102 Series Triliptical Stackable Beacon Lighting
System Light Sources Installation Sheet
b. Insert the appropriate light source into board grooves
at bottom of lens ensuring that the four prongs on the
PC board are aligned with the plug located in the back
of the lens assembly.
NOTE: When using LED light sources, ensure that the color
of the LED light source and the color of the lens assembly
match.
WARNING: To prevent leakage, ensure the magnifier ring on
the lens cover and the magnifier ring on the lens module are
aligned (Figure 1).
c. Place the lens module cover on the front of the lens
module and secure using two captive screws.
d. Repeat steps a through c for any remaining modules
(up to 5).
e. Once the last module has been assembled, place the
cap on top and secure the cap with the captive screw.
Description / Operation
The Edwards Triliptical Stackable Beacon Lighting System is a
unique audible-visual signaling device that can contain up to 5
light modules and either a single or multiple tone module in a
single "stack."
All components of the Triliptical Stackable Beacon Lighting
System are UL and cUL listed subassemblies. The units,
when assembled, are UL and cUL listed for indoor and outdoor
applications.
The enclosures are NEMA 3R, 4X, and IP65 rated. Each light
source module contains a removable cover to allow for easy
relamping. The light module cover features a molded-in gasket
for dust tight reliability.
Installation
WARNING: To prevent electrical shock, do not connect power
until instructed to do so.
Installation must be in accordance with local codes.
1. Assemble the stackable beacon lighting system (Figure 1).
a. Loosen captive screws and remove cover of affected
lens module.
2. Apply power to the unit and verify proper operation.
NOTE: For further installation details, see the instructions
supplied with the lens modules, P/N 3100700, or the
instructions supplied with the base, P/N 3100669.
Maintenance
WARNING: To prevent electrical shock, disconnect power to
all modules. Wait 5 minutes for stored energy in strobe
modules to dissipate before working on unit.
Light Source Replacement
1. Loosen captive screws and remove cover of affected lens
module.
2. Remove the light source assembly from the lens module.
3. Install new light source assembly ensuring that the four
prongs on the PC board are aligned with the plug located
in the back of the lens module.
WARNING: To prevent leakage, ensure the magnifier ring on
the lens cover and the magnifier ring on the lens module are
aligned (Figure 1).
4. Replace lens cover and secure using two captive screws.
© 2010 UTC Fire & Security. All rights reserved. 1 / 2 P/N 3100701 • REV 3 • ISS 09AUG10
Cleaning
The lens surfaces should be periodically dusted and cleaned
with a dry soft clean cloth to maintain optimum light visibility. If
necessary, the outside of the lens may be cleaned with water
and a mild detergent on a well rung-out, soft, clean cloth.
Figure 1: Assembling the stackable beacon lighting system
Specifications
Voltage 24 VDC (-G1) 120 VAC (-N5)
Current
Light Modules
102LS-SINH
102LS-SIN
102LS-FINH
102LS-FIN
102LS-ST
102LS-SLED
102LS-FLED
Replacement Lamp
102LS-SINH
102LS-SIN
102LS-FINH
102LS-FIN
*Currents shown are for a stackable indicator with 5 light modules.
**A non-halogen lamp, Ind. Trade 303, may be used in place of the
halogen lamp.
0.32 A
0.32 A
0.32 A
0.32 A
0.30 A
0.062 A
0.062 A
50LMP-9WH**
Ind. Trade 303
50LMP-9WH**
Ind. Trade 303
0.11 A
0.08 A
0.11 A
0.08 A
0.30 A
0.022 A
0.022 A
50LMP-12WH
50LMP-10W
50LMP-12WH
50LMP-10W
Table 1: Lamp Life (Hours)
Light Source Calculated* Projected**
102LS-SINH-G1 12,000 -102LS-SINH-N5 20,000 -102LS-SIN-G1 10,000 -102LS-SIN-N5 2,500 -102LS-FINH-G1 12,000 15,000
102LS-FINH-N5 20,000 25,000
102LS-FIN-G1 10,000 12,500
102LS-FIN-N5 2,500 3,000
102LS-ST-G1
102LS-ST-N5
102LS-SLED
102LS-FLED
*At nominal operating voltage.
**Projected lamp life based on manufacturer’s calculated lamp life @
65 fpm and 50% duty cycle.
***Strobe tube life @ operating power to 75% efficiency.
Table 2: Part numbers
Catalog Number Description
102LS-SINH-G1
102LS-SINH-N5
102LS-SIN-G1
102LS-SIN-N5
102LS-FINH-G1
102LS-FINH-N5
102LS-FIN-G1
102LS-FIN-N5
102LS-ST-G1
102LS-ST-N5
102LS-SLED**-G1
102LS-SLED**-N5
102LS-FLED**-G1
102LS-FLED**-N5
102MP-4
102MP-10
102MP-15
*Signifies lens module color (A – amber/orange, B – blue, C – clear, G
– green, R – red, Y – yellow)
**Signifies lens and LED module color (A – amber/orange, B – blue, G
– green, R – red). NOTE: LED light sources must be used with the
corresponding color lens module (e.g., a blue LED light source, 102LSSLEDB-G1, must be used with a blue lens, 102LM-B).
3,000*** --
100,000 --
Light module, steady-on, 9W halogen
Light module, steady-on, 12W halogen
Light module, steady-on, 10W incandescent
Light module, flashing, 9W halogen
Light module, flashing 12W halogen
Light module, flashing, 10W incandescent
Light module, 3 Joule strobe
Light module, steady-on LED
Light module, flashing LED
Optional Extension Pipe, 4 in.
Optional Extension Pipe, 10 in.
Optional Extension Pipe, 15 in.
Regulatory information
Edwards Signaling Edwards, A Division of UTC Fire & Security
Americas Corporation, Inc.
8985 Town Center Parkway, Bradenton, FL
34202, USA
2 / 2 P/N 3100701 • REV 3 • ISS 09AUG10
Contact information
For contact information, see www.edwardssignaling.com.