Edge Lighting Zzz Lamp User Manual

© 2011 Edge Lighting. All Rights Reserved.
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613 www.edgelighting.com info@edgelighting.com
FJ-ZL-_
Installation Instructions for Fast Jack Zzz Lamp Pendant
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electrical shock, exposure to excessive UV radiation, or injury to persons:
- Use this fixture indoors only.
- Do not look directly at the lamp while the fixture is on.
- RISK OF FIRE: Use only the type of lamp and maximum wattage indicated in this instruction manual.
- Never cover the halogen lamp with anything other than a lamp shield provided by Edge Lighting and never place flammable material close to the fixture.
- Never turn the fixture on and off by connecting and disconnecting the halogen lamp.
- Do not touch the fixture head, shade or lamp shield while the fixture is on. These surfaces may be VERY HOT.
- Do not touch lamp at anytime. Use a soft cloth instead as oil from skin may damage lamp.
- It is normal for a new halogen lamp to produce minor smoke when first turned on.
- Do not operate the luminaire with a missing or damaged shield.
- Turn power off and allow to cool before replacing lamp.
IMPORTANT INFORMATION
- This product is ETL listed for indoor dry locations and approved to be used at any height above the finished floor.
SAVE THESE INSTRUCTIONS!
904-FJ-ZL-01
Adjust the Fixture Height
A
H
1
1: Cut the coaxial cable to the desired height (H) with a sharp
cutter. The overall fixture height is measured from the bottom of the glass shade to the end of the coaxial cable.
1
B
2: Loosen the M4 set screw on base of the coaxial fixture connector with the 2mm Allen wrench provided. Do not remove this set screw.
2MM ALLEN WRENCH
M4 SET SCREW
COAXIAL FIXTURE CONNECTOR
4: Use the #12 gauge hole of the AWG wire strippers to strip 1" of the insulation cover from the end so that the bare coaxial cable is exposed.
2
3
1.5MM ALLEN WRENCH
M3 SET SCREW
3: Remove the M3 set screw on tip of the connector with the
1.5mm Allen wrench provided.
C
INSULATION
4
1"
WIRE STRIPPER
COAXIAL CABLE
D
CONICAL NIPPLE
7: Feed the inner coaxial cable along with strain relief tube into the coaxial fixture connector.
STRAIN RELIEF TUBE
5
INSULATION
OUTER METAL JACKET
6
5: Feed the coaxial cable through the conical nipple and flared
side of the strain relief tube. Slide the conical nipple down the coaxial cable. Slide the strain relief tube against the insulation.
6: Use the #14 gauge hole of the AWG wire strippers to strip the outer metal jacket exposed behind the strain relief tube.
E
STRAIN RELIEF TUBE
7
FIXTURE CONNECTOR
INNER WIRE
22
Loading...
+ 2 hidden pages