EdilKamin RADA AIR TIGHT C, VYDA AIR TIGHT Installation, Use And Maintenance Manual

PELLET STOVE
RADA AIR TIGHT C
EN Installation, use and maintenance page 2
CONTENTS
Introduction and readers of this manual 3
Safety information 4
Dimensions 5
Technical data 6
Unpacking 7
Installation 9
Cladding 14
Instructions for use 17
Maintenance 28
Troubleshooting 31
The original language of this edition is Italian
ENGLISH
2
The undersigned company, EDILKAMIN S.p.A., with registered office in Via Vincenzo Monti 47 - 20123 Milan (Italy) - Italian Tax ID VAT NO. 00192220192
PELLET STOVES, bearing the EDILKAMIN brand, called RADA AIR TIGHT C
SERIAL NO.: Rating plate reference RADA AIR TIGHT C Performance declaration (DoP - EK n° 177)
Moreover, the company hereby declares that: the RADA AIR TIGHT C wood pellet stoves satisfy the requirements of the following European directives: 2014/35/EC - Low Voltage Directive 2014/30/EC - Electromagnetic Compatibility Directive
USER/INSTALLER
Dear Sir/Madam
We thank you for and congratulate you on choosing our
product. Before using it, we would ask you to read this
manual carefully, so that you can make the most of all its
functions in total safety.
This manual is an integral part of the product. We ask you
to keep it for the entire lifetime of the product. If you lose it,
you can request a copy from your dealer or download it from
www.edilkamin.com.
Readers of the manual
This manual is addressed to:
those who use the product at home (“USER”);
the technician who will install the product
(“INSTALLER”).
The target person of each page is indicated in a band at the
bottom of the page (USER or INSTALLER).
General information
After unpacking the product, check the condition and
completeness of the contents.
In the event of error, immediately contact the retailer where
the purchase was made, providing him with a copy of the
warranty booklet and sales receipt.
The appliance must be installed and operated in compliance
with local and national law and European regulations. For the
installation, and for anything not specifically indicated in the
manual, observe local regulations.
The diagrams provided in this manual are for illustration
purposes only: they do not always strictly refer to your
specific model, and are not binding in any way.
Product identification and warranty.
The product is uniquely identified by a number, the
“counterfoil”, which is indicated on the warranty certificate.
Please keep:
• the warranty certificate accompanying the product
• the purchase receipt given to you by the retailer
• the declaration of conformity given to you by the installer.
The warranty conditions are given in the warranty certificate
accompanying the product.
First ignition is required, in Italy, by an authorised
technician in accordance with UNI 10683, and is
recommended in all countries to ensure best results from
the product.
This consists of:
checking the installation documents (declaration of
conformity) and the quality of the installation itself
calibrating the product to suit its actual application
providing explanations to the end user and issuing
the complementary documentation (first ignition -
commissioning certificate)
Having the appliance commissioned properly ensures that it
will operate to best effect and in complete safety.
First ignition is required for activation of the Edilkamin
manufacturer warranty. The warranty is only valid in the
country where the product was bought.
If the appliance is not commissioned by an authorised
technician, Edilkamin will not provide warranty service. See
the warranty booklet for details. The above terms do not
affect the dealer’s legal responsibility for the legal warranty.
ENGLISH
3
MEANING OF SYMBOLS
In some parts of the manual the following symbols are used:
PLEASE NOTE: carefully read and understand the message in question, since failure to follow the instructions in it could cause serious damage to the product and put the safety of those using it at risk.
INFORMATION:
failure to comply with these requirements will compromise product use.
OPERATING SEQUENCE:
follow the instructions for the operations described.
The warranty, however, covers only demonstrable
manufacturing defects and not, for instance, problems
resulting from improper installation or calibration.
USER/INSTALLER
SAFETY INFORMATION
• The product is not designed for use by people, including children, with limited physical, sensory and mental abilities.
• The appliance is not designed for cooking purposes.
• The appliance is designed to burn UNI EN ISO 17225-2 category A1 wood pellets, in the amounts and manner described in this manual.
• The appliance is designed for indoor use and in areas with normal humidity conditions.
• Keep the product in a dry place out of the weather.
• For the legal and company warranties, refer to the warranty certificate inside the product: specifically, neither Edilkamin nor the retailer are liable for damage resulting from incorrect installation or maintenance.
Safety risks may be caused by:
• Installation in non-suitable settings, in particular those that are subject to fire risks. DO NOT INSTALL THE PRODUCT IN AREAS SUBJECT TO THE RISK OF FIRE.
• Contact with fire and hot parts (e.g. glass panel and pipes). DO NOT TOUCH HOT PARTS and, when the stove is switched
ENGLISH
off and still hot, always wear the glove
4
supplied.
• Contact with live electrical equipment (internal). DO NOT ACCESS THE INTERNAL ELECTRICAL EQUIPMENT WHILE THE APPLIANCE IS POWERED ON. Electrocution hazard.
• Use of improper ignition aids (e.g. alcohol). DO NOT IGNITE OR BOOST THE FLAME WITH FLUID SPRAYS OR A FLAME TORCH. Serious risk of burns, damage and injury.
• Use of fuel other than wood pellets. DO NOT BURN WASTE MATTER, PLASTIC OR MATERIALS OTHER THAN WOOD PELLETS IN THE COMBUSTION CHAMBER. The product may become soiled, the flue may catch fire, and environmental damage may ensue.
• Cleaning the combustion chamber when hot. DO NOT CLEAN WITH A VACUUM CLEANER WHEN HOT. You could damage the vacuum-cleaner and risk the emission of smoke in the room.
• Cleaning the smoke duct with cleaning products. DO NOT CLEAN THE PRODUCT WITH FLAMMABLE PRODUCTS. Risk of fire or blowback.
• Cleaning the glass pane while hot or
with unsuitable cleaning products. DO NOT CLEAN HOT GLASS WITH WATER. ONLY USE RECOMMENDED GLASS CLEANING PRODUCTS. Risk of cracking and permanent, irreparable damage to the glass.
• The storage of flammable materials at a distance which is less than the safe distances listed in this manual. DO NOT PLACE LAUNDRY ON THE APPLIANCE. DO NOT PLACE DRYING RACKS WITHIN THE SAFETY CLEARANCE. Keep flammable fluids away from the appliance. Fire hazard.
• Blocking the aeration vents and air intakes in the room. DO NOT BLOCK THE AERATION VENTS OR FLUE. Risk of smoke returning into the room with consequent damage and injury.
• Use of the product as a support or ladder. DO NOT CLIMB ONTO THE PRODUCT OR USE IT AS A SUPPORT. Risk of damage and injury.
• Use of the stove with the combustion chamber open. DO NOT USE THE PRODUCT WITH ITS DOOR OPEN.
• Incandescent material may come out from the open door. DO NOT throw incandescent material outside the appliance. Fire hazard.
• Use of water in case of fire. CALL THE AUTHORITIES if a fire breaks out.
Switch on the product only after complete installation including coverings. Risk of electric shock from live device parts.
If you have doubts, please do not take any action, but contact the retailer or the installer.
For reasons of safety, read the user instructions included in this manual.
USER/INSTALLER
DIMENSIONS
RADA AIR TIGHT C - DIMENSIONS (cm)
3
112,5
110
Ø 8 cm smoke outlet Ø 13 cm coaxial
5
55
35
Ø 6 cm
ducting
11,5
Ø 6 cm
ducting
(optional)
15 12,5 23
ENGLISH
5
55
USER/INSTALLER
TECHNICAL DATA
TECHNICAL CHARACTERISTICS in accordance with EN 14785
RADA AIR TIGHT C
Nominal power Reduced power
Available power 12,8 * 2,8 kW
Efficiency 91,3 93 %
CO emissions at 13% O
2
Fumes temperature 186 69 °C
Fuel consumption** 2,9 0,6 kg/h
Tank capacity 24 kg
Draw 11 9 Pa
Autonomy 8 40 ore
Heatable volume ** 335 m
Fume duct diameter 8-13 F mm
Weight including packaging 160 kg Energy efficiency class according to UE 2015-
1186 regulation (Class A++/G)
0,007 0,023 %
A+
3
ENGLISH
6
* Achieved power if installed with ducting.
*A calorific value of 4.8 kW/Kg has been used to calculate consumption.
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
TECHNICAL DATA FOR SIZING THE FLUE
which must in any case satisfy the requirements of this sheet and the installation instructions
Nominal power Reduced power
Fumes temperature at smoke outlet 223 83 °C
Minimum draw 0,01 Pa
Fumes 6,3 4,1 g/s
Typ DIBt CC 50
ELECTRICAL SPECIFICATIONS
Power supply 230 Vac +/- 10% 50 Hz Mean absorbed power 115 W Reduced absorption Power 52 W Stand by absorption Power 4 W Absorbed power on ignition 365 W Remote control frequency (provided) 2,4 GHz Protection rating Fuse 4 AT, 250 Vac 5x20
EDILKAMIN s.p.a. Reserves the right to modify the product without notification in the inte­rests of improvement.
USER/INSTALLER
UNPACKING
UNPACKING AND PREPARATION
Packing employed materials are not toxic or harmful and do not require specific disposal. Storage, disposal or possible recycling must be provided by the user in compliance with relative applicable laws.
Each handling operation must be performed in vertical position by appropriate means and in accordance with current safety regulations. Do not overturn the packaging.
PACKAGING
Two parcels are included:
• One with the stove structure
• One with coatings
• Stove will include:
• Warranty certificate
• Glove
• User manual
• Power cable
• Remote control
• Coatings fitting small parts
• Hearth door opening and closing cold hand (removable)
ENGLISH
7
INSTALLER
UNPACKING
DO NOT REMOVE THE PRODUCT FROM THE PALLET BEFORE OPENING THE DOOR AND LOOSENING THE SCREWS.
HOW TO REMOVE THE STOVE FROM THE PALLET
1. Remove the sides loosening the upper screws
2. Open the door and remove the fan protection grid
3. Remove the 4 screws tightening the stove base to the pallet
4. Fit back the fan protection grid
Screws to loose for sides removing
ENGLISH
8
Screws
THE DRAWINGS ARE FOR GUIDANCE ONLY, USEFUL FOR THE INSTALLATION, BUT THEY MAY NOT REFER TO THE SPECIFIC MODEL.
INSTALLER
INSTALLATION
REMARKS ON INSTALLATION
Note that:
• installation must be carried out by authorised technical personnel; the appliance must be installed and operated in compliance with local and national law and European regulations. The Italian reference standard is UNI 10683; in France one must follow the instructions in the DTA (Document Technique d’Application Référence Avis Technique), www.cstb.fr
• if installed in a condominium, the appliance must be approved by the administrator;
• if installed in public premises, check and follow local regulations for this type of installation. Here are a few general instructions, although these do not obviate the need to comply with local regulations and do not affect the installer’s liability for the installation. Remember that Rada Air Tight C is sealed, in other words, if it is installed correctly with the air inlet pipe connected to the outside, it takes the majority of the air from the outside. For different countries, check if there are particular installation conditions allowed for sealed stoves.
Checking the suitability of the installation space
• The room must have a volume of at least 30 m
3
• The floor must be able to bear the weight of the product and its accessories* (see the note in the paragraph on the heat protection)
• Level the appliance
• Pursuant to Standard 10683 rev. 2012 point 6.3, in Italy you can also install the appliance in bedrooms or in rooms which already include a product that takes air from it for combustion, provided that the air inlet is connected to the outside
• Do not install the product in spaces where there is a risk of fire or explosion
• In Italy, check the compatibility pursuant to UNI 10683 and UNI 7129 in the presence of gas fired products.
Protection from heat and safety clearances
The surfaces of the building adjacent to the product must be protected against overheating. The insulation to be used will depend on the type of surface in question.
The appliance must be installed in accordance with the following safety instructions:
- minimum clearance at the sides 15 cm and back of 10 cm from flammable materials
- no flammable materials may be kept closer to the front of the appliance than 80 cm. If connected to a wooden or otherwise flammable wall, the flue must be appropriately insulated.
If installed on a flammable or combustible floor, or which is not capable of bearing its load*, use steel or glass plates under the stove to distribute the load. Contact the retailer for this type of optional.
Positioning the product
The product is designed to operate in all climate conditions. In special circumstances, such as strong wind, the safety devices may intervene to switch the appliance off. Contact the authorised Edilkamin Technical Assistance Centre.
ENGLISH
9
INSTALLER
INSTALLATION
INSTRUCTIONS FOR THE SMOKE DISCHARGE WITH OR WITHOUT CONCENTRIC PIPE
FLUE SYSTEM (fumes duct, flue and chimney pot)
This chapter has been drawn up pursuant to European regulations EN 13384, EN 1443, EN 1856 and EN
1457. The installer must observe both these and any other local regulations. This manual does not in any way substitute such regulations. The product must be connected to a flue system which ensures that the fumes produced by combustion are expelled in complete safety.
Before positioning the appliance, the installer must check that the flue is suitable.
FUMES DUCT, FLUE
The fumes duct (which connects the combustion chamber smoke outlet with the flue) and the flue itself must, among other regulatory requirements:
• receive the fumes from a single product (the outlets of multiple appliances may not be conveyed into
ENGLISH
10
a single flue)
• be routed vertically for the most part
• have no downwards sloping sections
• preferably have a circular internal cross section, or with a ratio of the sides of less than 1.5
• terminate at roof level with a proper chimney pot: the flue may not discharge directly on the wall or into an enclosed space, even if the space in question is open to the sky
• be made of material with rated fire reaction class A1 as per UNI EN 13501 or analogous national regulations
• be certified, with a chimney plate if metal
• be of uniform cross section or vary in cross section only immediately after the outlet, not at some midpoint of its length.
THE FUMES DUCT
• Further to the general prescriptions for the fumes duct and flue, the fumes duct:
• may not be made of flexible metal material
• must be insulated, if routed through unheated areas or outdoors
• must not be routed through rooms where the installation of combustion heat generators is prohibited or there is risk of fire, or that cannot be inspected
• must enable the recovery of soot and be open for inspection
• must have a maximum of 3 bends with a maximum angle of 90°
• if there is a horizontal section, it can have a maximum length of no more than 3 metres, depending on the draw. Note, in any case, that long sections encourage the accumulation of dirt and are harder to keep clean.
THE FLUE:
Further to the general prescriptions for the smoke duct and flue, the flue:
• must only be used for discharging fumes
• must be correctly sized to satisfy the requirements for fume discharging (EN 13384-1)
• should preferably be insulated, in steel with a circular internal section. If rectangular, the corners must have a radius of not less than 20 mm, with aratio of the internal dimensions of <1.5
• must normally be at least 1.5 metres in vertical length
• must have a constant cross section
• must be waterproof and thermally insulated to ensure a good draw
• preferably provide a collection chamber for unburnt residues and condensates
• if pre-existing, must be clean, to prevent fire hazards
• in general, we recommend fitting a tube inside the existing masonry chimney if its diameter is greater than 150 mm.
INSTALLER
INSTALLATION
INTUBATED SYSTEM:
Further to the general prescriptions for the fumes duct and flue, the intubated system:
• must operate in negative pressure;
• must be open to inspection;
• must observe local regulations.
THE CHIMNEY POT (In every country and specially in France, check on the specific waiver conditions)
• must be anti-downdraught
• must have an internal cross section equivalent to that of the flue and a fumes outlet at least double that of the interior of the flue
• for dual flues (which should be spaced at least 2 m apart) the chimney pot receiving the fumes from the solid fuel appliance or that from the higher storey, must be at least 50 cm higher than the other
• it must extend beyond the back flow zone (in Italy, refer to UNI 10683 point 6.5.8.)
• it must allow for maintenance of the chimney.