Edison ED-16B User Manual

Page 1
Edison Dehumidifier
Model: ED-16B
USER’S MANUAL
Page 2
2
PRODUCT INTRODUCTION
1. Displ
ay panel
2. Air outlet
3. Handel
4. Front housing
5. Humidity control switch
6. Air Inlet / Back housing
7. Drain hole
8. Water tank
1
SAFETY
INFORMATION
1.
Please read the manual carefully before the first time using this product, and storage the unit in safe place to avoid electricity leakage, flaming or person injure.
2. Do not put this product in the water or any other liquids.
3. Stop using this appliance in below situations, or the product might be damaged: power cord and wire is broken, the unit is dropped or break down.
4. Please ask professional service agent to repair the product. Improper repair might cause damage to users.
5. Disconnect the appliance from power supply before moving or cleaning the product, and also when the product is not in used.
6. Please operate the product with specified electricity voltage.
7. Please use this product only for household appliance and follow the designed purpose.
8. Do not put any stuff on the product.
9. In order to avoid water leakage, please clean the water tank before moving the product.
10. Do not incline the product, or leaking water may damage the
product.
11. This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been supervised or given instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
12. Please keep the product from the wall or other barriers in a
minimum distance of 50 cm.
13. Please install the appliance following the country wiring laws.
Display panel
Page 3
4
6. If the dehumidifier can’t start (the indicating light does not illuminate) or the dehumidifier shut down unreasonably, please make sure whether the plug is connected firmly to power
supply. If the plug and power supply are in normal condition, please wait for 10 minutes before restart the unit (because it takes 10 minutes to reposition). If the unit still does not start after 10 minutes, please ask your local distributor service station to repair.
7. When the dehumidifier is operating, it’s a normal situation that the working compressor may cause some heat and bring the ambient temperature up.
8. When the product is defrosting, the related indicating light will illuminate. And during the defrosting, the compressor will stop but the motor will keep working.
DRAINING
INSTRUCTION
Draining water can storage in the water tank, or be continuous
drained by PVC tube. (The PVC tube is not included in the product.)
USAGE OF WATER TANK
When dehumidifying, the condensing water may be drained to water tank. And the unit will stop working with indicating light illuminating when the water tank is full of water, please pour out the water that time.
1. Take out the water tank as Fig 01,
and pour out the water.
2. Put the water tank back.
Fig 01
3
OPERA
TING INSTRUCTION
ST
ARTING THE UNIT
1.
First, please rotate the humidity switch in a leftward direction to the end (which is the “OFF” position).
2. Plug in the dehumidifier.
3. Rotate the humidity switch in a leftward direction to turn on the unit. The humidity will decrease every time you rotate the switch to left side, and it will enter continuous humidifying mode when you rotate it to the end.
TURNING O
FF THE UNIT
1.
Please rotate the humidity switch in a rightward direction to the end, and then the unit will be turned off.
2. If the dehumidifier is not in use for a long time, please disconnect the power cord plug from the outlet.
WA
RNING
1.
When operating the dehumidifier, please do not set the humidity higher than ambient humidity.
2. When indicating light illuminates, please pour the water out of the tank and put it back. Then the product will resume working.
3. When the product shut down, please wait at least 3 minutes before restarting the unit to prevent damaging the compressor.
4. The value on the calibration shows the relative humidity.
5. The applicable operating temperature range for this unit is 5-32.
automatically.
3. Then the unit will follow the setting humidity to work
Page 4
6
3. Please disconnect the power cord to the power supply when you turn off the unit or intend to stop using for long time.
4. In order to improve the performance of dehumidifier, please keep the unit in open place away from barriers which may block the air.
5. Please wash the filter with cool water (cooler than 40 ) ℃ but not gasoline or alcohol every two weeks, and put filter back after it air-dried naturally.
5
CONTINUOUS DRAI
NAGE
1.
Before continuous draining water, please take out the water tank and plug a draining tube to draining hole. (See Fig
02.) Then put the water tank back.
2. Draining tube should place lower than the draining hole to let water flow out.
FILTER REMOVAL
1.
Take out the water tank before remove the filter.
2. Pulling out the filter with handles of
filter.
3. Wash the filter with cool water (cooler
than 40) every two weeks, and put filter back after it air-dried naturally.
MAINTENANCE INSTRUCTION
1.
The unit is not allowed to be placed on surface which is soft or not flat to avoid the unit cause noise, vibration, and water or electricity leakage when operating.
2. Never insert any slim rod or hard stuff into the unit to avoid the
damage of the unit.
Fig 02
WARRANTY POLICY
The warranty period is 12 months from the date of purchasing.The warranty is limited to free replacement and shippingof any faulty part, or manufacturing errors. All claims mustbe supported by evidence that the failure has occurredwithin the warranty period, and that the unit has been operatedwithin the designed parameters specified.
All warranty claims must specify the model/serial number.These details are printed on the unit identification plate.
Page 5
Copy ri
ght Naav Solutions Inc. 2012 All Rights Reserved.
Reference in this publication to Edison products or services do not im
ply that Edison intends to make them available outside the territories served by its sales companies or distributors.
O5L2
144
Dry for good !
Naav Soluti
ons Inc (NSI)., reserves the right to change specifications or other product information without notice. This publication could include technical inaccuracies or typographical errors.
NSI PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdications do not allow disclaimer of express or implied warranties; therefore this disclaimer may n
l .
Edison
N842/
2006
R134a
Kyoto Co
vered
7
SPECIFICA
TIONS
M
odel
Specification
ED-16B
Po
wer Supply 220-240V~50Hz
Po
wer Input 410W
Rated C
urrent 2.1A
Net W
eight 13.3Kg
Moisture Removal (30 RH
80%)
16 liters/day
Dimens
ion(W x D x H) mm
362Wx220Dx508H
Appl
icable temperature
5-32
W
ater T ank Capacity 2.5L
(CE) N 842/2
006: R134a is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol. Its total global warming potential (GWP) is 1300
This marking indicates that this product should not
be disposed with other household wastes throughout the EU. To prevent possible hazards to the environment or human health from uncontrolled waste disposal, please recycle it to prove the sustainable reuse of material resources. Please ask return and collection systems or contact the retailer where the product was purchased to return your used device, they can recycle products
8
Loading...