Edwards Signaling 116 Class Catalog Page

116 Class LED Beacon
Explosionproof
The 116 Class LED Beacon is designed for use in explosionproof and hazardous location applications such as oil platforms, refineries, granaries and chemical plants. UL and cUL listed for use in Class 1, Division 1 and 2 applications, this beacon is designed for areas requiring high visibility and notification as well as low maintenance. The long life LEDs reduce maintenance requirements by up to 90% when compared to a xenon strobe tube. The LED light emits a 360-degree beam of light with 13 user selectable flash patterns in addition to a steady-on mode.
These beacons are UL and cUL listed for outdoor use as NEMA Type 3R, 4X, and Marine Rated enclosures. Mounting options are available (ordered separately) for ceiling, wall, pendant and stanchion mounts. The unit is supplied with a guard installed over the clear dome for additional protection against impact.
116 Class LED Beacon Features
Five lens colors Four mounting options: ceiling, wall, pendant
Steady-on and 13 other user selectable flash patterns Three operating voltage ranges:
Enclosures
– Type 3R – Type 4X – Marine Rated
or stanchion
– 24V AC/DC – 120-240V AC – 125-250V DC
LED
BRIGHTEST
EX-PROOF
HAZ-LOC
3R 4X
ENCLOSURE
AC
DC
AC/DC
Data Sheet ES001-2005 Issue 1
Not to be used for installation purposes.
Page 1 of 4
116 Class LED Beacon
Description
Explosionproof LED Light with user selectable flash patterns
*For most LED beacons, the LED color and lens color are the same. White LEDs are used with a clear inner lens for the White model..
Cat. No.
116EXMLEDA-Y6
116EXMLEDB-Y6
116EXMLEDW-Y6
116EXMLEDG-Y6
116EXMLEDR-Y6
116EXMLEDA-AQ
116EXMLEDB-AQ
116EXMLEDG-AQ
116EXMLEDR-AQ
116EXMLEDW-AQ
Operating Voltage Current LED/Lens Colors Flash Rate
120-240V 50/60 Hz
125-250V DC
120-240V 50/60 Hz
125-250V DC
120-240V 50/60 Hz
125-250V DC
120-240V 50/60 Hz
125-250V DC
120-240V 50/60 Hz
125-250V DC
24V AC/DC
24V AC/DC
24V AC/DC
24V AC/DC
24V AC/DC
0.215A
0.176A
0.215A
0.176A
0.215A
0.176A
0.215A
0.176A
0.215A
0.176A
1.18A AC
0.79A DC
1.18A AC
0.79A DC
1.18A AC
0.79A DC
1.18A AC
0.79A DC
1.18A AC
0.79A DC
Accessories
Description
Wall Bracket Mounting Elbow
Ceiling/Wall Mounting Module
Pendant Mounting Module
Stanchion Mounting Module
*Note: Wall mount requires both 116EX-B and 116EX-C.
Cat. No.
116EX-B* N/A
116EX-C 3/4" NPT
116EX-P 3/4" NPT
116EX-S 1 1/4" NPT
Conduit Size
Amber
Blue
White (Clear)*
Green
Red
Amber
Blue
Green
Red
White
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Adjustable
See Flash Mode Selection
Hazardous Location Ratings
Operating Temperature
116 Class LED Beacon
Ambient
Temp.
40°C 75°C T4 (135°C) T6 (85°C) T4A (120°C) T4A (120°C) T4A (120°C)
55
65
Supply Wire
Temp. Marking
°
C 90°C T3C (160°C) T6 (85°C) T4 (135°C) T4 (135°C) T4 (135°C)
°
C 105°C T3C (160°C) T6 (85°C) T4 (135°C) T4 (135°C) T4 (135°C)
Class I, Div. 2
Groups A, B
Class I, Div. 1 & 2
Groups C, D
Class II, Div. 1
Groups E, F, G
Class II, Div. 2
Groups F, G
Class III,
Div. 1 & 2
Flash Mode Selection
Pattern Description
Steady-On Steady OFF OFF OFF OFF
Multiburst 1 7 Bursts - Delay- Repeat OFF OFF OFF ON
Multiburst 2 5 Bursts - Delay - Repeat OFF OFF ON OFF
Multiburst 3 10 Bursts - 3 Bursts - Repeat OFF OFF ON ON
Multiburst 4 8 Bursts - delay w/slight illumination - Repeat OFF ON OFF OFF
Flash 1 65 FPM 10% Duty Cycle OFF ON OFF ON
Flash 2 65 FPM 25% Duty Cycle OFF ON ON OFF
Flash 3 65 FPM 50% Duty Cycle OFF ON ON ON
Flash 4 65 FPM 75% Duty Cycle ON OFF OFF OFF
Flash 5 80 FPM 10% Duty Cycle ON OFF OFF ON
Flash 6 80 FPM 25% Duty Cycle ON OFF ON OFF
Flash 7 80 FPM 50% Duty Cycle ON OFF ON ON
Flash 8 80 FPM 75% Duty Cycle ON ON OFF OFF
Ramper Ramps up and then ramps down ON ON OFF ON
Listed
Switch
S4
Switch
S3
Switch
S2
Switch
S1
Data Sheet ES001-2005 Issue 1