Installation Instructions for Triliptical
TM
Cheshire, CT 06410 203-699-3300 (Ph)
203-699-3365 (Cust. Serv. Fax)
203-699-3078 (Tech. Serv. Fax)
Stackable Status Indicator Tone Modules
Description
The Edwards Triliptical Stackable Status Indicator is a unique audible-visual signaling device that can contain up to 5 light modules
and either a single or multiple tone module in a single "stack."
All components of the Triliptical Stackable Status Indicator are UL
and cUL listed subassemblies. The units, when assembled, are UL
and cUL listed for indoor and outdoor applications. The enclosures are NEMA 3R, 4X, and IP65 rated. See Table 1 for specifications.
The indicator bases are available in three models. Two models
feature a shorter base that is used when a lower profile is desired;
the other model features a larger base with a terminal block designed to function as a junction box for use with an optional horn
assembly.
Installation
Installation must be in accordance with local codes.
1. Mount the base using one of the following methods:
NOTE: For NEMA 3R, 4X, and outdoor applications, it is
recommended that the unit be conduit mounted vertically
facing up.
a. Cat. No. 102TBS Pull field wiring through conduit entrance
hole. Install base on 3/4" (19 mm) conduit (not supplied).
2. Connect field wiring.
a. Cat. No. 102TBS Connect field wiring to the terminal block
as shown in Figure 1.
b. Connect additional field wiring to the terminal block
mounted on the signal assembly as shown in Figure 2.
NOTE: The tone module may be wired to sound independently or in
conjunction with a light signal.
(1) To sound tone independently, connect to separate
hot lead.
WARNING
To prevent electrical shock, do not connect power
until instructed to do so.
Table 1. Specifications
Catalog No. Voltage Current (A)
102SIGST-G1 24V DC 0.05
102SIGST-N5 120V AC 0.07
102SIGMT-G1 24V DC 0.05
102SIGMT-N5 120V AC 0.07
Table 2. Switch Settings
Tone 1 2 3
Stutter beep OFF OFF OFF
Hi / Lo ON OFF O FF
3 Pulse Horn OF F ON OFF
Continuous OFF OFF ON
Yeow ON ON OFF
Fast Whoop ON OFF ON
Rapid Siren OFF ON ON
Beep ON ON ON
*ON is in the "UP" position (see Figure 3).
(2) To sound tone with a particular light, connect tone
module hot terminal to selected light terminal on Cat.
102TBS terminal block.
3. If using the multi-tone module, Cat. No. 102SIGMT, set the
selected tone. See Table 2 and Figure 3.
NOTE: For further installation details, see the instructions supplied
with the lens modules, P/N 3100700, with the base, P/N
3100669, or with the light sources, P/N 3100701.
Switch Settings*
P/N 3100702 ISSUE 1 © 2003
NEUTRAL/COMMON
MODULE 1
MODULE 2
BOTTOM
MODULE 3
Figure 1. Wiring Cat. No. 102TBS
TERMINAL
BLOCK
MODULE 4
MODULE 5
TO NEUTRAL
ON CAT. 102TBS
TERMINAL BLOCK
NH
SEPARATE HOT LEAD OR
CONNECTED TO APPROPRIATE
LIGHT MODULE TERMINAL ON
CAT. 102TBS TERMINAL BLOCK
Figure 2. Wiring Cat. No. 102SIG*T with Optional
Tone Module
COM
VAC
120
ON
123
TONE SELECTI
DIPSWITCH
(SEE TABLE 2))
Figure 3. Cat. No. 102SIGMT PC Board (120V version shown)
P/N 3100702 ISSUE 1