Edwards 10 Instruction Manual

C410-01-882
Issue B Original
Instruction Manual
Model 10 Water Jet Pump
This page has been intentionally left blank.
© Edwards Limited 2009. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
C410-01-882 Issue B
Contents
Section Page
1 Technical Data ....................................................................................1
2 Construction .................................................. ..................................... 2
3 Installation notes .................................................................................3
For return of equipment, complete the HS Forms at the end of this manual.
Illustrations
Figure Page
1 Model 10 Water Jet Pump .............................................................................................. 3
Associated publications
Publication title Publication number
Vacuum pump and vacuum system safety P400-40-100
edwards jp 08/09
C410-01-882 Issue B
Page ii © Edwards Limited 2009. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Contents
© Edwards Limited 2009. All rights reserved. Page 1 Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical Data
C410-01-882 Issue B
1Technical Data
Note: *Performance is limited only by the temperature and pressure of the water supply. At a water pressure of
1.4 bar (20 lbf in-2) and a temperature of 15 ºC, the pumping speed is approximately 3.9 l min-1, and the ultimate vacuum 17 mbar. Water consumption is approximately 625 l h
-1
.
The Model 10 pump operates from standard water supplies to produce rough vacuum for application in the distillation, filtration aeration fields and general duties not requiring higher performance mechanical vacuum pumps.
Model 10 Operating water pressure (optimum) 1.4 bar (20 lbf in -2) Operating water temperature 15 ºC Operating water pressure (recommended) 1 to 2 bar (15 to 30 lbf in
-2
)
* Pumping speed (air) 3.9 l min
-1
Ultimate vacuum 16 to 18 mbar Water consumption 625 l h
-1
Connections
Water in 12 mm bore tubing Drain 3/8 in (9.5 mm) bore tubing V acuum 7 mm bore tubing Weight 34 g
Product Description Order number
Model 10 water jet pump C410-01-000
Spares Order number
Viton ball/pin assembly for non-return valve C039-01-010
C410-01-882 Issue B
Page 2 © Edwards Limited 2 0 09. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Construction
2Construction
The pump is constructed from a plastic material (PPS) which has high corrosion resistance properties. The material is non-flammable and is resistant to a wide range of solvents, mineral and organi c acids and alk alis. It must NOT be used with the following:
Bromine (wet)Butyl AmineChlorosulfonic AcidChlorine (dry)Chromic Acid ConcHydrogen peroxide 30%MorpholineNitric Acid 35% to ConcSulphuric Acid 98%Trichlorethylene
Riffled nozzles are provided on the pump for the water and vacuum connections and an internal non-return valve prevents flooding of the vacuum system in the event of fluctuating water pressure.
C410-01-882 Issue B
Page 3 © Edwards Limited 2 0 09. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
This page has been intentionally left blank.
3 Installation notes
1. Connection to the water supply should be made using 12 mm bore tubing and to the vacuum system usin g 7 mm bore vacuum tubing. If it is desired to fit a water drain, thus should be of 9.5 mm bore tubing.
Note: After considerable service, the tubing may stick to the nozzles and it should be removed by cutting.
2. Should the jet nozzle assembly or the vacuum connection be removed:
Ensure ball valve is located correctly in the vacuum arm, on re-assembly, so that the pin projects towards
the centre line of the jet nozzle assembly.
The vacuum nozzle should be carefully tightened to a torq ue se ttin g no t excee di ng 18 lbf in (ma ximu m) and
the jet nozzle to a torque setting not exceeding 24 lbf in (maximum).
CAUTION
The ball valve is manufactured from an elastomer which is liable to swell in the presence of certain chemical (particularly ketones and esters). Should the pump cease to operate when such chemicals are present, then the valve is suspect and should be inspected. Access to the valve is obtained by unscrewing the vacuum nozzle. Renew the valve ball if swollen or deteriorated.
Figure 1 - Model 10 Water Jet Pump
1. Water inlet
2. Jet nozzle assembly (C410-01-001)
3. Ball/Pin assembly (C039-01-010)
4. Vacuum connection (C410-01-004)
5. Vacuum
6. Body (C410-01-005)
7. Water drain
C410-01-882 Issue B
Page 4 © Edwards Limited 2 0 09. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
This page has been intentionally left blank.
Loading...