Architects & Engineers Specication
S-4000S Digital Snake System
The digital audio transmission system
(Digital Snake) shall be a modular system
that can be congured in groups of 8
channels up to a maximum of 40 channels
per transmission cable. The system shall
consist of one Input or Stage Box Module,
with XLR or AES/EBU inputs, as well as
the option for multiple line-level “returns” or
Outputs. It will also consist of at least one
Output or Front-of-House (FOH) Module
that will have line level outputs as well as
the option for some line level inputs or
returns.
The modularity shall allow for different
congurations of the Input Module or Stage
Box including 40 inputs and 0 outputs, 32
inputs and 8 outputs, or 24 inputs and 16
outputs. The transmission cable between
the Input or Stage Box Module and the
Output or FOH Module(s) shall be a Cat5e
or Cat6 cable.
The inputs shall be of very high quality
and accept both line and microphone level
inputs with individually selectable phantom
power. The input gains or trims for the
inputs as well as their phantom power
settings, shall be remotely controllable from
the Stage or FOH Module using either a
hardware remote control unit or a computer.
The gain level shall be controllable in 1 dB
steps. The system shall also offer at least 10
preset memories of different congurations
of the input gain and phantom power
settings.
The audio protocol for a 40-channel system
shall have a 96 kHz sampling rate, provide
24-bit audio, and have a protocol latency of
375 microseconds from the stage unit to the
FOH unit. The system shall have redundant
Ethernet ports allowing the connection of
two Cat5e or Cat6 cables from the Input
unit to the FOH unit. The system shall be
designed to switch automatically from one
cable to the other in the case of damage to
one of the cables. The system shall allow
the user to copy or “split” the input sources
to several Output Modules using a fast
gigabit Ethernet switching hub.
S-4000S-3208 Stage Unit Dimensions
440
434.6
336265.4
482
465
57.176.257.1
S-4000R Remote Control Dimensions
60.9
215
87.8
54.3
54.6
266.4
89.2
S-4000H FOH Unit Dimensions
440
434.6
365.8
482
465
57
132.5
386.7
133.8
The system shall be the Roland S-4000S
Digital Snake System.
801 West Orchard Drive, Suite 3
Bellingham, WA 98225
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
WWW.ROLANDSYSTEMSGROUP.COM
Architects & Engineers Speci cation
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
AC 115 V, AC 117 V, AC 220 V, AC 230 V, AC 240 V (50/60 Hz)
Input: 32 (XLR type, balanced, phantom power, 4 ch input module x 8)
* 0 dBu = 0.775 Vrms
* 0 dBu = 0.775 Vrms
S-4000S Digital Snake System
S-4000 Digital Snake System Main Specifications
S-4000S-3208 40CH I/O MODULAR RACK
Number of Channels
AD Conversion
DA Conversion
Frequency Response
Total Harmonic
Distortion + Noise
Dynamic Range
Cross Talk
Nominal Input Level
PAD
Input Impedance
Nominal Output Level
Output Impedance
Recommended Load
Impedance
Residual Noise Level
(IHF-A, typ.)
Equivalent Input
Noise Level (E.I.N.)
Network Latency
32 in 8 out
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less
(Pad: On, Input Gain: +4 dBu, 22 to 20000 Hz)
110 dB
-80 dB
-65 to -10 dBu (PAD: Off) -45 to +10 dBu (PAD: On)
(1 dB step, Max. +28 dBu)
20 dB On/Off
20 k ohms
+4 dBu, Max. +22 dBu
150 ohms
10 k ohms or greater
-90 dBu
-128 dB
375 microseconds when using REAC cable only
(AD - REAC - DA Latency: about 1.2 ms)
Connectors
Indicator
AC Power Supply
DC Power Supply
Power Consumption
Current Draw
(for an optional external
power supply unit;
Model S-240P)
Phantom Power
Dimensions
Weight
Operation Temperature
Accessories
Output: 8 (XLR type, balanced, 4 ch output module x 2)
REAC: MAIN, BACKUP (RJ-45 EtherCon type)
Remote Connector: 1 (RS-232C, DB-9 type)
MIDI Connectors: IN, OUT (5-pin DIN type)
EXT Indicator (External Power Supply Unit)
INT Indicator
REAC Indicator
CTRL Indicator
ALARM Indicator
MUTE ALL OUTPUTS Indicator
+24 V (from optional external power supply unit : S-240P):
130 W
6 A
+48 V / 14 mA (each input on SI-AD4, remote controlled)
482.0 (W) x 336.0 (D) x 266.4 (H) mm
19 (W) x 13-1/4 (D) x 10-1/2 (H) inches
17.0 kg, 37 lbs 8 oz
0 to +40 degrees Celsius +32 to +104 degrees Fahrenheit
Power Cord, REAC cable (10 m, Cat5e crossover cable)
Adhesive-backed number label sheets, REAC Connector Covers
Ferrite Cores, Owner's Manual
S-4000H 8X32 FOH UNIT
Number of Channels
AD Conversion
DA Conversion
Frequency Response
Total Harmonic
Distortion + Noise
Dynamic Range
Cross Talk
Nominal Input Level
Input Impedance
Nominal Output Level
Output Impedance
Recommended Load
Impedance
Residual Noise Level
(IHF-A, typ.)
Network Latency
Connectors
8 in 32 out
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
Sample Rate: 96.0 kHz
Signal Processing: 24 bit
-2 dB / +0 dB (@ +4 dBu, 20 Hz to 20 kHz)
0.05 % or less (Input Gain: +4 dBu, 22 to 20000 Hz)
110 dB
-80 dB
+4 dBu, Max. +22 dBu
30 k ohms
+4 dBu, Max. +22 dBu
600 ohms
10 k ohms or greater
-90 dBu
375 microseconds when using REAC cable only
(AD - REAC - DA Latency: about 1.2 ms)
Input: 1 (DB-25 type, balanced, 8 channels)
Output: 4 (DB-25 type, balanced, 32 channels each)
REAC: MAIN, BACKUP (RJ-45 EtherCon type)
Remote Connector: 1 (RS-232C, DB-9 type)
MIDI Connectors: IN, OUT (5-pin DIN type)
S-4000R REMOTE CONTROL UNIT
Connector
Indicators
Power Supply
Dimensions
Weight
Operation Temperature
Accessories
Remote Connector: 1 (RS-232C, DB-9 type)
CLIP Indicators, SIG Indicators, POWER Indicator, REAC Indicator, CTRL Indicator, Level Meter
Supplied from connected device. (S-4000S, S-4000H; through the remote cable)
215.0 (W) x 87.0 (D) x 54.6 (H) mm, 8-1/2 (W) x 3-7/16 (D) x 2-3/16 (H) inches
0.8 kg, 1 lb 13 oz
0 to +40 degrees celsius, +32 to +104 degrees Fahrenheit
Remote Cable (3 m), Rack Mount Brackets, Installation Manual
EXT Indicator (External Power Supply Unit)
INT Indicator
Indicators
AC Power Supply
DC Power Supply
Power Consumption
Current Draw
(for an optional external
power supply unit;
Model S-240P)
Dimensions
Weight
Operation Temperature
Accessories
REAC Indicator
CTRL Indicator
ALARM Indicator
MUTE ALL OUTPUTS Indicator
+24 V (from optional external power supply unit : S-240P):
70 W
6 A
482.0 (W) x 386.7 (D) x 133.0 (H) mm
19 (W) x 15-1/4 (D) x 5-1/4 (H) inches
9.4 kg, 20 lbs 12 oz
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
Power Cord, REAC Connector Covers, Ferrite Cores,
Connector Guard, Screws for Connector Guard
Installation Manual
801 West Orchard Drive, Suite 3
Bellingham, WA 98225
TOLL FREE: 800.380.2580 • FAX: 800.634.8202
WWW.ROLANDSYSTEMSGROUP.COM