Edwards
D-04A
3-XX