EDS CD 310, CD 330, CD 330R Instruction Manual

SERVICE
8 8
CD310_Eng_260109R1
INSTRUCTION MANUAL
CARBON MONOXIDE DETECTOR
CD 310 / CD 330 / CD 330R
EDS Elektronik Destek Sanayi ve Ticaret Ltd. Þti.
Meclis Mah. Teraziciler Cad. Kýlýç Sok. No:4 34785 Sarýgazi/ Ýstanbul
www.eds.com.tr eds@eds.com.tr
+90 216 528 45 00 +90 216 314 17 80
Ph. Fax
: :
CD310/330/330R
2/8
CO gas is lighter than air, it will moves higher in the room, install the dector due to the Figure 2. LPG exists in lower side of the room, install the detector due to Figure 3. Install detector away from fans and air absorbing equipments. CO detector, designed for detecting gas leakage and warning by sound and red alarm led. Connecting alarm or security panels and fans by relay outputs. Detecting capability of Ideal for home and office use due to the compact design.
Introduction
Figure:12
7/8
Power
Model
12V DC
220V AC
-
Power Comsumption
2.5W
External Horn Output
105g
Weight Relay Output
1A 12V (COM, NC, NO)
Protection Area
50squaremeters
Sensor Type
Semi Conductor
Sensor Life
Avaible Conditions 5 Years
Heating
15 min.
DetectionTime
<2,5mins Operating Temperature Humidity
-10C +50C
0-95 Not Saturated Siren Output
Piezoelectrical Buzzer
Led Display: Operating
Green Led
Sound Level
85dB
Red Led
Housing
ABS Color
White Dimensions
143mm x 83mm x 30mm Fuse
Auto
12V DC
Led Display: Alarm
1
2
3
4
9
7
8
7
9
3
2
1
4
5
7
9
8
5
Technical Specifications
Figure:1
Installation
Installation CD310 should be done with 2pcs of 6mm wall plugs and 2pcs of 3.5x30mm screw. Remove upper part of plastic cover by the help of hutch(Figure 1, point 6). Install CD310 by using installation holes and gas absorbing holes which refers to the base of the room, smooth plane of wall. Install wall plugs and bottom part of plastic cover. Make suitable cable connection. Place uppert part of plastic cover; gas absorbing holes refers to the base. After power up, push test switch and test gas detector. Pushing test switch red led on and buzzer warns by sound.
6
6
Figure:13
At A Glance To The Detector
6
9
9
CARBON MONOXIDE DETECTOR
CD310/330/330R
CARBON MONOXIDE DETECTOR
Yellow Led
Led Display: Fault
CD310 CD330R CD330
10
Red Led- Alarm/Yellow Faulth
Test Switch
Green Led - Operating
Gas Absorbing Holes
Sound Emitting Hole
Hutch
Cable Holes
Label
Installation Holes
Power Supply Socket