Edwards XDS35i-NGB, XDS35iC, XDS35iE, XDS35iCE, XDS35i Instruction Manual

...
Instruction Manual
XDS35i, XDS35iC, XDS35iE and XDS35iCE Scroll Pumps
A730-01-880
Issue L
Description Electrical Supply Item Number
XDS35i Scroll Pump (set to high volts} 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-YY-983
XDS35i Scroll Pump (set to low volts) 100-120 V, 200-230 V, 50/60 Hz - Set to 100 - 120 V A730-YY-986
XDS35iC Scroll Pump Chemical 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-06-938
XDS35i Scroll Pump (No Gas Ballast) 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-05-983
XDS35iE Scroll Pump Enhanced 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-03-983
XDS35iCE Scroll Pump Enhanced Chemical 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-08-983
XDS35iE Scroll Pump Enhanced (No Gas Ballast) 100-120 V, 200-230 V, 50/60 Hz - Set to 200 - 230 V A730-07-983
Original Instructions
This product has been manufactured under a quality management system certified to ISO 9001:2015.
P200-01-400-M
2006/42/EC
Machinery directive
2014/35/EU
Low voltage directive
2014/30/EU
Electromagnetic compatibility (EMC) directive
2014/34/EU
ATEX directive on use in potentially explosive atmospheres
II 3 G Ex h IIB T4 Gc Internal Atmospheres Only, Tech File ref 209
2011/65/EU
Restriction of certain hazardous substances (RoHS) directive
EN 1012-2:1996 +A1:2009
Compressors and vacuum pumps. Safety requirements. Vacuum pumps
EN 13463-1:2009
Non-electrical equipment for use in potentially explosive atmospheres. Basic method requirements
EN 13463-5:2011
Non-electrical equipment for use in potentially explosive atmospheres. Protection by constructional safety ‘c’
EN 61010-1:2010
Safety requirements for electrical equipment for measurement, control and laboratory use. General requirements
EN 61326-1:2013
Electrical equipment for measurement, control and laboratory use. EMC
Class A Emissions, Industrial Immunity
CSA-C22.2 No.61010-1-12
Safety requirements for electrical equipment for measurement, control and laboratory use –Part 1: General requirements
L61010-1 3rd Edition
Safety requirements for electrical equipment for measurement, control and laboratory use – Part 1: General requirements
Mr Ian Keech
Date and Place
Declaration of Conformity
Edwards Ltd, Innovation Drive, Burgess Hill, West Sussex, RH15 9TW, UK
The following products: XDS35i scroll pump, 100-120 V, 200-230 V, 1 ph, 50/60 Hz, set to high volts A730-YY-983 XDS35i scroll pump, 100-120 V, 200-230 V, 1 ph, 50/60 Hz, set to low volts A730-YY-986 XDS35i scroll pump, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-01-983 XDS35i scroll pump no gas ballast, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-05-983 XDS35iC scroll pump, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-06-983 XDS35iE scroll pump enhanced, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-03-983 XDS35iE scroll pump no gas ballast enhanced, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-07-983 XDS35iCE scroll pump enhanced, 100-120 V, 200-230 V, 1 ph, 50/60 Hz A730-08-983 XDS46i scroll pump, 100-120 V, 200-230 V, 50/60 Hz, single phase A731-01-983 XDS46iC scroll pump, 100-120 V, 200-230 V, 50/60 Hz, single phase A731-06-983 XDS100B scroll pump, 100-120V, 200-230V, 50/60Hz, single phase A732-01-983
where YY is represented by a two digit number between 01 and 99.
Is in conformity with the relevant requirements of European CE legislation:
Based on the relevant requirements of harmonised standards:
requirements. General requirements
The product also complies with the following:
This covers all product serial numbers from the date of this declaration onwards.
22.10.2018, Burgess Hill
Vice President Engineering, High Vacuum Division
This declaration is based on the requirements of EN ISO 17050-1 and the relevant directives.
P200-10-019 Issue D
Material Declaration
In accordance with the requirements of the Chinese regulatory requirement on the Ma nagement Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Order No. 32 (also known as ‘China RoHS2’) and SJ/T 11364 Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products:
Product Labels
Product Product Label Meaning
This product contains hazardous substances in at least one of the
All pumps in the
list below
Pump Type Pump Size
RV Pumps RV3,5,8,12, E Lab, nRVi EM Small Pumps E2M0.7, 1.5, E1M18, E2M18, 28, 30, nE2M40i nEXT Pumps nEXT 85, 240, 300, 400, Splitflow nXDS pumps nXDS 6, 10, 15, 20 EXT pumps EXT75DX XDS pumps XDS35, 46, 100 Diaphragm XDD 1, D lab Turbo Pump Carts T station, nEXPT, nEXT station
部件名称
Part name
铸铝
Cast Aluminium
铜管管件
Brass pipe Fittings
铜接头
Brass Connectors
2020
Lead
(Pb)
Mercury
X O O O O O
X O O O O O
X O O O O O
homogeneous materials used which are above the limit requirement in GB/T 26572 as detailed in the declaration table below. These parts can safely be used for the environmental protection use period as indicated.
材料成分声明
Materials Content Declaration
(Hg)
Cadmium
(Cd)
危险物
六价铬
Hexavalent
Chromium
(Cr VI)
多溴联苯
Polybrominated biphenyls (PBB)
Polybrominated diphenyl ethers
多溴二苯醚
(PBDE)
O 表示该有害物质在该部件的所有均质材料中的含量低于 GB/T 26572 标准规定的限量要求。 O: Indicates that the hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in GB/T 26572. X 表示该有害物质在该部件的至少一种均质材料中的含量超出 GB/T26572 标准规定的限量要求。 X: Indicates that the hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T26572.
NOTES: These products are EU RoHS compliant, the following Exemptions apply: 6(b) Lead as an alloying element in aluminium containing up to 0.4% by weight. 6(c) Copper alloy containing up to 4% lead by weight
Packaging Information
Pallet Over-shipper Protection Pieces Support Braces
NWNW
Recyclable Natural Wood Recyclable Cardboard Recyclable Polypropylene Recyclable Mild Steel
This page has been intentionally left blank.
A730-01-880 Issue L

Contents

Section Page
1 Introduction ....................................................................................... 1
1.1 Scope of this manual .................................................................................................... 1
1.2 ATEX directive implication ............................................................................................. 2
1.3 Description ................................................................................................................ 3
1.4 Gas ballast control ....................................................................................................... 4
1.5 Construction .............................................................................................................. 4
2 Technical data .................................................................................... 5
2.1 Operating and storage conditions ..................................................................................... 5
2.2 Performance .............................................................................................................. 5
2.2.1 General .................................................................................................................... 5
2.2.2 Performance characteristics ........................................................................................... 6
2.3 Mechanical data .......................................................................................................... 7
2.3.1 General .................................................................................................................... 7
2.4 Electrical data ............................................................................................................ 7
2.4.1 Electrical cables .........................................................................................................8
Contents
3 Installation ......................................................................................... 9
3.1 Safety ......................................................................................................................9
3.2 System design considerations ......................................................................................... 10
3.3 Unpack and inspect ..................................................................................................... 12
3.4 Locate the pump ........................................................................................................12
3.4.1 Mechanical fixing .......................................................................................................12
3.5 Electrical installation ..................................................................................................12
3.5.1 Check and configure the pump .......................................................................................12
3.5.2 Connect the pump to the electrical supply ......................................................................... 13
3.6 Inlet and outlet connections ..........................................................................................13
3.7 Leak test the system ...................................................................................................14
4 Operation ........................................................................................ 15
4.1 Use of gas ballast control (if fitted) .................................................................................15
4.1.1 Gas ballast control ...................................................................................................... 15
4.2 Start up procedure ..................................................................................................... 15
4.3 To achieve ultimate vacuum (if gas ballast fitted) ................................................................ 16
4.4 To pump condensable vapours (if gas ballast fitted) ..............................................................16
4.5 Implication of ATEX directive ......................................................................................... 16
4.5.1 Flammable/pyrophoric materials ....................................................................................16
4.5.2 Gas purges ...............................................................................................................16
4.6 Remote operation using 15-way D connector ...................................................................... 17
4.7 Shut down ................................................................................................................17
5 Maintenance ..................................................................................... 19
5.1 Safety information ...................................................................................................... 19
5.2 Maintenance plan .......................................................................................................20
5.3 Inspect and clean the inlet strainer ................................................................................. 20
5.4 Inspect and clean the gas ballast control (if fitted) ............................................................... 21
5.5 Clean the external fan cover ......................................................................................... 22
5.6 Replace the tip seals ...................................................................................................22
5.7 Test the motor condition ..............................................................................................23
5.8 Fault finding .............................................................................................................23
cg/8299/10/18
© Edwards Limited 2018. All rights reserved. Page i
A730-01-880 Issue L
Contents
5.8.1 The pump has failed to start or has stopped .......................................................................23
5.8.2 The pump has failed to achieve the required performance ...................................................... 23
5.8.3 The pump is noisy ....................................................................................................... 24
5.8.4 The pump surface temperature is high .............................................................................. 24
5.8.5 The pumping speed is poor or if pump down time is too long ...................................................24
6 Storage and disposal ........................................................................... 25
6.1 Storage ...................................................................................................................25
6.2 Disposal ...................................................................................................................25
7 Service and spares .............................................................................. 27
7.1 Introduction .............................................................................................................27
7.2 Service ....................................................................................................................27
7.3 Accessories ...............................................................................................................27
7.3.1 Electrical cables ........................................................................................................ 27
7.3.2 Silencer ................................................................................................................... 27
7.3.3 Gas ballast adaptor ..................................................................................................... 27
7.3.4 Solenoid operated pipeline valves ...................................................................................28
7.3.5 Service kits ..............................................................................................................28

Illustrations

Figure Page
1 General view ............................................................................................................. 3
2 Performance characteristics of XDS35i ............................................................................... 6
3 Performance characteristics of XDS35iE ............................................................................. 6
4 Installation drawing (dimensions in mm) ............................................................................11
5 Logic interface schematic .............................................................................................18
6 Inlet strainer assembly ................................................................................................. 21
7 Gas ballast control assembly ..........................................................................................22
Page ii © Edwards Limited 2018. All rights reserved.
A730-01-880 Issue L

Tables

Table Page
1 Operating and storage conditions ..................................................................................... 5
2 General characteristics ................................................................................................. 5
3 Performance characteristics ........................................................................................... 6
5 General mechanical data ............................................................................................... 7
6 Electrical data ............................................................................................................ 7
7 Recommended regional supply protection ........................................................................... 7
8 Recommended cordsets ................................................................................................. 8
9 Pin status on the logic interface connector ........................................................................18
10 Maintenance plan .......................................................................................................20
11 Solenoid operated pipeline valves ...................................................................................28

Associated publications

Publication title Publication number
Contents
Vacuum Pump and Vacuum System Safety P400-40-100
Tip Seal Replacement Kit Manual A730-01-840
By-pass Valves Exchange Manual A730-01-860
Trademark credits
Edwards and the Edwards logo are trademarks of Edwards Limited, Innovation Drive, Burgess Hill, West Sussex, RH15 9TW, UK.
© Edwards Limited 2018. All rights reserved. Page iii
A730-01-880 Issue L
This page has been intentionally left blank.
Page iv © Edwards Limited 2018. All rights reserved.
A730-01-880 Issue L
CAUTION
WARNING

1Introduction

1.1 Scope of this manual

This manual provides installation, operation and maintenance instructions for the Edwards XDS35i, XDS35iC, XDS35iE, and XDS35iCE scroll pumps. The pump must be used as specified in this manual. Read this manual before installing and operating the pump.
Important safety information is highlighted as WARNING and CAUTION instructions; these instructions must be obeyed. The use of WARNINGS and CAUTIONS is defined below.
Warnings are given where failure to observe the instruction could result in injury or death to people. The actual symbol shown varies according to the hazard.
Cautions are given where failure to observe the instruction could result in damage to the equipment, associated equipment and/or process.
Introduction
The units used throughout this manual conform to the SI international system of units of measurement.
The following Warning labels may be present on the pump and used throughout the product documentation:
Warning/Caution – An appropriate safety instruction should be followed or a caution to a potential hazard exists.
Warning – Dangerous Voltage. Indicates hazards arising from dangerous voltages.
Warning – Hot Surfaces. To indicate that the marked item can be hot and should not be touched without taking precautions.
Warning – Heavy Object. Indicates the potential risk of physical injury and requires suitable lifting equipment to move.
Warning - Use protective equipment. Indicates that appropriate protective equipment must be used.
© Edwards Limited 2018. All rights reserved. Page 1
A730-01-880 Issue L
Introduction

1.2 ATEX directive implication

This equipment is designed to meet the requirements of Group II Category 3 equipment in accordance with Directive 2014/34/EU of the European Parliament and the Council of 29th March 2014 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres. (The ATEX Directive)
The ATEX Category 3 applies in respect of potential ignition sources internal to the equipment. An ATEX Category has not been assigned in respect of potential ignition sources on the outside of the equipment as the equipment has not been designed for use where there is an external potentially explosive atmosphere.
There is no potential source of ignition within the pump during normal operation but there may be potential sources of ignition under conditions of foreseeable and rare malfunction as defined in the Directive. Accordingly, although the pump is designed to pump flammable materials and mixtures, operating procedures should ensure that under all normal and reasonably foreseeable conditions, these materials and mixtures are not within explosive limits. Category 3 is considered appropriate for the avoidance of ignition in the case of a rare malfunction which allows flammable materials or mixtures to pass through the pump whilst within their explosive limits.
Page 2 © Edwards Limited 2018. All rights reserved.
Figure 1 - General view
1. NW40 inlet port
2. Gas ballast control (not fitted on No Gas Ballast variant)
3. Cooling fan
4. NW25 exhaust port
5. Fan connector
6. Rubber feet
7. Electrical connector
8. Voltage changeover switch cover
9. Run/Standby switch
10. 15-way connector
11. Hour counter
12. Lifting eye
A730-01-880 Issue L
Introduction

1.3 Description

Refer to Figure 1 for item numbers in brackets in the following descriptions.
The XDS pump is a compact, reliable vacuum pump which is suitable for use on vapour handling processes. It may be used for some pumping applications involving corrosive substances and particulates; for information on pumping flammable gases, please refer to Section 4.5 and contact Edwards for any further assistance.
The body of the pump includes a fixed scroll and an orbiting scroll. The orbiting scroll is controlled by the electric motor through an eccentric cam on the motor drive shaft. The movement of the orbiting scroll, meshed with the fixed scroll, forms successive crescent shaped volumes in the pump. Gas that enters the pump through the inlet is compressed by the movement of the orbiting scroll and swept towards the centre of the fixed scroll. The compressed gas enters the exhaust port near the centre of the stationary scroll and is exhausted from the pump through the outlet.
The XDS is a dry vacuum pump, as all the bearings, with their hydrocarbon lubricant, are isolated from the vacuum space.
The pump has an NW40 (item 1) inlet and inlet strainer.