Edirol S-4000S ARCHITECTS AND ENGINEERS SPECIFICATION

Architects & Engineers Specication
S-4000S Digital Snake System
The digital audio transmission system (Digital Snake) shall be a modular system
that can be congured in groups of 8 channels up to a maximum of 40 channels per transmission cable. The system shall consist of one Input or Stage Box Module, with XLR or AES/EBU inputs, as well as the option for multiple line-level “returns” or Outputs. It will also consist of at least one Output or Front-of-House (FOH) Module that will have line level outputs as well as the option for some line level inputs or returns.
The modularity shall allow for different congurations of the Input Module or Stage Box including 40 inputs and 0 outputs, 32 inputs and 8 outputs, or 24 inputs and 16 outputs. The transmission cable between the Input or Stage Box Module and the Output or FOH Module(s) shall be a Cat5e or Cat6 cable.
The inputs shall be of very high quality and accept both line and microphone level inputs with individually selectable phantom power. The input gains or trims for the inputs as well as their phantom power settings, shall be remotely controllable from the Stage or FOH Module using either a hardware remote control unit or a computer.
steps. The system shall also offer at least 10 preset memories of different congurations of the input gain and phantom power settings.
The audio protocol for a 40-channel system shall have a 96 kHz sampling rate, provide 24-bit audio, and have a protocol latency of 375 microseconds from the stage unit to the FOH unit. The system shall have redundant Ethernet ports allowing the connection of two Cat5e or Cat6 cables from the Input unit to the FOH unit. The system shall be designed to switch automatically from one cable to the other in the case of damage to one of the cables. The system shall allow the user to copy or “split” the input sources to several Output Modules using a fast gigabit Ethernet switching hub.
S-4000S-3208 Stage Unit Dimensions
440
434.6
336265.4
482 465
57.176.257.1
S-4000R Remote Control Dimensions
60.9
215
87.8
54.3
54.6
266.4
89.2
S-4000H FOH Unit Dimensions
440
434.6
365.8
482 465
57
132.5
386.7
133.8
The system shall be the Roland S-4000S Digital Snake System.
801 West Orchard Drive, Suite 3 Bellingham, WA 98225
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
WWW.ROLANDSYSTEMSGROUP.COM
Architects & Engineers Speci cation
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
Input: 32 (XLR type, balanced, phantom power, 4 ch input module x 8)
* 0 dBu = 0.775 Vrms
* 0 dBu = 0.775 Vrms
S-4000S Digital Snake System
S-4000 Digital Snake System Main Specifications
S-4000S-3208 40CH I/O MODULAR RACK
Number of Channels
AD Conversion
DA Conversion
Frequency Response Total Harmonic
Distortion + Noise Dynamic Range Cross Talk
Nominal Input Level
PAD Input Impedance Nominal Output Level Output Impedance
Recommended Load Impedance
Residual Noise Level (IHF-A, typ.)
Equivalent Input Noise Level (E.I.N.)
Network Latency
32 in 8 out Sample Rate: 96.0 kHz Signal Processing: 24 bit
Sample Rate: 96.0 kHz Signal Processing: 24 bit
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less (Pad: On, Input Gain: +4 dBu, 22 to 20000 Hz)
110 dB
-80 dB
-65 to -10 dBu (PAD: Off) -45 to +10 dBu (PAD: On) (1 dB step, Max. +28 dBu)
20 dB On/Off 20 k ohms +4 dBu, Max. +22 dBu 150 ohms
10 k ohms or greater
-90 dBu
-128 dB
375 microseconds when using REAC cable only (AD - REAC - DA Latency: about 1.2 ms)
Connectors
Indicator
AC Power Supply DC Power Supply Power Consumption Current Draw
(for an optional external power supply unit; Model S-240P)
Phantom Power
Dimensions
Weight Operation Temperature
Accessories
Output: 8 (XLR type, balanced, 4 ch output module x 2) REAC: MAIN, BACKUP (RJ-45 EtherCon type) Remote Connector: 1 (RS-232C, DB-9 type) MIDI Connectors: IN, OUT (5-pin DIN type)
EXT Indicator (External Power Supply Unit) INT Indicator REAC Indicator CTRL Indicator ALARM Indicator MUTE ALL OUTPUTS Indicator
+24 V (from optional external power supply unit : S-240P): 130 W
6 A
+48 V / 14 mA (each input on SI-AD4, remote controlled)
482.0 (W) x 336.0 (D) x 266.4 (H) mm 19 (W) x 13-1/4 (D) x 10-1/2 (H) inches
17.0 kg, 37 lbs 8 oz 0 to +40 degrees Celsius +32 to +104 degrees Fahrenheit
Power Cord, REAC cable (10 m, Cat5e crossover cable) Adhesive-backed number label sheets, REAC Connector Covers Ferrite Cores, Owner's Manual
S-4000H 8X32 FOH UNIT
Number of Channels
AD Conversion
DA Conversion
Frequency Response
Total Harmonic Distortion + Noise Dynamic Range Cross Talk Nominal Input Level Input Impedance Nominal Output Level Output Impedance
Recommended Load Impedance
Residual Noise Level (IHF-A, typ.)
Network Latency
Connectors
8 in 32 out Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Sample Rate: 96.0 kHz Signal Processing: 24 bit
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less (Input Gain: +4 dBu, 22 to 20000 Hz)
110 dB
-80 dB +4 dBu, Max. +22 dBu 30 k ohms +4 dBu, Max. +22 dBu 600 ohms
10 k ohms or greater
-90 dBu
375 microseconds when using REAC cable only (AD - REAC - DA Latency: about 1.2 ms)
Input: 1 (DB-25 type, balanced, 8 channels) Output: 4 (DB-25 type, balanced, 32 channels each) REAC: MAIN, BACKUP (RJ-45 EtherCon type) Remote Connector: 1 (RS-232C, DB-9 type) MIDI Connectors: IN, OUT (5-pin DIN type)
S-4000R REMOTE CONTROL UNIT
Connector Indicators Power Supply Dimensions Weight Operation Temperature Accessories
Remote Connector: 1 (RS-232C, DB-9 type) CLIP Indicators, SIG Indicators, POWER Indicator, REAC Indicator, CTRL Indicator, Level Meter Supplied from connected device. (S-4000S, S-4000H; through the remote cable)
215.0 (W) x 87.0 (D) x 54.6 (H) mm, 8-1/2 (W) x 3-7/16 (D) x 2-3/16 (H) inches
0.8 kg, 1 lb 13 oz 0 to +40 degrees celsius, +32 to +104 degrees Fahrenheit Remote Cable (3 m), Rack Mount Brackets, Installation Manual
EXT Indicator (External Power Supply Unit) INT Indicator
Indicators
AC Power Supply DC Power Supply Power Consumption Current Draw
(for an optional external power supply unit; Model S-240P)
Dimensions
Weight
Operation Temperature
Accessories
REAC Indicator CTRL Indicator ALARM Indicator MUTE ALL OUTPUTS Indicator
+24 V (from optional external power supply unit : S-240P): 70 W
6 A
482.0 (W) x 386.7 (D) x 133.0 (H) mm 19 (W) x 15-1/4 (D) x 5-1/4 (H) inches
9.4 kg, 20 lbs 12 oz 0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
Power Cord, REAC Connector Covers, Ferrite Cores, Connector Guard, Screws for Connector Guard Installation Manual
801 West Orchard Drive, Suite 3 Bellingham, WA 98225
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
WWW.ROLANDSYSTEMSGROUP.COM