VISION3-KIT-H1-_
Installation Instructions for Vision 3 Halogen Kit
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electrical shock, exposure to
excessive UV radiation, or injury to persons:
- Use this fixture indoors only.
- Do not look directly at the lamp while the fixture is on.
- RISK OF FIRE: Use only the type of lamp and maximum
wattage indicated in this instruction manual.
- Never cover the halogen lamp with anything other than a
lamp shield provided by Edge Lighting and never place
flammable material close to the fixture.
- Never turn the fixture on and off by connecting and
disconnecting the halogen lamp.
- Do not touch the fixture head, shade or lamp shield while
the fixture is on. These surfaces may be VERY HOT.
- Do not touch lamp at anytime. Use a soft cloth instead as oil
from skin may damage lamp.
- It is normal for a new halogen lamp to produce minor
smoke when first turned on.
- Turn power off and allow to cool before replacing lamp.
IMPORTANT INFORMATION
- This product is ETL listed for indoor dry locations.
- This product is wall mounted only.
- This product can be dimmed with an electronic low voltage
dimmer.
SAVE THESE INSTRUCTIONS!
904-VISION3-KIT-H1-01
Install the Vision Housing
A
5
#8 SCREW
4
3
FOLDED LIP
1
PLASTER
SCREEN
STUD
NOTE: One of the housing lips needs to be installed to the
nearest stud of the desired location.
Mark the location on the stud where the housing will be
1:
mounted.
2: Place the plaster screen in front of the housing so that the
folded lips face outside.
3: Line up the screw holes on the plaster screen with the screw
holes of the housing and place one housing lip against the
marked stud.
4: Secure the housing along with the plaster screen to the stud
with the provided three #8 screws.
5: Use the other three #8 screws to secure the plaster screen
to the housing.
HOUSING LIP
1
![](/html/6f/6f3a/6f3af5af12d7d2a249fc75aee5eb6633fe6964f6b34cfebface6f2cdd90f2615/bg2.png)
B
HOUSING
CONDUIT
THERMAL
PROTECTOR
9
10
7
STUD
6: Remove a knock out to install the power line conduit.
7: Install the conduit and run the power line wires to the
housing.
8: Make sure that the housing is grounded in accordance with
local electrical codes.
9: Connect the white transformer wire to the neutral power
line wire with a wire nut.
10: Connect the black thermal protector wire to the hot power
line wire with a wire nut.
11: The black transformer wire is connected by default to the
other wire of the thermal protector.
7
TRANSFORMER
1: Mark 3" square(s) on drywall where the housing opening is
(are) located.
2: Cut out the marked square(s) and install the drywall.
D
TERMINAL
BLOCK
STRAIN RELIEF
DRYWALL
1
4
5
8
Install Drywall, Trim & Lamp
C
1
2
3: After installing drywall and finishing it, remove the cover on
the terminal block to expose the screws.
4: Loosen the two left Phillips screws on the terminal
block and the two on the strain relief (Do Not Remove).
5: Insert blue transformer wire through the strain relief
and one into each terminal block hole. Tighten the Phillips
screws on the terminal block and strain relief.
6: Replace the terminal block cover.
3"
3"
TRIM
COVER
2