EDI P103 M7 Backup Datasheet

Page 1
Performance Controls
Features
24" rack mount
Simple user assignable controls
Available in 60 or 120 channel capacities
Signal light indicates data signal in process
Overtemp signal light
Calibration Adjustments Status Indicators Analog Backup
Power phase indicator lights
Supports USITT DMX-512 Digital, AMX 192, RS422, fiber-optic or 0 - +10 VDC Ana-
log inputs
Simultaneous processing of digital and analog signals
Mark VII Analog Backup
Description
Analog Backup provides easy access and control of user assignable groups of lights or dimmers. This allows easy access to presets by general users without requiring a complete working knowledge of the control console.
Analog Backup offers a simple 10-channel control matrix. A single dimmer or group of dimmers can be assigned to a control channel by means of a wire pin matrix patch. Commonly controlled dimmer groups can be assigned to ten slide potentiometers with a master and On/Off control located at the Stage Manager's panel.
Specifications
1. The plug-in control module shall be a self-contained unit which will slide into the front of the dimmer bank.
2. The control module shall properly receive USITT DMX-512 digital multiplex, AMX-192 analog multiplex, or RS422 digital multiplex, fiber optic or 0-10 Volt analog signals. Digital signals shall termi­nate in 5-pin XLR-type connectors. Fiber optic transmissions shall terminate in an optical coupler. Analog controls shall terminate in a 25-pin D-style connector. The multiplex format may be changed by a single front-panel mounted switch.
3. A yellow indicator shall illuminate upon receipt of a valid digital signal. A momentary interruption of a digital signal shall not affect dimmer output.
4. The dimming system shall be able to operate simultaneously on a multiplex signal and analog 0-10 volt signal. The analog signal shall activate the backup matrix patch of independently assigned dimmers to the selected intensities set by the controller. Should the DMX signal ports fail, the analog backup shall operate as a stand­alone controller. The analog backup shall have the capacity for multiple input on a highest-takes-precedence basis. Systems elec­tronics without this capacity shall not be considered equal.
5. The module shall illuminate a pilot light for each power phase dur­ing operation. Input power to the control module shall be breakered and fused.
6. All dimmer control electronics shall be contained on a double­sided, through-hole plated fiberglass circuit board.
7. The control module shall be a labeled, recognized component of Underwriters Laboratory.
8. The unit shall be the Multi-Link series as manufactured by Elec­tronics Diversified, Inc., Hillsboro, Oregon 97214.
Riser Diagram
Dimmer Bank
Analog Backup
Data Line to Control
RCC (5XLR)
Stage Manager’s Panel
(10 Channel Control Station)
Analog (15D)
Booth Control Console
Job Number: Customer: Approval Stamp: Job Name: P.O.:
Electronics Diversified, Inc. PRODUCT DATA SHEET 1675 N.W. Cornelius Pass Road l Hillsboro, Oregon 97124 U.S.A. P103
Phone: (800) 647-2690 l FAX: (503) 629-9877 l Web Site: www.edionline.com
Specifications subject to change without notice. Specification applicable to standard products only. ©1998 Electronics Diversified, Inc. All rights reserved. Printed in USA. 0703