Edwards Signaling 116DEXMRINH User Manual

Cheshire, CT 06410 203-699-3300 (Ph) 203-699-3365 (Cust. Serv. Fax) 203-699-3078 (Tech. Serv. Fax)
STANCHION
116EX-S 1 1/4" HUB
Installation Instructions for 116DEXMRINH Series
AdaptaBeacon® Supervised DC Rotating Lights for
CEILING
116EX-C 3/4" HUB
Figure 1. Mounting Options
Use in Hazardous Locations
PENDANT
116EX-P 3/4" HUB
116EX-C
116 SERIES HOUSING AND GLOBE
ASSEMBLY WITH GUARD
WALL
116EX-B 3/4" HUB
DescriptionDescription
Description
DescriptionDescription
The 116DEXMRINH AdaptaBeacon 24-28V DC rotating sig­naling appliances are heavy duty diode-polarized rotat­ing lights intended for use in general utility signaling (non­fire alarm) applications requiring electrical supervision of signaling circuit field wiring. The rotating assembly mo­tor driven at approximately 60 rpm. These devices are UL and cUL listed for use in Class I, Division 1, Group C and D, Class I, Division 2, Group C and D, Class II, Divisions 1 and 2, Group F and G, Class II, Division 1, Group E, and Class III Division 1 and 2 hazardous locations with operating tem­perature codes per following chart.
They are UL and cUL Listed as Type 3R, 4X, and Marine enclosures.
The rotating assembly is driven by a motor that revolves 75 times per minute.
The beacons are available with pendant, bracket, ceiling, or stanchion mounting modules. See Figure 1.
InstallationInstallation
Installation
InstallationInstallation
Install this unit in accordance with the applicable require­ments in the latest edition of the National Electrical Code and Canadian Electrical Code.
mm) NPT threaded conduit (not supplied) to the box. Install the unit on the conduit. Proceed to step 2.
b. Ceiling Mount Models (Figure 3): Mount the
catalog number 116EX-C, ceiling/wall mounting module, using appropriate hardware (not supplied) suitable for the mounting surface. Proceed to step
2.
c. Bracket Mount Models (Figure 4): Install the
catalog number 116EX-C ceiling/wall mounting module using appropriate hardware (not supplied) for the mounting surface. Install the catalog number 116EX-B wall mounting elbow to the wall box. Run the unit's wiring through the elbow to the wall box. Proceed to step 2.
d. Stanchion Mount Models (Figure 5): Install the
catalog number 116EX-S, stanchion mounting module, to the main housing. Run the unit's wires through the 1 1/4" conduit to the appropriate junction box. Install the unit on the conduit. Proceed to step 2.
2. Connect field earth ground wire to ground screw or earth ground via conduit system.
3. Wire the unit in accordance with Figure 6. See Table 2 for required supply wire temperature ratings.
WARNING
To reduce the risks of ignition of hazardous atmo­spheres and shock, do not apply power to the unit until installation has been completed and unit is tightly assembled and secured.
1. Mount using the following applicable method. a. Pendant Mount Models (Figure 2): Install the
catalog number 116EX-P, pendant mounting module, to the main housing. Install explosion­proof hanger box (not supplied). Secure 3/4" (19
4. As appropriate, install the fixture on the mounting module.
WARNING
To reduce the risk of ignition of hazardous atmo­spheres and shock, keep assembly tightly closed when circuits are energized.
5. Apply power to the unit and ensure proper function.
P/N 3100761 ISSUE 1 © 2004
6 3/4"
1/4"
1 1/4"
Conduit
13 1/4"
12 3/4"
13 1/2"
4"
4"
12"
12 3/4"
5/16"
1"
13"
13 3/4"
7 1/4"
7 1/4"
Figure 2. Detail of Pendant Mounting Figure 3. Detail of Ceiling Mounting
12 9/16"
9 7/16"
16 1/16"
16 13/16"
6 3/4"
1"
4"
4"
5/16"
Figure 4. Detail of Wall Bracket Mounting Figure 5. Detail of Stanchion Mounting
NOTE: DC polarity of circuit shown in supervisory state (signal inactive). Circuit polarity to reverse to activate signal. Electrical supervision requires wire run to be broken at each device. Device for constant input voltage. Do not connect to “coded” or pulsating voltage.
(-)
(+)
(-)
(+)
White
Black
(-)
From Power Source
or
Previous Signaling Device
Series
116DEX
White
Black
Series
116DEX
(+)
White
Black
(-)
(+)
White
Black
(-)
KEY:
Light symbol -
Wire nut symbol -
End-of-Line Resistor, when required with supervised system
(+)
NOTE: For use without field wire supervision installer can tie the two white leads together and tie the two
black leads together .
P/N 3100761 ISSUE 1
Figure 6. Wiring Diagram
Loading...