Pulse Pool Pump Installation & Operating Instructions Part # 10-0030 Nov 2012 Page 2
Table of Contents
GENERAL INFORMATION………………………………
3
INSTALLATION………………………………………......
3
ELECTRICAL CONNECTION…………………………....
4
OPERATION PRIMING …………………………… ….
4
HAIR AND LINT POT MAINTENANCE…………....
5
GENERAL MAINTENANCE ………………………….
6
TROUBLE SHOOTING GUIDE………………………….
7
WARRANTY INFORMATION…………………………..
8
PULSE SPECIFICATIONS…………………………………..
9
SPARE PARTS…………………………………………….
10
NOTES……………………………………………………..
11
Pulse Pool Pump Details
Model Number:
Serial Number:
Date of Purchase:
Invoice Number:
Pulse Pool Pump Installation & Operating Instructions Part # 10-0030 Nov 2012 Page 3
General
The Pulse series pool pump has been specifically designed to operate todays swimming pools, its high performance and high head flow characteristics will ensure that the Pulse pool pump will operate with all your ancillary equipment including chlorinators, heaters, in floor cleaners and pool cleaners.
Installation of the Pulse Pool Pump
Edgetec Systems Pty Ltd has applied the latest CAD design software in designing your Pulse Pool Pump to ensure that you have many years of trouble free operation. Here are some simple installation rules that should be followed when installing the Pulse pool pump;
1. Care should be taken to position the pump so that it has adequate drainage. Ensure the
motor cannot become wet or flooded and the pump location should be well ventilated. The pump should be protected from direct sunlight and weather.
2. Ensure that the pump is secured onto a stable base. The pump mounting foot has
mounting points where the pump can to be bolted to the base to prevent movement.
3. The pump foot has an anti-vibration pad moulded into the base to minimise noise and
vibration. Failure to secure the pump to the base securely may cause damage and void the warranty.
4. The pump must be accessible for maintenance and be easily removed for service. Ensure
that you allow enough area around the hair and lint pot basket for removal and cleaning.
5. The pump suction line requires a minimum of 50mm PVC pipe and should be kept as short
as possible with the minimum number of elbows and bends and no air trap for optimum performance. The suction line must be installed below the water level until just in front of the pump location and the vertical riser used to reach the pump inlet. Note: Wear
protective gloves when using PVC glue and solvents and always allow 24 hours to dry before starting the pool pump.
6. The suction and return pipe work should be self-supported so that no strain from the
pipework loads up the pump barrel unions. The pump should not be suspended by the pipe work or other equipment as this will cause leaks and eventual damage to the pump. Only use the barrel unions supplied with the pump, barrel unions only require to be hand tight, do not use tools to tighten the barrel union nuts.
7. If the pump is installed below the water level - isolation valves must be fitted to the
suction and return lines.
8. Pump installations that are 500mm or more above the water level will require a foot valve
at the pool or a check valve in the suction line.
9. Water temperature must not exceed 45°.
Pulse Pool Pump Installation & Operating Instructions Part # 10-0030 Nov 2012 Page 4
Electrical Connection
1. IMPORTANT! - The electrical installation must be performed by a licensed electrician and
must conform to all national, state and local codes. Australian Wiring Rules AS3000
2. The PULSE pump must be supplied through a residual current device (RCD) with a rated
residual operating current of 30mA.
3. If the supply cord is damaged it must be replaced by Edgetec Systems or its service agent or
a suitably qualified person.
Operation-Priming
The Pulse series pool pump has been designed to prime and re prime as long as the hair and lint pot bowl is full of water and there is adequate supply from the suction points.
Priming/Start up
1. If the pump is installed above the water level and the hair and lint pot has no water in the
bowl, close off the valve in the suction line (if fitted), remove the hair and lint pot lid, and fill the bowl with water and replace the hair and lint pod lid ensuring that its fitted correctly.
2. If the pump is installed below the water level, open the valves and you should see the water
flow freely into the hair lint pot bowl.
3. Switch the pool pump on.
4. The pump should now be primed and running; however, on some installations the priming
time may alter depending on the elevation and the length of pipe on the suction line.
5. If after around 90 seconds the pump has not primed switch the pump off and repeat step 1.
If after a number of attempts you still cannot prime the pump check your connections for any leaks, it may be necessary to fit a foot or check valve to obtain prime.
6.
WARNING
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
!
WARNING
Never run your pool pump without water as this can cause serious damage to the mechanical seal which may cause the pool pump to leak.
Running the pump without water will void your warranty.
!
WARNING
FOR YOUR SAFTEY: This Product must be installed and serviced by a qualified service technician. Improper Electrical installation can create dangerous electrical hazards which could cause death, serious injury or property damage. Improper installation will void the warranty.