Edwards 94PLEDM Installation Manual

Page 1
94PLEDM Series Rotating Polaris LED Beacon Installation Sheet

Description

The 94PLEDM Series Rotating Polaris LED Beacon is UL and cUL listed for general signaling use. The beacon is available in 120 VAC or multivoltage 12 VDC, 24 VAC, or 24 VDC models. There are six lens colors to choose from, and a choice of black or gray bases. The beacon utilizes high-power LED lights and is suitable for indoor or outdoor use. The beacon is provided with an enclosure rated for NEMA Type 4X and IP66.
The beacon is well suited for high ambient noise level areas, especially where ear protection must be worn. The beacon is also ideal for high vibration applications and areas where long lamp life is advantageous. The beacon features a 360-degree beam of light with 16 user­selectable flash or rotation patterns including Steady. The patterns are selected by pressing the Edwards logo push button. The factory setting is Light Burst.
The beacon is designed to be mounted on 3/4 in. NPT conduit (indoor or outdoor). To maintain the NEMA Type 4X and IP66 ratings for outdoor installation, the beacon must be mounted with the dome facing directly up. When installing the beacon indoors in dry environments, it can be mounted in any position.

Installation

Install the beacon in accordance with the applicable requirements in the latest edition of the National Electrical Code, Canadian Electrical Code, and local codes.
WARNINGS
Electrocution hazard. To prevent electrical shock, ensure that
power is disconnected before installing the beacon
Electrocution hazard. To prevent leakage and potential electrical
shock, use care when disassembling the beacon to prevent tearing of the permanently affixed gaskets provided for the environmental integrity and ratings.
Electrocution hazard. To prevent leakage and potential electrical
shock when mounting outdoors, install the beacon with the lens or dome facing directly up.
To install the beacon:
1. Release the latch on the clamp ring and remove the ring holding the protective dome to the signal base. Lift the dome straight up off of the beacon base (Figure 1).
2. Loosen the three screws in the keyhole slots in the base of the lens, turn the lens clockwise, and lift it off of the LED light source support plate.
3. Remove the three screws holding the LED light source support plate to the beacon base.
4. Gently grasp the LED tower and carefully lift the support plate off of the beacon base.
Note: The beacon mounts on a 3/4 in. NPT conduit pipe. The
female threaded entry is located on the bottom of the base.
5. Route the field wiring from the appropriate power source through the conduit, and then through the conduit entrance hole in the beacon base.
6. Install the base on the conduit. Wrench-tighten for a leak free seal.
7. Wire in accordance with “Wiring” below.
8. Place the connected wires inside the base and reassemble the beacon (Figure 1).
9. Apply power and verify that the beacon operates properly.

Wiring

Wire this unit in accordance with all applicable local codes and standards and the local authority having jurisdiction.
To wire the beacon for 120 VAC:
1. Using wire nuts (not supplied), connect the field wiring to the beacon wiring.
2. Connect the beacon’s black lead to hot, and the white lead to neutral. Connect the beacon’s green lead to the grounding point located in the signal base.
To wire the beacon for 12 VDC:
1. Using wire nuts (not supplied), connect the field wiring to the beacon wiring.
2. Connect the beacon’s red lead to positive (+) and the black lead to negative (−).
To wire the beacon for 24 VAC/VDC:
1. Connect the field wiring to the beacon wiring using wire nuts (not supplied).
2. Connections depend on the voltage supply. Choose the connections that match your power supply:
24 VAC: Connect the black lead to hot and the red lead to neutral. 24 VDC: Connect the red lead to positive (+), and the black lead to
negative (). Connect the green lead to the grounding point located in the beacon base.

Selecting the flash or rotation pattern

The beacon can be configured with one of 16 user-selectable flash or rotation patterns using a push button (membrane switch). The push button is located in the center of the Edwards shield logo on the base of the beacon (Figure 1).
Note: The beacon is designed to be conduit mounted.
© 2017 United Technologies Corporation 1 / 3 P/N 3101962-EN • REV 003 • ISS 26OCT17
Page 2
Table 1: Flash and rotation patterns
Pattern
Description
1.
2. S65
3. Light Burst
4. Singular Burst
5. Binary Burst
6. Quad Burst
7. iBurst
8. Rotating
9. Rotating
10. Rotating
11. Rotating
12. Slow Rotating with Burst
13.
14. Quad Flash with Pop
15. Variable Rotating
83 to 420 RPM repeated every 6.6s
16. Variable
FPM RPM – Rotations Per Minute
(1) Dome (2) (3) (4) (5) Screw (3X)
(6) LED light source support plate ( ( (9)

Cleaning

Steady On steady
65 Single FPM
1,100 FPM (seven pulses),
310 Single FPM
200 Double FPM
100 Quad FPM
4 pulses at 750 FPM, Off,
80 RPM 80 RPM 95 RPM 95 RPM
130 RPM 130 RPM 200 RPM 200 RPM
Flash Rotating with Burst 3 rotations at 174 RPM,
4 pulses at 650 FPM, 160ms Off,
Flashing 137 - 535 Single FPM repeated
– Flashes Per Minute
To select a flash or rotation pattern:
1. Press and hold the push button for one second to switch the beacon to the next pattern (Table 1).
2. Press and hold the push button for three seconds to set the beacon to the first pattern (Steady).
440 ms off, Repeat
4 pulses at 750 FPM, Off, 6 pulses at 870 FPM, Off, Repeat
2 rotations at 84 RPM,
2 pulses at 940 FPM, Repeat
4 pulses at 900 FPM, Repeat
1 pulse at 410 FPM, 410 ms Off, Repeat
every 4.1s
Caution: To prevent damage to the lens or dome, do not use abrasive
materials or cleaners.
Periodically clean the lens surface with a soft cloth or sponge and water or a mild detergent solution to maintain optimum light visibility. Make sure the lens is completely dry before assembling the beacon.
Figure 1: Installation
Lens Screw (3X) LED tower
7) Beacon base
8) Clamp ring Push button

Maintenance

Lens and dome replacement WARNING: Electrocution hazard. To prevent electrical shock,
disconnect the beacon from the supply circuit and allow five minutes for stored energy to dissipate before disassembling.
Caution: Do not overtighten the screws or damage to the dome may
occur.
To replace the lens or dome:
1. Release the latch on the clamp ring and remove the ring holding the protective dome to the signal base. Lift the dome straight up off of the signal base.
2. Loosen the three screws in the keyhole slots in the base of the lens. Turn the lens clockwise and lift it straight up off of the support plate.
3. Replace the lens by turning it counter-clockwise in the keyhole slots, and then tightening the three screws.
4. Replace the dome and reinstall the clamp ring.
2 / 3 P/N 3101962-EN • REV 003 • ISS 26OCT17
Page 3

Specifications

Model number
Electrical specs
Dimensions
Color
G
94PLEDMA24AD
94PLEDMB24AD
94PLEDMG24AD
94PLEDMM24AD
94PLEDMR24AD
94PLEDMW24AD 94PLEDMA120A
94PLEDMB120A
94PLEDMG120A
94PLEDMM120A
94PLEDMR120A
94PLEDMW120A
Specification
Operating voltage
Off state leakage current
Continuous Surge (inrush/duration)
* The letter in this position denotes color.
Component
Clear outer
Lens*
* B
For example,
a part number for a red lens would be 93-LR.
North American standards
Table 2: Specifications
ray base Black base
94PLEDMA24ADB 12 VDC, 0.700 A
94PLEDMB24ADB 12 VDC, 0.700 A
94PLEDMG24ADB 12 VDC, 0.700 A
94PLEDMM24ADB 12 VDC, 0.700 A
94PLEDMR24ADB 12 VDC, 0.700 A
94PLEDMW24ADB 12 VDC, 0.700 A
94PLEDMA120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) Amber 94PLEDMB120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) Blue
94PLEDMG120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) Green 94PLEDMM120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) Magenta
94PLEDMR120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) Red
94PLEDMW120AB 120 VAC, 0.250 A 8.25 × 7.75 in. (210 × 200 mm) White
24 VAC/VDC 0.550 A
8.25 × 7.75 in. (210 × 200 mm) Amber
8.25 × 7.75 in. (210 × 200 mm) Blue
24 VAC/VDC 0.550 A
8.25 × 7.75 in. (210 × 200 mm) Green
24 VAC/VDC 0.550 A
8.25 × 7.75 in. (210 × 200 mm) Magenta
24 VAC/VDC 0.550 A
8.25 × 7.75 in. (210 × 200 mm) Red
24 VAC/VDC 0.550 A
8.25 × 7.75 in. (210 × 200 mm) White
24 VAC/VDC 0.550 A
Figure 2: Dimensions
Table 3: Electrical specifications
94PLEDM(*)24AD 94PLEDM(*)120A
12 VDC
24 VAC/VDC 5 mA 5 mA
On current 700 mA (12 VDC)
550 mA (24 VAC/VDC)
8.5 A / 2 ms 4.5 A / 1 ms
120 VAC
250 mA
Table 4: Replacement parts
Catalog number
dome 94DV2-DC
93-L(*)
The letter in this position signifies the color of the lens. A = amber,
= blue, C = clear, G = green, M = magenta, or R = red.
Note: 94PLEDMW uses a clear lens.

Regulatory information

Contact information

For contact information, see www.edwardsfiresafety.com.
UL 1638A, cUL C22.2 No. 205