Read through the Safety Precautions and
each section of this Manual carefully before
using the STP pump.
Keep this Manual in a place where you can
quickly access it at any time.
Copyright 2016 Edwards Japan Limited. All rights reserved. Printed in Japan.
Manufacture:
Yuji Kato, TMP Technical Senior Manager
,
Edwards Japan
Limited
5th
June
. 2016,
Yachiyo
Date and Place
EU representative:
Ian Stones
,
Vice President, Technology
, Edwards
6th
June
. 2016, Burgess Hill
Date and Place
Declaration of Conformity
We,
Manufacture: Edwards Japan Limited
1078-1, Yoshihashi, Yachiyo-shi, Chiba, 276-8523, Japan
EU Representative: Edwards
Innovation Drive, Burgess Hill, West Sussex, RH15 9TW, UK
declare under our sole responsibility, as manufacturer and person within the EU authorised to
assemble the technical file, that the product(s)
Product Name: Turbomolecular pump
Model Number: STP-iX455/iXL455 series
Accessories Covered: Power Unit: iPS-240, Display Unit: iDT-001
Communication Interface (EtherCAT)
to which this declaration relates is in conformity with the following standard(s) or other normative
document(s)
EN1012-2:1996, A1:2009 Compressors and Vacuum Pumps.
Safety Requirements. Vacuum Pumps
EN61010-1:2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use. General Requirements
EN61326-1:2013 Electrical equipment for measurement, control and laboratory Use.
EMC requirements. General requirements
(Immunity: Industrial locations, Emission: Class A)
EN61000-6-2:2005 Electromagnetic compatibility (EMC). Generic standards.
Immunity for industrial environments
EN55011:2009, A1:2010 Industrial, scientific and medical equipment - Radio-frequency
disturbance characteristics (Group1, Class A)
EN50581:2012 Technical Documentation for the Assessment of Electrical and Electronic
Products with respect to the Restriction of Hazardous Substances
and fulfils all the relevant provisions of
2006/42/EC Machinery Directive
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility (EMC) Directive
2011/65/EU* Restriction of Certain Hazardous Substances (RoHS) Directive
* i.e. The product(s) contain less than - 0.1wt% for hexavalent chromium, lead, mercury, PBB and PBDE; 0.01wt% for
cadmium - in homogeneous materials (subject to the exemptions allowed by the Directive). The RoHS Directive does not
legally apply to industrial vacuum equipment until July 2019 (July 2017 for instruments).
Note: This declaration covers all product serial numbers from the date this Declaration was
signed onwards.
This product has been manufactured under a quality management system certified to ISO 9001:2008
VI-DOC-64-006
STP-iX455/iXL455 Series Instruction Manual
SAFETY PRECAUTIONS
The Safety Precautions in this Manual constitute guidelines to protect operators, the STP pump
and its peripheral equipment.
To avoid personal injury and prevent product and/or peripheral equipment damage, observe the
Safety Precautions as well as the general safety rules (your country’s laws, regulations, safety
standards and so on).
If the equipment is used in a manner not specified by Edwards, the protection provided by the
equipment may be impaired.
SYMBOLS
The following symbols are used in this manual:
Death or Serious Personal Injury
Failure to follow the guidelines marked with this symbol may result in death or
serious personal injury.
Minor Personal Injury, Product and/or Peripheral equipment Damage
Failure to follow the guidelines marked with this symbol may result in minor
personal injury, product and/or peripheral equipment damage.
NOTICE
Items you must follow during operation and maintenance.
◇ Symbols as Marked on the Equipment
ATTENTION : refer to this manual.
Edwards Japan Limited (abbreviated to Edwards throughout this manual) cannot perfectly
anticipate circumstances of all of hazards or problems.
The scope of anticipation is limited to the precautions included in the
and specified in this manual.
1
STP-iX455/iXL455 Series Instruction Manual
◇ The STP pump is provided with a high-speed rotor. Secure the STP pump according to the
specified method. Failure to do so may lead to serious personal injury, product and/or
peripheral equipment damage if any abnormality/error occurs in the rotor.
◇ The STP pump operates at high temperatures while the baking heater is in operation.
NEVER touch the STP pump and its peripheral equipment while the baking heater is in
operation.
Operators can burn hands.
◇ Execute the following to prevent an accident caused by the gas.
Check the properties of the gas to be used, referring to the Material Safety Data Sheet
(MSDS) you obtain from the gas supplier. (explosive・combustible・toxic・corrosive, etc)
And, keep MSDS and a safety advice of gas supplier.
Warn of the danger of the gas with the warning label when the use gas is hazardous
chemical material.
Always execute gas purge in the pump with the inert gas, and then exhaust residual
gases thoroughly from the STP pump when removing the STP pump from the vacuum
equipment.
Secure safety by wearing personal protective equipment when using the gas which
might influence damage health. In addition, take appropriate measure for depending
upon the properties of the gas to be used
◇ Exhaust residual gas thoroughly when disposing of the STP pump. If the STP pump is used
for any toxic or reactive gas, always clean the STP pump and dispose of it as industrial
waste in accordance with guidelines given by the national and/or local government. Residual
gas in the STP pump may cause an accident, for certain gases, which may involve serious
injury or death.
2
STP-iX455/iXL455 Series Instruction Manual
◇ NEVER use any gas that is not specified as usable in this Manual. The use of such gas may
corrode the STP pump and damage it.
◇ Always check the STP pump has stopped, then turn OFF the primary power supply and
isolate the electrical energy source (Lockout/Tagout) on the vacuum equipment before
proceeding to any of the following operations. Failure to do so may cause the STP pump to
rotate accidentally, which may injure operators seriously or result in electric shock.
Connect or disconnect cables;
Perform inspections such as deposit and/or the air cooling fan; or
Perform investigations into probable causes and action/measures taken in the event of
occurrence of a problem.
◇ When removing or installing the pump or at maintenance and inspection, follow the
precautions below. Failure to do so might hurt your back or cause injuries due to occurrence
of an accident such as fall.
Use a crane or the like when lifting the heavy product of 18 kg or more.
When lifting by hands for unavoidable reason, two or more people must always conduct
it.
◇ When "emergency off" (EMO) circuit is installed in the vacuum equipment, consider the
following to stop the STP pump safely when the EMO circuit operates.
When the EMO circuit operates, atmosphere might be introduced in the STP pump
depending upon the backing-pump. Unite the exhaust gas system to prevent
atmosphere from being introduced into the STP pump when the EMO circuit operates.
(example: shut the valve) When atmosphere is introduced into the STP pump, the touch
down bearing may not operate normally.
◇ Connect the cables securely. NEVER bend nor place heavy objects on the cable. Doing so
may result in electric shock or product damage.
◇ NEVER remove the splinter shield from the STP pump. Doing so may result in product
damage.
◇ DO NOT put foreign objects into the STP pump. Doing so may result in product damage.
◇ Always use the power voltage specified on the nameplates of the STP pump and the
external power supply unit. Wire the power cable securely. Incorrect wiring may result in
electric shock or product damage.
◇ The wipes used for clean the flange of the pump might become hazardous waste depending
upon the solvent (alcohol). Dispose of the contaminated wipes appropriately according to the
regulations of each national and/or local government.
◇ NEVER turn OFF the external power supply while the STP pump is rotating. Doing so may
result in product damage.
◇ Perform investigations into probable causes and remove them before restarting the STP
pump in the event of the occurrence of a problem. The use of the abnormal STP pump may
result in product damage.
◇ DO NOT move the STP pump while the STP pump is in operation. Doing so may result in
product damage.
3
STP-iX455/iXL455 Series Instruction Manual
INTRODUCTION
Thank you very much for purchasing Edwards’ turbomolecular pump.
The turbomolecular pump is designed to be installed in the vacuum equipment to exhaust
gases from it.
This manual covers all items necessary to ensure safe installation, operation and
maintenance of the following series of the STP-iX455/iXL455 turbomolecular pump:
Model Name Specification
STP- iX455
STP- iX455C
STP- iXL455
STP- iXL455C
In this manual, the above STP-iX455/iXL455 pump series is collectively referred to as the
"STP pump".
Compact type, Integrated control unit,
High-vacuum type
Compact type, Integrated control unit,
Corrosion resistant type*1
Compact type, Integrated control unit,
Low-vibration type, High-vacuum type
Compact type, Integrated control unit,
Low-vibration type, High-vacuum type,
Corrosion resistant type*1
*1
: Corrosion resistant type: STP pump with anti-corrosive treatment (responding to chlorine, fluorine or other system gases)
4
STP-iX455/iXL455 Series Instruction Manual
APPLIED STANDARDS
The STP pump conforms to the following directives and standards:
EN1012-2
EN61010-1
EN61326 (class A)
EN55011 (class A)
UL61010-1 (Electrical Equipment for Measurement, Control, and Laboratory Use)
◇ Electromagnetic compatibility
This product is a class A product according to EN61326, and a group 1, class A
product according to EN 55011. This means that this product does not generate
and/or use intentionally radio-frequency energy, in the form of electromagnetic
radiation, inductive and/or capacitive coupling, for the treatment of material or
inspection / analysis purpose and that it is suitable for use in all establishments other
than domestic and those directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes.
This product may have potential difficulties in ensuring electromagnetic compatibility in
other than industrial environments, due to conducted as well as radiated disturbances.
This product must not be used in residential areas because it may cause interference if
used in residential areas.
PRECAUTIONS
1) No part of this manual may be reproduced in any form by any means without prior
written permission from Edwards.
2) Edwards pursues a policy of continuing improvement in design and performance of this
product. The right is, therefore, reserved to vary specifications and design without
notice. Understand that the product you purchased and its contents including
specifications described in this manual may differ.
REQUEST
If you find inaccuracies or errors in this manual, advise distributor or the nearest Service
office.
5
STP-iX455/iXL455 Series Instruction Manual
LIMITED WARRANTY
This WARRANTY applies to the customer to whom Edwards has delivered this product.
1. WARRANTY PERIOD:
Edwards warrants this product against defects for a period of two (2) years from the
date of delivery or during the period specified in the agreement made by and between
the customer and Edwards.
2. ITEM WARRANTED:
1) This warranty applies only to the product delivered from Edwards to the customer.
2) If any defect is found during this period, Edwards will, at its option, repair or
recondition the product free of charge. The costs for repair or replacement of the
product after the warranty period has passed will be at your own charge.
3. DISCLAIMER:
Edwards makes no warranty with respect to any damage occurred due to any of the
following during the warranty period:
1) Handling, operation or maintenance other than that specified herein;
2) Failure to follow any of the warnings or cautions enumerated under
or;
3) Installation, operation or maintenance using parts which are not specified by Edwards;
4) Maintenance personnel other than those authorized by Edwards or Service office have
disassembled, reconditioned, or tampered the product;
5) Defect resulting from the not-specified use of the product.
6) When the product is used under special conditions without obtaining the written
consent of Edwards (Particular gases, strong magnetic field and the radiation are
added to the product.);
7) Defect resulting from deposit;
8) Water cooling system defect resulting from water quality used;
9) Defect resulting from the installation of the product (Exclude the installation by
authorized personnel.)
10) Deterioration in the external because of use (Discoloration, scratches and so forth)
11) Product damage occurred during transport or other factors not attributable to Edwards;
12) Product breakage or damage due to natural disasters, fire or other external factors;
13) Deterioration in the basic performance due to the use of the product beyond limits of
the use;
14) Any direct, incidental or consequential damage resulting from the use of the product;
15) When continuously operated without overhaul after the WARNING indication from the
STP pump;
16) Overhaul and replacement of maintenance parts;
6
STP-iX455/iXL455 Series Instruction Manual
4. SPARE PARTS: ● Touch down bearing
(When exchanging the touch down bearing, contact Service office)
● Air-cooling unit (optional accessory)
7
STP-iX455/iXL455 Series Instruction Manual
8
TABLE OF CONTENTS
SAFETY PRECAUTION
INTRODUCTION
PRECAUTIONS
REQUEST
LIMITED WARRANTY
1 Precautions for Safe Operation of the STP Pump ............................................. 1-1
Figure 15.1 External Appearance of the STP Pump (STP-iX455 series) ........................................ 15-4
Figure 15.2 External Appearance of the STP Pump (STP-iXL455 series) ...................................... 15-5
Figure 15.3 Label Affixing Positions for the STP Pump ................................................................... 15-6
12
STP-iX455/iXL455 Series Instruction Manual
CAUTION
CAUTION
1 Precautions for Safe Operation of the STP Pump
1.1 Usable Gases
Chlorine or fluorine system gases can be used in the only corrosion resistant pumps (type
C or other models). When you use gases including alkaline metals, but excluding Li, gases
including Ga, Hg, In, or Sn, or HBr, contact Edwards.
◇ To prevent an accident, confirm the characteristics of gases to be used, referring
to the Material Safety Data Sheet (MSDS) you obtain from the gas supplier.
And, keep MSDS and a safety advice of gas supplier.
◇ NEVER use corrosive gases (chlorine, fluorine, or other system gases) in the STP
pump without anti-corrosion treatment.
◇ Introduce a dry N2 gas (purge gas) to protect the inside of the STP pump when
using reactive or corrosive gas. The use of reactive or corrosive gas may result in
product damage.
◇ DO NOT use any pyrophoric gas.
◇ Cool the STP pump to prevent the STP pump from overheating when pumping
gases.
1.2 Maintenance and Inspection Precautions
Installation
Perform any maintenance or inspection of the STP pump, following Section 13,
"Troubleshooting, Maintenance, and Inspection".
◇ Always turn OFF the primary power, then turn OFF the primary power supply and
isolate the electrical energy source (Lockout/Tagout) on the vacuum equipment
before performing any maintenance or inspection.
◇ NEVER touch any portions other than those designated when performing
maintenance.
Careless touch may cause electric shock and/or a short-circuiting of the internal
circuit, resulting in product damage or a problem.
1-1
STP-iX455/iXL455 Series Instruction Manual
1.3 Labels
Installation
The following labels are affixed to the STP pump.
Read the contents of the labels before operation.
For the positions of the labels, see Figure 15.3, "Label Affixing Position for the STP
Pump".
1) STP Pump Installation Warning Label
This label describes installation of the STP pump.
Install the STP pump according to the precautions of Section 4, "Installation of the
STP Pump".
2) Rotational Direction Instruction Label
This label describes the rotational direction of the STP pump.
The STP pump rotates in this direction.
3) Hot Surface Warning Label
This label instructs operators so as not to touch the hot surface of the STP pump.
The control unit will become high temperature while the STP pump is in operation.
The use of the baking heater (optional accessory) may lead to a considerable rise in
temperatures outside the STP pump. This label warns operators so as not to burn
hands.
1-2
STP-iX455/iXL455 Series Instruction Manual
2 Operation Principle of the STP Pump
The STP-iX455/iXL455 series pump is a series of a magnetically-levitated turbomolecular
pumps, featuring the following:
Oil free
Compact size (Integrated control unit)
Low vibration
High reliability
Figure 2.1 shows the cross sectional view of the STP pump. The STP pump is configured
so that rotor blade (1) and stator blade (2) are aligned alternately in the axial direction.
The rotor blade (1) is supported by the magnetic bearing without mechanical contact.
Therefore, the STP pump requires no lubrication oil, unlike conventional turbomolecular
pumps using ball bearings.
The magnetic bearing consists of 5 pairs of active magnetic bearings. The rotor is
supported in the radial direction by 4 pairs of active magnetic bearings that consist of
radial electromagnet (3). A pair of axial electromagnets (4) supports the rotor in the axial
direction.
Because the rotor is entirely magnetically supported, it rotates with low vibration.
Moreover, STP-iXL455 series, with which the structure of low vibration and low noise (6)
and (7) are equipped, suppresses vibration and noise more than STP-iX455 series.
There is less heat generated from magnetic bearings because there is no friction.
Therefore the STP pump requires no cooling. However, the STP pump does require
water-cooling or air-cooling during baking and gas pumping.
Taking into consideration an unexpected failure of the magnetic bearings, touch-down
bearings (5) coated with solid lubrication have been installed. They do not contact the
rotor during normal operation.
The status of the rotor and magnetic bearing is continuously monitored via circuits
detecting rotor displacement, rotational speed and pump temperature. If an
abnormality/error occurs, the rotor will stop.
Installation
2-1
STP-iX455/iXL455 Series Instruction Manual
Touch down
bearing
Installation
(5)
a) STP-iX455 Series
(1) Rotor blade
(2) Stator blade
(3) Radial electromagnet
(4) Axial electromagnet
b) STP-iXL455 Series
(6) Structure for
reduce vibration level
(7) Structure for
electrical isolation
Figure 2.1 Cross Sectional View of the STP Pump
2-2
3 Unpacking
Item
Q’ty
Remarks
Instruction Manual
1
This manual
Inlet port cover
1 Outlet port cover
1
Connector for "X2 REMOTE"
1 D-
sub25 pin
Item
Q’ty
Remarks
Blank flange for purge port
1
KF*110 Clamping ring for purge port
1
KF*110 O-ring washer for purge port
1
KF*110
3.1 Unpacking the STP Pump
Check the following before unpacking the STP pump.
Check the package for bruises, breakage, wetness, and other.
If there is any abnormality/error or it is judged necessary to return the product,
contact Edwards or the distributor.
Check the contents of the package.
See Section 3.2, "Accessories".
◇ Be careful not to scratch the flange of the STP pump.
Before installing the STP pump, check whether or not there are scratches on the
surface.
◇ It is recommended to keep the packaging materials, such as the corrugated
fiberboard container and cushioning material for possible reuse.
3.2 Accessories
STP-iX455/iXL455 Series Instruction Manual
Installation
Table 3.1 Accessories
Model: NJC–207–PF
Connector for "X1 DC POWER" 1
Table 3.2 Accessories for Corrosion Resistant Pump
The accessories listed below are supplied to the corrosion resistant pump (type C or other
models) in addition to the accessories in Table 3.1.
(Nanaboshi Electric Mfg.Co,Ltd.)
Cable bushing Model: NJC–20–CB
(Nanaboshi Electric Mfg.Co,Ltd.)
*1
: ISO2861–1 (JIS–B–8365)
3-1
STP-iX455/iXL455 Series Instruction Manual
Installation
This page intentionally blank.
STP-iX455/iXL455 Series Instruction Manual
4 Installation of the STP Pump
4.1 Name and Function of Each Part
4.1.1 Name and Function of the Pump
(1) Inlet Port Flange (ICF1, VG*2, ISO*3)
● Connected to the vacuum equipment (at the high vacuum side).
(2) Outlet Port Flange (KF*425)
● Connected to the inlet port side of the backing-pump.
(3) Purge Port (KF*410)
● Port for purge gas introduction, and for vent valve attachment.
This port is only attached on the corrosion resistant pump (type C or other
models) or on pumps designed for use with a vent valve.
● Introduces a purge gas in order to protect the inside of the STP pump when
pumping reactive or corrosive gases.
● The vent valve when installed reduces the stopping time of the STP pump.
● The STP pump is delivered with a blank flange attached to this port.
(4)Control Unit
Installation
● Contains the electronics that control the pump.
Refer to Section 4.1.2, "Name and Function of the Control Unit" for details.
1
: ISO3669 or JVIS–003
*2
: JIS–B–2290
*3
: ISO1609
*4
: ISO2861–1 (JIS–B–8365)
4-1
STP-iX455/iXL455 Series Instruction Manual
(1) Inlet Port Flange
Installation
POWER
X6 VENT VALVE
X4
X1 DC POWER
1 2
3
6 7
4
ROTATION
FAILURE
X5 ST P-Link
X3 COM1
X2 RE MOTE
5
(2) Outlet Port Flange
(4) Control Unit
(3) Purge Port
Figure 4.1 Configuration of the STP Pump
4-2
STP-iX455/iXL455 Series Instruction Manual
F
1 2 3 5 6 7
P O W E R
X 1 D C P O W E R
4.1.2 Name and Function of the Control Unit
Figure 4.2 shows the front panel and Figure 4.3 shows the rear panel of the control unit.
(1)
R O T A T I O N
F A I L U R E
(2)
X 6 V E N T V A L V E
X 5 S T P - L i n k
X 4
X 3 C O M 1
(3)
X 2 R E M O T E
(10)
4
(4)
(5)
(6)
(7)
(8)
(9)
Installation
Figure 4.2 Control Unit (Front panel)
(1)"VENT VALVE" connector (X6)
● For the vent valve (optional accessory) attached in the purge port.
● Refer to Section 4.3.7, "Connecting the Vent Valve" or Section 8.1, "Vent Valve
Output" for details of the connector X6.
(2) "OPTION PORT" connector (X4: COM4) with cover
●For the network unit (optional accessory).
4-3
STP-iX455/iXL455 Series Instruction Manual
(3)"DC POWER" connector (X1)
Installation
● For power input: 48V DC.
● Includes power supply unit iPS-240 (optional accessory) communication signal.
● Refer to Section 4.5, "Connecting the DC Power Cable".
(4) "POWER" LED (green LED)
● Illuminates when 48V DC is input to the connector X1 (Power ON state).
Refer to Section 6.7, "LED".
(5) "ROTATION" LED (green/orange LED)
● The rotational speed is indicated by the flashing pattern of the LED (acceleration
state: green, deceleration state: orange).
Refer to Section 6.7, "LED".
(6) "FAILURE" LED (red/orange LED)
● A failure of the STP pump is indicated by the flashing pattern of the red LED.
The flashing pattern indicates the failure type.
Refer to Section 11, "Safety Functions" and Section 13, "Troubleshooting,
Maintenance, and Inspection".
● A warning of the STP pump is indicated by flashing of the orange LED. The
flashing pattern indicates the warning type.
Refer to Section 12, "WARNING Function".
(7) "STP-Link" connector (X5: COM2)
● For the communication cable of the STP-Link (optional accessory) or the display
unit iDT-001 (optional accessory). These optional accessories can operate the STP
pump, confirm the operation state, or change various settings.
(8) "COM1" connector (X3: Dsub9 pin)
● For RS232 and RS485 (common use) serial communication.
● For the user application.
See Section 9, "Serial Communication Protocol".
(9) "REMOTE" connector (X2: Dsub25 pin)
● For remote input/output signal in the parallel mode setting.
See Section 6.5, "Pump Operation", Section 7, "Remote Input/Output Signal
Connector".
(10) "Radiating fin"
● For dissipating heat caused by the control unit.
◇ The operation of the STP pump may lead to a considerable rise in temperatures
outside of the control unit. NEVER touch the radiating fin while the STP pump is in
operation. Operators can burn hands.
4-4
STP-iX455/iXL455 Series Instruction Manual
(11)
Installation
(11)"FAN" connecter (X7)
● Power supply for the air-cooling unit (optional accessory).
See Section 8.2, "Air-cooling Unit Output, and General-purpose Output" for
details of the connector X7.
Figure 4.3 Control Unit (Rear panel)
4-5
STP-iX455/iXL455 Series Instruction Manual
4.2 Precautions Before Installation
Installation
4.2.1 Operating Environment
◇ Check the properties of the gas to be used, referring to the Material Safety Data
Sheet (MSDS) you obtain from the gas supplier. And, keep MSDS and a safety
advice of gas supplier.
Take measures according to MSDS to prevent an accident when using toxic,
reactive or combustible gas. Dilute the gas to be used with the inert gas controlled
if necessary. And, take measures according to MSDS to prevent an accident
caused by exhaust gas.
◇ Chlorine or fluorine system gases can be used only in corrosion resistant pumps
(type C or other models). When you use gases including alkaline metals, but
excluding Li, gases including Ga, Hg, Sn, or HBr, contact Edwards.
◇ NEVER use corrosive gases (chlorine, fluorine, or other system gases) in the
models without anti-corrosion treatment.
◇ If the STP pump is used in an area with radiation, contact Edwards.
4-6
STP-iX455/iXL455 Series Instruction Manual
Ambient Temperature
0 to 40 °C
Ambient Relative Humidity
30 to 95 % (no dew condensing)
Environment
Install the STP pump securely so that foreign materials will not
easily fall into the STP pump (Ex.: Si wafers or samples are
positioned above the STP pump) (To prevent foreign materials
ng into the STP pump, design a shield plate with large
Install the STP pump in a place meeting the following requirements:
Table 4.1 Operating Environment
STP Pump Installation
Equipment Conditions
● A place free of externally-applied mechanical shock
● A place free of a heat source (Keep clear of the heat source or
attach a thermal shield plate)
● A place free of a strong magnetic field (Range: up to 15 mT
(150 G) in the axial direction, and up to 3 mT (30 G) in the
radial direction with respect to the rotational axis of the
STP pump)
● A place free of a strong electric field
● A place free of a source of electric noise
● A place free of radiation
● No discharge of high voltage (more than 500 V) (If more
than 500 V is discharged, contact Edwards)
● A place free of exposure to direct sunlight
● A place free of high humidity
● A place free of dust
● A place free of salty air
● A place free of dripping water
● A place free of explosive or flammable gas
● A place free of corrosive gas
● A place free of excessive vibration
Installation
from falli
conductance)
4-7
STP-iX455/iXL455 Series Instruction Manual
4.2.2 Installation Area
Installation
Leave enough space for the following in addition to that for the STP pump:
● Space for maintenance and inspection
● Space for connecting cables
● Space for the radiating fin of the control unit
◇ The minimum bending radius of the iPS-240 connection cable (optional
accessory) is 50 mm.*1
DO NOT excessively bend the cables and beware of any obstacles when installing
the STP pump.
In addition, leave enough space to install other cables without bending them
excessively.
4.2.3 Bench
A bench must be prepared by the customer to secure the STP pump. The shape and size of
the bench differ depending upon the vacuum equipment. Follow the precautions of the
WARNING or NOTICE.
◇ The STP pump is provided with a high-speed rotor. Any internal abnormality/error
may result in a jump in rotational torque leading to personal injury or peripheral
equipment damage.
Design and secure the bench for the STP pump so that it can withstand the
maximum torque generated due to the occurrence of an abnormality/error. Refer
to Section 4.3.3, "How to Secure the STP Pump" for abnormal torque.
◇ Secure the customer-prepared bench and the vacuum equipment on the floor or
peripheral equipment and other equipment in accordance with the customer
application. NEVER move them while the STP pump is in operation.
◇ Confirm the dimensions by the external appearance of the STP pump when
designing the bench.
The bolt may not be able to be inserted from the lower side of the inlet port
according to the shape of the inlet port flange.
When the external appearance of the STP pump is not in the manual, contact
Edwards.
*1
: Confirm the minimum bending radius of a cable when preparing it by the customer.
4-8
STP-iX455/iXL455 Series Instruction Manual
4.3 How to Install the STP Pump
◇ An appropriate enclosure or a barrier which cannot be removed without using a
tool should be provided to prevent an operator from accessing the connection
cables between the STP pump and its connectors provided.
◇ Use a lifter or the like when installing the STP pump to the vacuum equipment.
Failure to do so might hurt your back or cause injuries due to occurrence of an
accident such as fall. When lifting by hands for unavoidable reason, two or more
people must always conduct it.
Install the STP pump to the vacuum equipment as shown in Figure 4.4.
This STP pump can
be installed through
the damper (optional
accessory)
Power supply unit
(optional accessory)
power supply unit
To power supply
AC power cable
To vacuum equipment
control circuit
External
48V DC
DC power cable
Remote operation cable
X6V ENTV ALVE
X4 X3 COM1
X1D C POWER
3
POWER
ROTATION
FAILURE
X5ST P-Link
X2 REMOTE
X2R EMOTE
1 2
5
4
6 7
Vacuum
equipment
Inlet port
Installation
Inlet port flange
Outlet port flange
Vacuum
valve
Backing
-pump
Dry pump, and other
Figure 4.4 Installation of the STP Pump to the Vacuum Equipment
4-9
STP-iX455/iXL455 Series Instruction Manual
4.3.1 Cleaning the Seal
Installation
Inspect the seals of inlet and outlet port flanges for dirt or oil spots before installing the
STP pump to the vacuum equipment.
Take the following measures for cleaning the seals:
● Clean off with a pure gas.
● Wipe with proper solvent (such as alcohol).
◇ A splinter shield is attached to the inlet port flange to prevent foreign materials
from falling into the STP pump.
Always leave the splinter shield attached during operation.
◇ The wipes used for clean the flange of the pump might become hazardous waste
depending upon the solvent (alcohol). Dispose of the contaminated wipes
appropriately according to the regulations of each national and/or local
government.
◇ The splinter shield cannot perfectly prevent foreign materials from falling into the
STP pump.
DO NOT install the STP pump in such a manner that foreign materials can easily
fall into it (for example, Si wafers or samples are positioned above the STP pump).
If installing the STP pump in such a manner, always attach a shield plate with
sufficient conductance above the STP pump to prevent foreign materials from
falling into it. Foreign materials falling into the STP pump through the splinter
shield may result in product damage.
◇ Be careful not to scratch the flange of the STP pump.
Check whether or not there are scratches on the surface, before installing the STP
pump.
4-10