Description
Installation Instructions for 104 Series AdaptaBeacon
Modules in NEMA 4X Enclosures
®
The 104 Series AdaptaBeacon is a UL and cUL listed signaling
appliance in a NEMA 4X and IP65 rated enclosure. CE Marked.
The modules can be panel mounted or conduit mounted.
AdaptaBeacon modules are available in Flashing LED
(104FLED), Steady-On LED (104SLED), Flashing Halogen
(104FINH), Steady-On Halogen (104SINH) or Flashing Strobe
(104ST). The maximum capacitor operating temperature (Tc) is
185°F (85°C).
The modules are available in a variety of colors as listed in
Table 1.
Catalog Illumination
Number Voltage Current Source
104FLED(*)-G1 24V DC 0.062 A 28 LED Cluster
104FLED(*)-N5 120V 50/60 Hz 0.022 A 28 LED Cluster
104SLED(*)-G1 24V DC 0.062 A 28 LED Cluster
104SLED(*)-N5 120V 50/60 Hz 0.022 A 28 LED Cluster
104FINH(*)-G1 24V DC 0.77 A 9W Halogen Bulb
104FINH(*)-G5 24V 50/60 Hz 0.77 A 9W Halogen Bulb
104FINH(*)-N5 120V 50/60 Hz 0.25 A 12W Halogen Bulb
104SINH(*)-G1 24V DC 0.77 A 9W Halogen Bulb
104SINH(*)-G5 24V 50/60 Hz 0.77 A 9W Halogen Bulb
104SINH(*)-N5 120V 50/60 Hz 0.25 A 12W Halogen Bulb
104ST(*)-N5 120V 50/60 Hz 0.12 A Xenon Strobe Tube
*Letter in this position signifies color of the lens. For available colors, see
Table 1.
3. Thread the conduit onto the base of the signal.
4. Turn on power and verify that the signal operates properly.
Panel Mounting (Figure 2)
Note: The integrity of the outdoor, NEMA 4X, and IP65 rating
on the panel assembly at the interface with the 104 Series
AdaptaBeacon relies on the construction and configuration details of the mounting surface. Installer should evaluate.
1. Place the mounting gasket (supplied) over the hole in the
2. Insert the base through the hole in the panel and screw the
3. Wire the beacon as follows:
Specifications
WARNING
To prevent electrical shock, ensure that power is
turned off before installing the signal.
4. Turn on power and verify that the signal operates properly.
WARNINGS
To avoid risk of injury, install lens before energizing
the unit.
To avoid the risk of injury, do not remove or insert
lamp when unit is ener gized.
panel and route the signal wires through the gasket and the
hole in the panel.
locking nut (supplied), with the raised locking edge facing
the mounting surface, onto the base to secure the beacon.
a. For AC models, use wire nuts (not supplied) and connect
the signal's black and white wire leads to the power source
wires as shown in Figure 2. Polarity is not relevant.
b. For DC models, connect the signal's red wire to the
positive power source wire and connect the signal's black
wire to the negative power source wire using wire nuts
(not supplied). Polarity must be observed. Refer to
Figure 2.
Installation
Conduit Mounting (Figure 1)
1. Thread the 18" (45.7 cm) signal wire leads through either
1/2" (13mm) or 3/4" (19 mm) conduit into an approved
conduit outlet box. (Product is supplied with a double
threaded - 1/2" (13mm) internal and 3/4" (19mm) external conduit hub.)
2. Wire the beacon as follows:
a. For AC models, use wire nuts (not supplied) and connect
the signal's black and white wire leads to the power source
wires as shown in Figure 1. Polarity is not relevant.
b. For DC models, connect the signal's red wire to the
positive power source wire and connect the signal's black
wire to the negative power source wire using wire nuts
(not supplied). Polarity must be observed. Refer to
Figure 1.
P-047550-1848 ISSUE 6 © 2003
Maintenance
b. Grasping the base of the new lamp or strobe tube, insert
in the socket.
WARNINGS
To avoid risk of injury, install lens before energizing
the unit.
To avoid the risk of injury, do not start any
maintenance when unit is ener gized.
To prevent electrical shock, disconnect all power
and wait five (5) minutes for stored energy in strobe
modules to dissipate before starting work on unit.
Cleaning
The module lens exterior surfaces should be periodically cleaned
with a soft clean cloth using water and a mild detergent to maintain optimum light visibility. Disconnect power before cleaning.
Lamp Replacement
1. Conduit Mounted Modules: Disconnect wiring and, if
necessary, unscrew base from conduit (Figure 1).
Panel Mounted Modules: Disconnect wiring and remove
locking nut securing the base to the panel (Figure 2).
2. Remove (4) screws securing the lens to the base from bottom
of base (Figure 3) and remove lens.
4. Replace lens on base and secure with (4) screws removed in
step 2.
3. Replace halogen lamp or strobe tube as follows (Figure 3):
a. Halogen Lamp: Grasping the base of the halogen lamp
(Do not touch actual halogen lamp envelope), push
the halogen lamp down while turning counterclockwise.
Then, pull the lamp directly upward to remove from the
socket.
Strobe Tube: Grasping the base of the strobe tube (Do
not touch actual strobe tube glass), pull directly upward
to remove the strobe tube from the socket.
Figure 1. Conduit Mounting (3/4" Shown)
P-047550-1848 ISSUE 6
Figure 2. Panel Mounting
Figure 3. Lamp Replacement