EDGETEC SYSTEMS PTY LTD Part # 9-2100 FEB2017 www.edgetec.net
Table of Contents
Pro-Tec Accessories .................................................................................................... 3
Correct Spa Bath Pump Installation ......................................................................... 4
Incorrect Spa Bath Pump Installation ...................................................................... 5
Correct Mounting on External Wall. ......................................................................... 6
Air Tube Connections – AH and XH Models ........................................................... 7
Touch Pad Connections ST and ET Models ............................................................. 7
Activating Air Bleed .................................................................................................... 8
AIR BLEED – INTERNAL INSTALLATION ........................................................................ 8
TriFlo Spa Bath Pump .................................................................................................. 9
Installation Instructions (refer page 4, 5 & 6) ........................................................ 11
Electrical Connection .............................................................................................. 12
Trouble Shooting Guide ........................................................................................... 14
TriFlo Technical Data ................................................................................................ 15
Edgetec Product Warranty ..................................................................................... 16
Terms & Conditions ................................................................................................... 16
Commercial Installation ........................................................................................... 16
TriFlo Pump Details
Model Number:
Serial Number:
Date of Purchase:
Invoice Number:
EDGETEC SYSTEMS PTY LTD Part # 9-2100 FEB2017 www.edgetec.net
Easy To Install. Complete With Wall Brackets & Base. Pro-Tec Pump Cover Reduces Noise
Level. Left or Right Hand Mount – Neutral Merino Colour-Part #6400
Pro-Tec Cover Plate
Easy to Install. Can be fitted during installation or fitted after installation. Complements ProTec Pump Cover above and can be painted to match house décor -Part #6420
Pro-Tec Drain Tray – Internal Installation
Easy To Install. Protects indoor installations from water damage should any small drip from
the mechanical seal occur due to normal wear -Part #6450
Pump Mounted on Drain Tray
EDGETEC SYSTEMS PTY LTD Part # 9-2100 FEB2017 www.edgetec.net
Correct Spa Bath Pump Installation
Use 40mm or 25mm UPVC Pressure Pipe for plumbing installation,
40mm pipe is preferred for both the suction and return lines.
IMPORTANT REQUIREMENT FOR PUMP SERVICE:
Pump installation must provide access for pump removal.
To allow for pump removal a serviceman must be able to reach the barrel unions.
For under the hob installation- an access panel must be provided on the installation
Return Line
Minimum 1:100 Gradient (0.5°)
Return Line
Minimum 1:100 Gradient (0.5°)
Return Line
Minimum 1:100 Gradient (0.5°)
Suction Line
Minimum 1:100 Gradient (0.5°)
Suction Line
Minimum 1:100 Gradient (0.5°)
Water Level Minimum 50 mm Above Spa Jets
Top Outlet Installation-Please note the Air
Bleed cannot be activated in this installation.
Suction Line
Minimum 1:100 Gradient (0.5°)
EDGETEC SYSTEMS PTY LTD Part # 9-2100 FEB2017 www.edgetec.net
Incorrect Spa Bath Pump Installation
Use 40mm or 25mm UPVC Pressure Pipe for plumbing installation,
40mm pipe is preferred for both the suction and return lines.
IMPORTANT REQUIREMENT FOR PUMP SERVICE:
Pump installation must provide access for pump removal.
To allow for pump removal a serviceman must be able to reach the barrel unions.
For under the hob installation- an access panel must be provided on the installation.
INCORRECT PIPEWORK
LOOP-PUMP WILL AIRLOCK
PUMP CANNOT PRIME
PUMP MOUNTED TO HIGH
PUMP CANNOT PRIME
PUMP MOUNTED TO LOW
PUMP CANNOT DRAIN