Edwards Signaling 107DDV2 Series Catalog Page

VISUAL SIGNALS
FEATURES
> Bracket, ceiling or pendant mount
> Diode polarized for use in
electrically supervised circuits
> High impact glass dome
> Dome guard (optional)
> 65 flashes per minute
AdaptaBeacon
®
Division 2 Strobes
Diode Polarized NEMA Type 3R & 4 Rated
107DDV2
Edwards AdaptaBeacon Strobe Lights are designed for installation
in Division 2 environments. Rigid specifications and state-of-the-art
technology provide for high visual output and low maintenance. The
units are UL Listed for Type 3R and Type 4 installations. Models are
Designed for hazardous location installation on 3/4" (19mm)
conduit. May be mounted in any orientation.
(†)
ST-G1 Series
AGENCY APPROVALS
> UL 1638 and 1604 Listed
> cUL Listed C22.2 No. 205
> NEMA Type 3R & Type 4 Rated
> UL Listed Class I, Div. 2
Typical industrial and commercial applications include: food
processing plants, refineries, mines, tankers, laboratories, sewage
treatment plants, water and filtration plants, and chemical plants.
D-04
3-88
† Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount
© Copyright 2004 Edwards
TECHNICAL INFORMATION
10 1/2"
(267mm)
4"
(102mm)
VISUAL SIGNALS
11 3/8"
(289mm)
(276mm)
10 7/8"
10 1/8"
(260mm)
9 3/4"
(248mm)
7"
(178mm)
(260mm)
10 1/4"
9 7/8"
(251mm)
7"
(172mm)
Lens Electrical Replacement Replacement Optional Replacement Peak
Cat. No. Color Mounting Rating Dome Inner Lens Dome Guard Strobe Tube Candlepower
107DDV2BSTR-G1 Red Bracket 24V DC EDVPGL1HR 96-LR
EDVPGU1 92-ST 800,000 107DDV2BSTA-G1 Amber 1.4 Amp 96-LA 3,000 hr* 107DDV2BSTB-G1 Blue 96-LB 107DDV2BSTG-G1 Green 96-LG 107DDV2BSTM-G1 Magenta 96-LM 107DDV2BSTC-G1 Clear 96-LC
107DDV2CSTR-G1 Red Ceiling 24V DC EDVPGL1HR 96-LR EDVPGU1 92-ST 800,000 107DDV2CSTA-G1 Amber 1.4 Amp 96-LA 3,000 hr* 107DDV2CSTB-G1 Blue 96-LB 107DDV2CSTG-G1 Green 96-LG 107DDV2CSTM-G1 Magenta 96-LM 107DDV2CSTC-G1 Clear 96-LC
107DDV2PSTR-G1 Red Pendant 24V DC EDVPGL1HR 96-LR EDVPGU1 92-ST 800,000 107DDV2PSTA-G1 Amber 1.4 Amp 96-LA 3,000 hr* 107DDV2PSTB-G1 Blue 96-LB 107DDV2PSTG-G1 Green 96-LG 107DDV2PSTM-G1 Magenta 96-LM 107DDV2PSTC-G1 Clear 96-LC
*Calculated at operating power to 75% efficiency.
HAZARDOUS LOCATION LISTINGS
Class Division Group Ambient Temperature Operating Temperature Code
I 2 A,B,C,D 104F (40C) T2 (300C, 572F)
II** 1 and 2** 104F (40C) T4A (120C, 248F) III** 1 and 2** 131F (55C) T4 (135C, 275F)
**Pendant mount models only. Pendant mount models are also listed for use in Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G and Class III, Division 1 and 2 hazardous locations.
© Copyright 2004 Edwards
131F (55C) T1 (450C, 842F) 149F (65C) T1 (450C, 842F)
149F (65C) T3C (160C, 320F)
D-04
3-89