Edimax Technology ER-5398S User Manual

S
E
S
F
O
I
R
P
N
A
L
O
N
A
L
18-Port Rackmount
Ethernet Hub
ER-5398S
User ’ s Manual
Ethernet Hub
DIMAX
FCC COMPLIANCE STATEMENT
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the instructions provided with the equipment, may cause interference to radio and TV reception. The equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference in a commercial environment. However, there is no guarantee that interference will not occur in a particular installation.
If you suspect this equipment is causing interference, turn your hub on and off while your radio or TV is showing interference to determine the source of the interference.
You can try to correct the interference by one or more of the following measures:
1. Reorient the receiving radio or TV antenna where this may be done safely.
2. To the extent possible, relocate the radio, TV or the other receiver away from the equipment.
3. Plug the computer which has the equipment installed into a different power outlet so that equipment and the receiver are on different branch circuits.
If necessary, you should consult the place of purchase or an experienced radio/ television technician for additional suggestion.
CAUTION : The phone jack cannot be connected to telephone system.
Contents
Chapter 1 Introduction ....................................1
Chapter 2 Features & Specifications ..............2
Chapter 3 Package Contents ...........................3
Chapter 4 Physical Description .......................4
Chapter 5 Installation ......................................6
Chapter 6 Trouble-shooting ............................9
1
O
F
E
S
S
RESET
TURBO
O
F
E
S
S
L
E
S
L
E
S
Introduction
1
Congratulations on your purchase of Edimax’s 18-port rackmount Ethernet 10Base-T hub - ER-5398S. Designed to meet small and large 10Base-T network requirements, ER-5398S is built with 16 RJ-45 ports and two extra auto-detect AUI /BNC coaxial ports for cascading other 10Base-T hubs, mixing with thin or thick coaxial segments, or connecting to fiber backbone through fiber transceivers.
LEO PREDATOR
MHz
H.D.D.
LEO
60
POWER A B C D
LEO
18 PORT/10 Mbps ER-5398
R
10 BaseT Ethernet
Link/Rx
CollisionJabber
Partition
Power
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X 16MDI
DIMAX
18 PORT/10 Mbps ER-5398
R
10 BaseT Ethernet
Link/Rx
CollisionJabber
Partition
Power
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X16MDI-X9X 10X 11X 12X 16MDI
DIMAX
Figure 1-1 ER-5398S Topology
ER-5398S is rackmount size, 1U (1.75 inches) height, it can be installed on an industry standard 19 inches rack.
An uplink port located right next to the 16th RJ-45 port allows easy connection to other hubs or switches using regular straight-through cables as illustrated in Figure 1-2.
18 PORT/10 Mbps ER-5398
O
F
S
R
P
CollisionJabber
Power
10 BaseT Ethernet
Link/Rx Partition
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X
DIMAX
Uplink Port
16MDI
18 PORT/10 Mbps ER-5398
O
F
S
R
P
CollisionJabber
Power
10 BaseT Ethernet
Link/Rx Partition
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X
DIMAX
16MDI
Figure 1-2 Uplink to another hub
To accommodate various cabling requirements, ER-5398S can be easily integrated with other 10Base-T hubs in a central 19-inch wiring rack or be placed separately as stand-alone or distributed workgroup wiring center.
1
2
Features & Specifications
2
(1) Features
n Comply with IEEE 802.3 10Base-T, 10Base-2 and 10Base-5 Ethernet Standards. n Support sixteen RJ-45 connectors for 10Base-T connection and two auto-detect
10Base-2 BNC/10Base-5 AUI ports for mixed media network environment. n Built-in uplink port for easy connection to another hub using regular straight-
through cable. n Complete sets of LEDs provide an easy diagnostic on the hub’s and individual
port’s status.
n Standard 19" rackmount n Two-year warranty
(2) Specification
n Standards : IEEE 802.3 n 10Mbps Ports : RJ-45 x 16 & AUI /BNC x 2 n Hub LEDs : Power, Collision, Jabber n Port LEDs : RJ-45 - Link/Receive, Partition n Dimensions : 17.4 x 5.55 x 1.75 inches/442 x 141 x 44 mm n Weight : 4.04 lb./1.833kg n Power : external full-range, 110-240V AC, 50-60Hz n Operating Temperature : 32-1310F (0-550C) n Operating Humidity : 10-95% (Noncondensing) n Emission : FCC Class A & CE Mark
2
3
L
E
S
Package Contents
3
n 18-port rackmount Ethernet Hub n One power cord n Two T-Connectors n Rackmount accessories n User’s manual
18 PORT/10 Mbps ER-5398
O
F
S
R
P
CollisionJabber
Power
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X
10 BaseT Ethernet
DIMAX
Link/Rx Partition
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
Figure 3-1 Package contents
16MDI
3
N
N
L
4
Physical Description
4
(1) Panel
LED Panel
S
F
E
S
O
I
R
O
P
N
A
L
L
CollisionJabber
Power
Collision LED
Jabber
LED
Power LED
BNC
Ports
18 PORT/10 Mbps ER-5398
10 BaseT Ethernet
Link/Rx Partition
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
BNC Port
RJ-45 Connectors
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X
DIMAX
16MDI
Uplink Port
Link/Receive LED
E
S
F
S
O
I
R
O
P
N
A
L
CollisionJabber
Power
18 PORT/10 Mbps ER-5398
10 BaseT Ethernet
Link/Rx Partition
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
DIMAX
Partition LED
BNC 1BNC 2 AUI 1AUI 2
1 2 3 4 ON
AUI
Ports
Power 100-240VAC 1A
Figure 4-1 Panel description
4
(2) LED
LED Color Status Description
Power
Collision
Jabber Red
Link/Rx
(Link/Receive)
Partition
Green
Off
Yellow
Off
Off
Green
Flash
Off
Red
Off
Table 4-1 LED description
Lit
Lit
Lit
Lit
Lit
Power is supplied
No power
Collision detected in this segment
No Collision
Jabber detected in this segment
No Jabber
A valid link is established
Data packets received
No link is established
This port is patitioned
This port is working normally
5
5
L
F
E
S
S
DIMAX
Installation
5
1. Operating Environment
ER-5398S must be installed and operated within the limits of specified operating temperature and humidity (see previous section under Specifications). Do not place objects on top of the unit. Do not obstruct any vents at the sides of the unit. Do not position the hub near any heating source such as heater, radiator, or direct exposure to sun. Prevent entering of water and moisture into the unit. If necessary, use dehumidifier to reduce humidity.
2. Connecting to network devices with UTP cable
Connect one end of the network cable to any of the RJ-45 ports on the front panel of ER-5398S, and connect the other end of the network cable to the RJ-45 port of the network device. The network cables must comply with EIA/TIA 568 specifications and minimum Category 3 standard for 10Mbps data transmission. Maximum length between the hub and workstation is 100 meters (300ft). Once the network cable is connected on both ends and the attached network devices are powered on, the green LNK/Rx (Link Status) LED should be lit.
18 PORT/10 Mbps ER-5398
O
I
R
P
A
Link/Rx
CollisionJabber
Partition
Power
1X 2X 3X 4X 5X 6X 7X 8X 13X 14X 15X 16MDI-X9X 10X 11X 12X 16MDI
10 BaseT Ethernet
1 3 5 7 9
2 4 6 8 10 12 14 1611 13 15
Category 3
EIA/TIA 568
UTP Cable
100m
Figure 5-1 Connect the hub and network device
Network Adapter
10/100 FAST ETHERNET CARD FCC ID :
RTL8139
3. Uplink to Another Hub with UTP cable
Use uplink port to connect to another hub as illustrated in Figure 1-2. Connect one end of the network cable to the uplink port and connect the other end to any of the regular port in the other hub (except the uplink port). Connecting cable must comply with EIA/TIA 568 specifications and Category 3 standards to connect the hubs. Once the network cable is connected and both hubs are powered on, the green LNK/Rx (Link Status) LED should be lit. The maximum length of the uplink cable shall not exceed 100 meters (300 feet).
NOTE: Do not use the uplink port and 16th port at the same time.
6
4. Connecting network devices with coaxial cables
ER-5398S provides two auto-detect BNC/AUI coaxial ports, each can function as either BNC or as AUI but can be used at the same time. A set of configuration DIP switches are located between port 1 and port 2, they can be used to configure the coaxial port as auto-detect, BNC only or AUI only as illustrated in Figure 5-2 and Table 5-1.
NOTE : The default setting is auto­ detect mode.
1 2 3 4
ON
Port 1
Auto
AUI
BNC
AUI
Table 5-1 DIP Switch configuration for AUI/BNC port
Figure 5-2 DIP Switch for AUI/BNC port
Port 2
Auto BNC
AUI AUI
1
ON
ON OFF OFF
2
ON
OFF
ON
OFF
When using the BNC port, attach the T-connector to the BNC port on the rear panel and connect the coaxial cables to the both open ends of the T-connector as illustrated in Figure 5-3. If the ER-5398S is at either end of the coaxial segment, make sure terminate the open end of T-connector with a 50-ohm terminator. When using the AUI port, firmly attach the AUI transceiver to the AUI port and secure the transceiver into the socket. The AUI transceiver’s SQE (Heart Beat) should be set off.
Note : Do not connect coaxial cable directly to the BNC port without using T­connector.
BNC 1BNC 2 AUI 1AUI 2
1
2 3 4
ON
BNC 1BNC 2 AUI 1AUI 2
1
2 3 4
ON
Push to the righthand side to fix
Power 100-240VAC 1A
Figure 5-3 Connect the coaxial cables
Power 100-240VAC 1A
Figure 5-4 Connect the AUI transceiver
7
5. Connecting the power
Connect the power cord to the power socket on the rear panel of the unit. Connect the power cord to the power outlet and turn on power switch. The green Power LED on the front panel should be lit.
BNC 1BNC 2 AUI 1AUI 2
1 2 34 ON
Power 100-240VAC 1A
Figure 5-5 Connect the power
8
6
Trouble-shooting
6
1. Power LED is not lit
l Check if the power cord is properly connected to the power outlet and the hub. Make sure the power switch on the hub is turned ON.
2. LNK/Rx LED is not lit after connecting to an active workstation
l Check the power switch of the network devices attached to the hub; make sure they are turned ON.
l Check the network cable; make sure it is properly connected to the hub and the network device.
l Check the network cable; make sure the cable complies with EIA/TIA 568 specification. Use straight-through minimum Category 3 grade cables.
l Do not use uplink port to connect to a workstation.
3. Uplink (16th) port’s LNK/Rx LED is not lit after uplink to another hub
l Check the network cable; make sure it is properly connected to both hubs. One end of the cable should be connected to uplink port while the other end of the cable should be connected to a regular port. Do not connect the cable to both uplink ports.
l Check the network cable; make sure the cable complies with EIA/TIA 568 specification.
l Check the length of the network cable does not exceed 100 meters (300 feet). l Make sure both hubs are powered ON.
4. AUI/BNC ports do not transmit
l Check the DIP switch setting. l Check the AUI transceiver; make sure the SQE is set at OFF. l Check the attachment of coaxial cable; make sure there’s no loose connection. l Check the coaxial cable; make sure the segment is terminated with 50-ohm
terminator.
9
5. Partition LED is lit
l Check the connected devices. The hub will automatically partition a defective Ethernet device which causing excessive errors.
6. Collision LED is constantly flashing
l Remove all the network cables; connect the cables back one by one to isolate the source of the collision.
l Check the network cable, inferior cable quality will result in excessive collision and error packets.
7. Jabbler LED is constantly flashing
l Check the connected devices. Remove all the network cables; connect the cables back one by one to isolate the source of the jabber.
[!] Contact your dealer if problem persist.