ES-3305P V3: 5-Port Fast Ethernet Desktop Switch
ES-3308P V3:8-Port Fast Ethernet Desktop Switch
Package Contents
Before you start using this switch, please check if there is anything missing in the
package, and contact your dealer to claim the missing item(s):
Fast Ethernet Desktop Switch
Quick Installation Guide
Power Adapter
Top Panel
5-Port Fast Ethernet Desktop Switch:
2
8-Port Fast Ethernet Desktop Switch:
LED Name
Light
Status
Description
PWR
On
Switch is on
Off
Switch is off
LNK/ACT
On
Corresponding port is connected
Off
Corresponding port is not connected
Flashing
Corresponding port is active and transferring
/receiving data.
LNK/ACT LEDs 1 - 8
PWR LED
5VDC Power
RJ-45
Ports 1 - 5
RJ-45
Ports 1 - 4
5VDC Power
RJ-45 Ports 5 - 8
LED Status:
Side Panel
5-Port Fast Ethernet Desktop Switch
8-Port Fast Ethernet Desktop Switch
3
Operating Environment
This switch must be installed and operated within the limits of the specified
operating temperature 0 - 40°C (32 - 104°F) and humidity (10 - 90%
non-condensing).
- Do not place objects on top of the unit.
- Do not obstruct any vents at the sides of the unit.
- Do not position the unit to any heating source such as a heater, radiator or in
direct exposure to sun.
- Take care to ensure the unit does not come into contact with water. Consider
using a dehumidifier to reduce humidity and prevent moisture entering the
unit.
Connecting to network devices
The RJ-45 ports on the switch support Auto-MDI/MDI-X which allows both
straight-through or cross-over type cables to connect this switch to a workstation
or switch.
Connect one end of the network cable to the RJ-45 port on the side panel, and
connect the other end of the network cable to the RJ-45 port on the network
device. Follow the same procedure to connect all RJ-45 ports of the switch.
The UTP network cables must comply with EIA/TIA 568 specifications and
Category 5 standard for data transmission. The maximum length for a UTP cable
segment between the switch and connected devices is 100 meters (300ft).
Once the network cable is connected to both ends and the attached network
device is powered on, the green LNK/ACT LED should be lit.
4
Connecting the power
Connect the power adapter to the power connector of the unit; the green power
LED on the front panel should be lit.
TROUBLESHOOTING
1. Power LED is not lit
Check if the power cord is properly connected to the external power adapter
and the power source. Make sure the DC power jack is firmly plugged into the
power socket of the switch.
2. Link/Activity (LNK/ACT) LED is not lit when connected to devices
- Ensure that the network device attached to the switch is switched on.
- Check the network cable; ensure it is properly connected to the switch and the
network device.
- Check the network cable; ensure the UTP cable complied with EIA/TIA 568 and
Category 5 specifications.
[!] Contact your dealer if problems persist.
5
COPYRIGHT
Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this
publication may be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language or computer language, in any form or by
any means, electronic, mechanical, magnetic, optical, chemical, manual or
otherwise, without the prior written permission from Edimax Technology Co.,
Ltd.
Edimax Technology Co., Ltd. makes no representations or warranties, either
expressed or implied, with respect to the contents hereof and specifically
disclaims any warranties, merchantability, or fitness for any particular purpose.
Any software described in this manual is sold or licensed as is. Should the
programs prove defective following their purchase, the buyer (and not this
company, its distributor, or its dealer) assumes the entire cost of all necessary
servicing, repair, and any incidental or consequential damages resulting from any
defect in the software. Edimax Technology Co., Ltd. reserves the right to revise
this publication and to make changes from time to time in the contents hereof
without the obligation to notify any person of such revision or changes.
The product you have purchased and the setup screen may appear slightly
different from those shown in this QIG. For more information about this product,
please refer to the user manual on the CD-ROM. The software and specifications
are subject to change without notice. Please visit our website www.edimax.com
for updates. All brand and product names mentioned in this manual are
trademarks and/or registered trademarks of their respective holders.
Edimax Technology Co., Ltd.
Add: No. 3, Wu-Chuan 3rd Rd., Wu-Ku Industrial Park, New Taipei City, Taiwan
Tel: +886-2-77396888
Email: sales@edimax.com.tw
6
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio technician for help.
FCC Caution
This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible
for compliance could void the authority to operate equipment.
Federal Communications Commission (FCC) Radiation Exposure Statement
This equipment complies with FCC radiation exposure set forth for an uncontrolled environment. In order to avoid the
possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less
than 2.5cm (1 inch) during normal operation.
Federal Communications Commission (FCC) RF Exposure Requirements
This EUT is compliance with SAR for general population/uncontrolled exposure limits in ANSI/IEEE C95.1-1999
and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65
Supplement C. The equipment version marketed in US is restricted to usage of the channels 1-11 only.
R&TTE Compliance Statement
This equipment complies with all the requirements of DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND THE
COUNCIL of March 9, 1999 on radio equipment and telecommunication terminal equipment and the mutual
recognition of their conformity (R&TTE). The R&TTE Directive repeals and replaces in the directive 98/13/EEC
(Telecommunications Terminal Equipment and Satellite Earth Station Equipment) As of April 8, 2000.
Safety
This equipment is designed with the utmost care for the safety of those who install and use it. However, special
attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment.
All guidelines of this and of the computer manufacture must therefore be allowed at all times to ensure the safe use of
the equipment.
EU Countries Intended for Use
The ETSI version of this device is intended for home and office use in Austria, Belgium, Bulgaria, Cyprus, Czech,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Turkey, and United Kingdom. The ETSI
version of this device is also authorized for use in EFTA member states: Iceland, Liechtenstein, Norway, and
Switzerland.
EU Countries Not Intended for Use
None
7
EU Declaration of Conformity
English: This equipment is in compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC, 2009/125/EC, 2006/95/EC, 2011/65/EC.
French:Cet équipement est conforme aux exigences essentielles et autres dispositions de la directive
1999/5/CE, 2009/125/CE, 2006/95/CE, 2011/65/CE.
Czechian:Toto zařízení je v souladu se základními požadavky a ostatními příslušnými ustanoveními
At the end of its serviceable life, this product should not be treated as household or general waste. It should
be handed over to the applicable collection point for the recycling of electrical and electronic equipment, or
returned to the supplier for disposal.
8
Declaration of Conformity
We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the
equipment described below complies with the requirements of the European R&TTE
directive.
Equipment
:
5 / 8-Port Fast Ethernet Desktop Switch
Model No.
:
ES-3305P V3 / ES-3308P V3
The following European standards for essential requirements have been followed:
EMC
:
EN 55022:2010
EN 55024:2010
EN 61000-3-2:2006 + A2:2009
EN 61000-3-3:2008
Edimax Technology Co., Ltd.
No. 3, Wu Chuan 3rd Road,
Wu-Ku Industrial Park.
New Taipei City, Taiwan
Date of Signature:
March, 2015
Signature:
Printed Name:
Albert Chang
Title:
Director
Edimax Technology Co., Ltd.
9
1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.